A golgi targeting viscosity rotor for cancer diagnosis in living cells and tissues.


Journal

Talanta
ISSN: 1873-3573
Titre abrégé: Talanta
Pays: Netherlands
ID NLM: 2984816R

Informations de publication

Date de publication:
29 Jun 2024
Historique:
received: 18 04 2024
revised: 15 06 2024
accepted: 29 06 2024
medline: 3 7 2024
pubmed: 3 7 2024
entrez: 2 7 2024
Statut: aheadofprint

Résumé

Unveiling the intricate relationship between cancer and Golgi viscosity remains an arduous endeavor, primarily due to the lack of Golgi-specific fluorescent probes tailored for viscosity measurement. Considering this formidable obstacle, we have triumphed over the challenge by devising a bespoke Golgi-specific viscosity probe, aptly named GOL-V. This ingenious innovation comprises the viscosity rotor BODIPY intricately tethered to the Golgi-targeting moiety benzsulfamide. GOL-V exhibits remarkable sensitivity to fluctuations in viscosity, the fluorescence intensity of GOL-V increased 114-fold when the viscosity value was increased from 2.63 to 937.28 cP. Owing to its remarkable capacity to suppress the TICT state under conditions of heightened viscosity. Moreover, its efficacy in sensitively monitoring Golgi viscosity alterations within living cells is also very significant. Astonishingly, our endeavors have culminated in not only the visualization of Golgi viscosity at the cellular and tissue levels but also in the clinical tissue samples procured from cancer patients. Harnessing the prowess of GOL-V, we have successfully demonstrated that Golgi viscosity could serve as a discerning marker for detecting the presence of cancer. The convergence of these exceptional attributes firmly establishes GOL-V as an immensely potent instrument, holding immense potential in the realm of cancer diagnosis.

Identifiants

pubmed: 38955104
pii: S0039-9140(24)00876-2
doi: 10.1016/j.talanta.2024.126497
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

126497

Informations de copyright

Copyright © 2024. Published by Elsevier B.V.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Xiaodong Wang (X)

Key Laboratory of Magnetic Molecules and Magnetic Information Materials of Ministry of Education & School of Chemistry and Materials Science of Shanxi Normal University, Taiyuan, 030031, PR China. Electronic address: 20220069@sxnu.edu.cn.

Xiaoping Li (X)

Key Laboratory of Magnetic Molecules and Magnetic Information Materials of Ministry of Education & School of Chemistry and Materials Science of Shanxi Normal University, Taiyuan, 030031, PR China.

Zonghui Liu (Z)

Key Laboratory of Magnetic Molecules and Magnetic Information Materials of Ministry of Education & School of Chemistry and Materials Science of Shanxi Normal University, Taiyuan, 030031, PR China.

Yating Meng (Y)

Shanxi Medical University, Taiyuan, 030001, PR China.

Xiaofang Fan (X)

Department of Pathology, Shanxi Provincial People's Hospital, Taiyuan, 030012, PR China.

Hui Wang (H)

Key Laboratory of Magnetic Molecules and Magnetic Information Materials of Ministry of Education & School of Chemistry and Materials Science of Shanxi Normal University, Taiyuan, 030031, PR China.

Jisheng Nie (J)

Shanxi Medical University, Taiyuan, 030001, PR China. Electronic address: niejisheng@126.com.

Bingchun Xue (B)

Key Laboratory of Magnetic Molecules and Magnetic Information Materials of Ministry of Education & School of Chemistry and Materials Science of Shanxi Normal University, Taiyuan, 030031, PR China. Electronic address: bcxue@sxnu.edu.cn.

Classifications MeSH