Radiographic assessment of the peri-implant site.
cone beam computed tomography
diagnosis
peri‐implantitis
radiography
Journal
Periodontology 2000
ISSN: 1600-0757
Titre abrégé: Periodontol 2000
Pays: Denmark
ID NLM: 9313276
Informations de publication
Date de publication:
01 Jul 2024
01 Jul 2024
Historique:
revised:
09
04
2024
received:
10
02
2024
accepted:
12
05
2024
medline:
2
7
2024
pubmed:
2
7
2024
entrez:
2
7
2024
Statut:
aheadofprint
Résumé
While peri-implant mucositis relies solely on clinical parameters, radiological assessment becomes indispensable for diagnosing peri-implantitis. Intraoral radiography, with its simplicity of application, low radiation exposure, and adequate representation of peri-implant structures, stands out as the standard of care for both immediate and follow-up assessments. Standardization by custom-made radiologic splints allows for excellent comparability with previous images and allows for the determination of even small changes in contour and density of the peri-implant bone. Furthermore, other radiographic modalities like panoramic radiography and cone beam computed tomography (CBCT) may provide useful features for specific patients and clinical cases while also showing innate limitations. Beyond the assessment of the marginal peri-implant bone level as the crucial parameter of clinical relevance, radiologic assessment may reveal various other findings related to the prosthetic restoration itself, the precision of its fit to the implant, and the peri-implant soft and hard tissues. Since such findings can be crucial for the assessment of peri-implant health and the implants' prognosis, a systematic diagnostic evaluation pathway for a thorough assessment is recommended to extract all relevant information from radiologic imaging. This article also provides an overview of the clinical and chronological indications for different imaging modalities in peri-implant issues.
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2024 The Author(s). Periodontology 2000 published by John Wiley & Sons Ltd.
Références
Berglundh T, Armitage G, Araujo MG, et al. Peri‐implant diseases and conditions: consensus report of workgroup 4 of the 2017 world workshop on the classification of periodontal and peri‐implant diseases and conditions. J Clin Periodontol. 2018;45(Suppl 20):S286‐S291.
Herrera D, Berglundh T, Schwarz F, et al. Prevention and treatment of peri‐implant diseases‐the efp s3 level clinical practice guideline. J Clin Periodontol. 2023;50(Suppl 26):4‐76.
Gasser TJW, Papageorgiou SN, Eliades T, Hammerle CHF, Thoma DS. Interproximal contact loss at implant sites: a retrospective clinical study with a 10‐year follow‐up. Clin Oral Implants Res. 2022;33(5):482‐491.
Sheba M, Floriani F, Nimmo A, Ercoli C, Hosney S. Interproximal contact loss between implant restorations and adjacent natural teeth: a systematic review and meta‐analysis. J Prosthodont. 2023;33:313‐323.
Zitzmann NU. Occlusal load – a factor for implant failure? In: Heitz‐Mayfield LJA, Salvi GE, eds. Iti Treatment Guide Volume 13 Prevention and Management of Peri‐Implant Diseases. Quintessence Publishing; 2002.
Vollmer R, Vollmer M, Valentin R. Konuskronen auf implantaten. Implantol J. 2008;8.
Staubli N, Walter C, Schmidt JC, Weiger R, Zitzmann NU. Excess cement and the risk of peri‐implant disease ‐ a systematic review. Clin Oral Implants Res. 2017;28(10):1278‐1290.
Branemark PI, Hansson BO, Adell R, et al. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10‐year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1‐132.
Browaeys H, Defrancq J, Dierens MC, et al. A retrospective analysis of early and immediately loaded osseotite implants in cross‐arch rehabilitations in edentulous maxillas and mandibles up to 7 years. Clin Implant Dent Relat Res. 2013;15(3):380‐389.
Laurell L, Lundgren D. Marginal bone level changes at dental implants after 5 years in function: a meta‐analysis. Clin Implant Dent Relat Res. 2011;13(1):19‐28.
Molander B, Ahlqwist M, Grondahl HG, Hollender L. Agreement between panoramic and intra‐oral radiography in the assessment of marginal bone height. Dentomaxillofac Radiol. 1991;20(3):155‐160.
Oh TJ, Yoon J, Misch CE, Wang HL. The causes of early implant bone loss: myth or science? J Periodontol. 2002;73(3):322‐333.
Lang MS, Miyamoto T, Nunn ME. Validity of fractal analysis of implants in individuals with healthy and diseased peri‐implant mucosa. Clin Oral Implants Res. 2020;31(11):1039‐1046.
Schwarz F, Herten M, Sager M, Bieling K, Sculean A, Becker J. Comparison of naturally occurring and ligature‐induced peri‐implantitis bone defects in humans and dogs. Clin Oral Implants Res. 2007;18(2):161‐170.
Sahrmann P, Schoen P, Naenni N, Jung R, Attin T, Schmidlin PR. Peri‐implant bone density around implants of different lengths: a 3‐year follow‐up of a randomized clinical trial. J Clin Periodontol. 2017;44(7):762‐768.
Sluka B, Naenni N, Jung RE, Attin T, Schmidlin PR, Sahrmann P. Changes of radiopacity around implants of different lengths: five‐year follow‐up data of a randomized clinical trial. Clin Oral Implants Res. 2020;31(5):488‐494.
Albrektsson T, Jacobsson M. Bone‐metal interface in osseointegration. J Prosthet Dent. 1987;57(5):597‐607.
Sarmast ND, Wang HH, Soldatos NK, et al. A novel treatment decision tree and literature review of retrograde peri‐implantitis. J Periodontol. 2016;87(12):1458‐1467.
Roma LG, Lopes CB, Netto JNS, Miranda A, Pires FR. Idiopathic bone cavity: clinicopathologic features from a case series with emphasis on differential diagnosis of chronic apical periodontitis. J Endod. 2021;47(2):221‐225.
Vandamme JP. Letter: pearl necklace arteries. Nouv Presse Med. 1975;4(44):3141.
Trisi P, Berardini M, Falco A, Podaliri Vulpiani M, Perfetti G. Insufficient irrigation induces peri‐implant bone resorption: an in vivo histologic analysis in sheep. Clin Oral Implants Res. 2014;25(6):696‐701.
Nobre de AM, Malo PS, Oliveira SH. The influence of implant location and position characteristics on peri‐implant pathology. Eur J Prosthodont Restor Dent. 2014;22(3):125‐129.
Roccuzzo A, Imber JC, Salvi GE, Roccuzzo M. Peri‐implantitis as the consequence of errors in implant therapy. Periodontol 2000. 2023;92(1):350‐361.
Kuhl S, Zurcher S, Zitzmann NU, Filippi A, Payer M, Dagassan‐Berndt D. Detection of peri‐implant bone defects with different radiographic techniques ‐ a human cadaver study. Clin Oral Implants Res. 2016;27(5):529‐534.
Kuhnisch J, Anttonen V, Duggal MS, et al. Best clinical practice guidance for prescribing dental radiographs in children and adolescents: an eapd policy document. Eur Arch Paediatr Dent. 2020;21(4):375‐386.
Harris D, Horner K, Grondahl K, et al. A consensus workshop organized by the european association for osseointegration at the medical university of warsaw. Clin Oral Implants Res. 2012;23(11):1243‐1253.
Pelekos G, Acharya A, Tonetti MS, Bornstein MM. Diagnostic performance of cone beam computed tomography in assessing peri‐implant bone loss: a systematic review. Clin Oral Implants Res. 2018;29(5):443‐464.
Liao CW, Huang KJ, Chen JC, Kuo CW, Wu YY, Hsu JT. A prototype intraoral periapical sensor with high frame rates for a 2.5d periapical radiography system. Appl Bionics Biomech. 2019;2019:7987496.
Udupa H, Mah P, Dove SB, McDavid WD. Evaluation of image quality parameters of representative intraoral digital radiographic systems. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116(6):774‐783.
Bragger U. The development of digital subtraction radiography in dentistry–a review. Schweiz Monatsschr Zahnmed. 1988;98(11):1200‐1207.
Nicopoulou‐Karayianni K, Bragger U, Burgin W, Nielsen PM, Lang NP. Diagnosis of alveolar bone changes with digital subtraction images and conventional radiographs. An in vitro study. Oral Surg Oral Med Oral Pathol. 1991;72(2):251‐256.
De Bruyn H, Vandeweghe S, Ruyffelaert C, Cosyn J, Sennerby L. Radiographic evaluation of modern oral implants with emphasis on crestal bone level and relevance to peri‐implant health. Periodontol 2000. 2013;62(1):256‐270.
Lang NP, Berglundh T, Working Group 4 of Seventh European Workshop on P. Periimplant diseases: where are we now? – consensus of the seventh European workshop on periodontology. J Clin Periodontol. 2011;38(Suppl 11):178‐181.
Derks J, Schaller D, Hakansson J, Wennstrom JL, Tomasi C, Berglundh T. Peri‐implantitis – onset and pattern of progression. J Clin Periodontol. 2016;43(4):383‐388.
Dula K, Mini R, van der Stelt PF, Buser D. The radiographic assessment of implant patients: decision‐making criteria. Int J Oral Maxillofac Implants. 2001;16(1):80‐89.
Ekestubbe A, Thilander A, Grondahl K, Grondahl HG. Absorbed doses from computed tomography for dental implant surgery: comparison with conventional tomography. Dentomaxillofac Radiol. 1993;22(1):13‐17.
Batenburg RH, Stellingsma K, Raghoebar GM, Vissink A. Bone height measurements on panoramic radiographs: the effect of shape and position of edentulous mandibles. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1997;84(4):430‐435.
Samawi SS, Burke PH. Angular distortion in the orthopantomogram. Br J Orthod. 1984;11(2):100‐107.
Stramotas S, Geenty JP, Petocz P, Darendeliler MA. Accuracy of linear and angular measurements on panoramic radiographs taken at various positions in vitro. Eur J Orthod. 2002;24(1):43‐52.
von Arx T, Winzap‐Kalin C, Hanni S. Injuries to permanent teeth. Part 1: diagnosis of the tooth injury. Schweiz Monatsschr Zahnmed. 2005;115(2):133‐143.
Bragger U, Hugel‐Pisoni C, Burgin W, Buser D, Lang NP. Correlations between radiographic, clinical and mobility parameters after loading of oral implants with fixed partial dentures. A 2‐year longitudinal study. Clin Oral Implants Res. 1996;7(3):230‐239.
Bornstein MM, Horner K, Jacobs R. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research. Periodontol 2000. 2017;73(1):51‐72.
Jacobs R, Salmon B, Codari M, Hassan B, Bornstein MM. Cone beam computed tomography in implant dentistry: recommendations for clinical use. BMC Oral Health. 2018;18(1):88.
Benic GI, Sancho‐Puchades M, Jung RE, Deyhle H, Hammerle CH. In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography. Clin Oral Implants Res. 2013;24(4):378‐383.
Schulze R, Heil U, Gross D, et al. Artefacts in cbct: a review. Dentomaxillofac Radiol. 2011;40(5):265‐273.
Schwarz F, Sahm N, Mihatovic I, Golubovic V, Becker J. Surgical therapy of advanced ligature‐induced peri‐implantitis defects: cone‐beam computed tomographic and histological analysis. J Clin Periodontol. 2011;38(10):939‐949.
Bender P, Salvi GE, Buser D, Sculean A, Bornstein MM. Correlation of three‐dimensional radiologic data with subsequent treatment approach in patients with peri‐implantitis: a retrospective analysis. Int J Periodontics Restorative Dent. 2017;37(4):481‐489.
Schriber M, Yeung AWK, Suter VGA, Buser D, Leung YY, Bornstein MM. Cone beam computed tomography artefacts around dental implants with different materials influencing the detection of peri‐implant bone defects. Clin Oral Implants Res. 2020;31(7):595‐606.
Golubovic V, Mihatovic I, Becker J, Schwarz F. Accuracy of cone‐beam computed tomography to assess the configuration and extent of ligature‐induced peri‐implantitis defects. A Pilot Study. Oral Maxillofac Surg. 2012;16(4):349‐354.
Wang D, Kunzel A, Golubovic V, et al. Accuracy of peri‐implant bone thickness and validity of assessing bone augmentation material using cone beam computed tomography. Clin Oral Investig. 2013;17(6):1601‐1609.
Hung K, Hui L, Yeung AWK, Scarfe WC, Bornstein MM. Image retake rates of cone beam computed tomography in a dental institution. Clin Oral Investig. 2020;24(12):4501‐4510.
Charuakkra A, Mahasantipiya P, Lehtinen A, Koivisto J, Jarnstedt J. Comparison of subjective image analysis and effective dose between low‐dose cone‐beam computed tomography machines. Dentomaxillofac Radiol. 2023;52(2):20220176.
Gaeta‐Araujo H, Leite AF, Vasconcelos KF, Jacobs R. Two decades of research on cbct imaging in dmfr ‐ an appraisal of scientific evidence. Dentomaxillofac Radiol. 2021;50(4):20200367.
Ludlow JB, Timothy R, Walker C, Hunter R, Benavides E, Samuelson DB. Correction to effective dose of dental CBCT–a meta analysis of published data and additional data for nine CBCT units. Dentomaxillofac Radiol. 2015;44(7):20159003.
Kaasalainen T, Ekholm M, Siiskonen T, Kortesniemi M. Dental cone beam ct: an updated review. Phys Med. 2021;88:193‐217.
Dula K, Benic GI, Bornstein M, et al. Sadmfr guidelines for the use of cone‐beam computed tomography/digital volume tomography. Swiss Dent J. 2015;125(9):945‐953.
Dula K, Bornstein MM, Buser D, et al. Sadmfr guidelines for the use of cone‐beam computed tomography/ digital volume tomography. Swiss Dent J. 2014;124(11):1169‐1183.
Pirih FQ, Hiyari S, Barroso AD, et al. Ligature‐induced peri‐implantitis in mice. J Periodontal Res. 2015;50(4):519‐524.
Su K, Zhou Y, Hossaini‐Zadeh M, Du J. Effects of implant buccal distance on peri‐implant strain: a micro‐ct based finite element analysis. J Mech Behav Biomed Mater. 2021;116:104325.
Yeung AWK, AlHadidi A, Vyas R, Bornstein MM, Watanabe H, Tanaka R. Non‐ionizing diagnostic imaging modalities for visualizing health and pathology of periodontal per‐implant tissues. Accepted for publication.
Park W, Schwendicke F, Krois J, Huh JK, Lee JH. Identification of dental implant systems using a large‐scale multicenter data set. J Dent Res. 2023;102(7):727‐733.
Troiano G, Fanelli F, Rapani A, et al. Can radiomic features extracted from intra‐oral radiographs predict physiological bone remodelling around dental implants? A Hypothesis‐Generating Study. J Clin Periodontol. 2023;50(7):932‐941.