Accuracy and reliability for estimating jaw functional range of motion.

Accuracy Head Jaw Kinematics Reliability

Journal

Gait & posture
ISSN: 1879-2219
Titre abrégé: Gait Posture
Pays: England
ID NLM: 9416830

Informations de publication

Date de publication:
29 Jun 2024
Historique:
received: 22 02 2024
revised: 27 05 2024
accepted: 19 06 2024
medline: 7 7 2024
pubmed: 7 7 2024
entrez: 6 7 2024
Statut: aheadofprint

Résumé

Three dimensional (3D) kinematic analysis based on motion capture can study synchronized data from the integrated jaw and neck motor system. Jaw function is commonly estimated on linear outcome variables of motion range. By combining jaw border movements in three planes the functional range of motion could be described by movement area and volume measures. Can we ensure the accuracy, test-retest reliability, and intra-individual variability with 3D kinematic analysis for estimating jaw functional range of motion (ROM), including jaw movement area and volume and jaw and head linear measures? Accuracy was estimated by applying the method to a set of beakers with known volume, based on the percentage deviation and Pearson correlation coefficient between target and estimated values. Test-retest reliability was then analysed on maximum jaw movements performed in a pre-determined movement sequence by 17 pain-free participants (25.4 years ± 2.4) to estimate jaw functional ROM. Intraclass correlation coefficients (ICC) were calculated, and Bland-Altman plots were constructed. Coefficient of variation (CV) tested the within session reliability. The accuracy in volume and area measurements were high with a percentage deviation (0.03±0.59) and (1.2±0.45), respectively, with a strong linear relationship (R The study with 3D kinematic analysis of jaw functional ROM, provides a methodological basis for accurate and reliable measurements. The study presents a new way to estimate jaw functional ROM measures, useful for evaluation in clinical intervention, for instance in pain and jaw dysfunction. Moreover, the natural biological movement variability and the complexity of the interplay of jaw-head movement will be emphasised.

Sections du résumé

BACKGROUND BACKGROUND
Three dimensional (3D) kinematic analysis based on motion capture can study synchronized data from the integrated jaw and neck motor system. Jaw function is commonly estimated on linear outcome variables of motion range. By combining jaw border movements in three planes the functional range of motion could be described by movement area and volume measures.
RESEARCH QUESTION OBJECTIVE
Can we ensure the accuracy, test-retest reliability, and intra-individual variability with 3D kinematic analysis for estimating jaw functional range of motion (ROM), including jaw movement area and volume and jaw and head linear measures?
METHODS METHODS
Accuracy was estimated by applying the method to a set of beakers with known volume, based on the percentage deviation and Pearson correlation coefficient between target and estimated values. Test-retest reliability was then analysed on maximum jaw movements performed in a pre-determined movement sequence by 17 pain-free participants (25.4 years ± 2.4) to estimate jaw functional ROM. Intraclass correlation coefficients (ICC) were calculated, and Bland-Altman plots were constructed. Coefficient of variation (CV) tested the within session reliability.
RESULTS RESULTS
The accuracy in volume and area measurements were high with a percentage deviation (0.03±0.59) and (1.2±0.45), respectively, with a strong linear relationship (R
SIGNIFICANCE CONCLUSIONS
The study with 3D kinematic analysis of jaw functional ROM, provides a methodological basis for accurate and reliable measurements. The study presents a new way to estimate jaw functional ROM measures, useful for evaluation in clinical intervention, for instance in pain and jaw dysfunction. Moreover, the natural biological movement variability and the complexity of the interplay of jaw-head movement will be emphasised.

Identifiants

pubmed: 38970930
pii: S0966-6362(24)00202-9
doi: 10.1016/j.gaitpost.2024.06.017
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

280-286

Informations de copyright

Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of Competing Interest The authors declare that they have no competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Evelina Nilsson (E)

Department of Odontology, Clinical Oral Physiology, Umeå University, Umeå 901 87, Sweden. Electronic address: evelina.nilsson@umu.se.

Helena Grip (H)

Department of Diagnostics and Intervention, Umeå University, Umeå 901 87, Sweden. Electronic address: helena.grip@umu.se.

Catharina Österlund (C)

Department of Odontology, Clinical Oral Physiology, Umeå University, Umeå 901 87, Sweden. Electronic address: catharina.osterlund@umu.se.

Classifications MeSH