The effect of the infusion connection point on intravenous multi-infusion drug delivery to premature neonates - Use of standard concentration infusions of critical medications.

Catecholamine Continuous infusion Dosing error Infusion pump Intravenous infusion Neonatal intensive care Neonate

Journal

European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V
ISSN: 1873-3441
Titre abrégé: Eur J Pharm Biopharm
Pays: Netherlands
ID NLM: 9109778

Informations de publication

Date de publication:
02 Jul 2024
Historique:
received: 08 05 2024
revised: 27 06 2024
accepted: 01 07 2024
medline: 5 7 2024
pubmed: 5 7 2024
entrez: 4 7 2024
Statut: aheadofprint

Résumé

Sick neonates with haemodynamic instability often require complex medication regimens, which may result in the connection of a catecholamine infusion distally. This increases the dead volume of the infusion system, extending the time to medication delivery. This study evaluated the effects of body weight, and infusion connection point on the delivery rate of two medications infused through a multi-infusion system at infusion rates suitable for extremely and very low birth weight (ELBW and VLBW) neonates. An infusion system consisting of six infusions was used to investigate time to delivery, drug concentration at time to delivery and quantity of adrenaline and dopamine administered by intravenous infusions at infusion rates suitable for premature neonates. In an ELBW neonate model, the measured adrenaline and dopamine concentration at 12 T was higher than expected (66.7 (7.5)% (mean (SD)) and 68.0 (4.4)%, respectively, P < 0.001). At the calculated time to delivery, neither drug reached target concentration. In a VLBW neonate model, the measured adrenaline and dopamine concentration at 12 T was higher than expected (92.2 (7.1)% and 97.1 (3.1)%, respectively, P < 0.001). Adrenaline reached target concentration at 27 (11) min and dopamine at 56 (12) min, times significantly shorter than calculated. The measured quantity of adrenaline and dopamine delivered was lower (P < 0.001) than calculated in all tested combinations except adrenaline at proximal connection (97.2 (3.4)%, P = 0.097) in the VLBW neonate model CONCLUSIONS: Using the most proximal available infusion connection considerably improves drug delivery times and drug doses delivered, which is critical during the administration of short-acting cardiovascular medications.

Sections du résumé

BACKGROUND BACKGROUND
Sick neonates with haemodynamic instability often require complex medication regimens, which may result in the connection of a catecholamine infusion distally. This increases the dead volume of the infusion system, extending the time to medication delivery. This study evaluated the effects of body weight, and infusion connection point on the delivery rate of two medications infused through a multi-infusion system at infusion rates suitable for extremely and very low birth weight (ELBW and VLBW) neonates.
METHODS METHODS
An infusion system consisting of six infusions was used to investigate time to delivery, drug concentration at time to delivery and quantity of adrenaline and dopamine administered by intravenous infusions at infusion rates suitable for premature neonates.
RESULTS RESULTS
In an ELBW neonate model, the measured adrenaline and dopamine concentration at 12 T was higher than expected (66.7 (7.5)% (mean (SD)) and 68.0 (4.4)%, respectively, P < 0.001). At the calculated time to delivery, neither drug reached target concentration. In a VLBW neonate model, the measured adrenaline and dopamine concentration at 12 T was higher than expected (92.2 (7.1)% and 97.1 (3.1)%, respectively, P < 0.001). Adrenaline reached target concentration at 27 (11) min and dopamine at 56 (12) min, times significantly shorter than calculated. The measured quantity of adrenaline and dopamine delivered was lower (P < 0.001) than calculated in all tested combinations except adrenaline at proximal connection (97.2 (3.4)%, P = 0.097) in the VLBW neonate model CONCLUSIONS: Using the most proximal available infusion connection considerably improves drug delivery times and drug doses delivered, which is critical during the administration of short-acting cardiovascular medications.

Identifiants

pubmed: 38964521
pii: S0939-6411(24)00217-0
doi: 10.1016/j.ejpb.2024.114391
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

114391

Informations de copyright

Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Kamelia Krysiak (K)

School of Pharmacy and Biomolecular Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland.

Naomi McCallion (N)

The Rotunda Hospital, Dublin, Ireland; Department of Paediatrics, RCSI University of Medicine and Health Sciences, Dublin, Ireland.

Brian Cleary (B)

School of Pharmacy and Biomolecular Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland; The Rotunda Hospital, Dublin, Ireland.

Fiona O'Brien (F)

School of Pharmacy and Biomolecular Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland. Electronic address: fionaobrien@rcsi.ie.

Classifications MeSH