Prospective longitudinal cohort study of quantitative muscle magnetic resonance imaging in a healthy control population.
longitudinal cohort study
muscle diffusion tensor imaging
skeletal muscle
tractography
Journal
NMR in biomedicine
ISSN: 1099-1492
Titre abrégé: NMR Biomed
Pays: England
ID NLM: 8915233
Informations de publication
Date de publication:
10 Jul 2024
10 Jul 2024
Historique:
revised:
03
06
2024
received:
23
01
2024
accepted:
18
06
2024
medline:
10
7
2024
pubmed:
10
7
2024
entrez:
10
7
2024
Statut:
aheadofprint
Résumé
Quantitative muscle magnetic resonance imaging (qMRI) is a valuable methodology for assessing muscular injuries and neuromuscular disorders. Notably, muscle diffusion tensor imaging (DTI) gives insights into muscle microstructural and macrostructural characteristics. However, the long-term reproducibility and robustness of these measurements remain relatively unexplored. The purpose of this prospective longitudinal cohort study was to assess the long-term robustness and range of variation of qMRI parameters, especially DTI metrics, in the lower extremity muscles of healthy controls under real-life conditions. Twelve volunteers (seven females, age 44.1 ± 12.1 years, body mass index 23.3 ± 2.0 kg/m
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e5214Subventions
Organisme : Sanofi
ID : SGZ-2019-12541
Organisme : DFG
ID : 122679504
Organisme : DFG
ID : SFB874
Organisme : DFG
ID : TP-A5
Organisme : Ruhr-University Bochum
ID : K139-20
Organisme : Ruhr-University Bochum
ID : K174N-22-A
Organisme : Ruhr-University Bochum
ID : K-144-20
Organisme : Heimer Foundation
Organisme : Applied and Engineering Sciences (AES) Dutch Research Council (NWO)
ID : 18929
Informations de copyright
© 2024 The Author(s). NMR in Biomedicine published by John Wiley & Sons Ltd.
Références
Giraudo C, Motyka S, Weber M, et al. Normalized STEAM‐based diffusion tensor imaging provides a robust assessment of muscle tears in football players: preliminary results of a new approach to evaluate muscle injuries. Eur Radiol. 2018;28(7):2882‐2889. doi:10.1007/s00330‐017‐5218‐9
Marty B, Baudin P‐Y, de Almeida Araujo EC, Fromes Y, Wahbi K, Reyngoudt H. Assessment of extracellular volume fraction in Becker muscular dystrophy by using MR fingerprinting. Radiology. 2023;307(3):e221115. doi:10.1148/radiol.221115
Grimm A, Meyer H, Nickel MD, et al. Repeatability of Dixon magnetic resonance imaging and magnetic resonance spectroscopy for quantitative muscle fat assessments in the thigh. J Cachexia Sarcopenia Muscle. 2018;9(6):1093‐1100. doi:10.1002/jcsm.12343
Vincenten SCC, Mul K, van As D, et al. Five‐year follow‐up study on quantitative muscle magnetic resonance imaging in facioscapulohumeral muscular dystrophy: the link to clinical outcome. J Cachexia Sarcopenia Muscle. 2023;14(4):1695‐1706. doi:10.1002/jcsm.13250
Marty B, Reyngoudt H, Boisserie J‐M, et al. Water‐fat separation in MR fingerprinting for quantitative monitoring of the skeletal muscle in neuromuscular disorders. Radiology. 2021;300(3):652‐660. doi:10.1148/radiol.2021204028
Nassar J, Trabelsi A, Amer R, et al. Estimation of subvoxel fat infiltration in neurodegenerative muscle disorders using quantitative multi‐T2 analysis. NMR Biomed. 2023;36(9):1‐14. doi:10.1002/nbm.4947
Schlaeger S, Weidlich D, Zoffl A, et al. Beyond mean value analysis—a voxel‐based analysis of the quantitative MR biomarker water T2 in the presence of fatty infiltration in skeletal muscle tissue of patients with neuromuscular diseases. NMR Biomed. 2022;35(12):e4805. doi:10.1002/nbm.4805
Monte JR, Hooijmans MT, Froeling M, et al. Diffusion tensor imaging and quantitative T2 mapping to monitor muscle recovery following hamstring injury. NMR Biomed. 2023;36(7):1‐13. doi:10.1002/nbm.4902
Forsting J, Rohm M, Froeling M, et al. Quantitative muscle MRI captures early muscle degeneration in calpainopathy. Sci Rep. 2022;12(1):1‐10. doi:10.1038/s41598‐022‐23972‐6
Cameron D, Abbassi‐Daloii T, Heezen LGM, et al. Diffusion‐tensor magnetic resonance imaging captures increased skeletal muscle fibre diameters in Becker muscular dystrophy. J Cachexia Sarcopenia Muscle. 2023;14(3):1546‐1557. doi:10.1002/jcsm.13242
Otto LAM, van der Pol WL, Schlaffke L, et al. Quantitative MRI of skeletal muscle in a cross‐sectional cohort of patients with spinal muscular atrophy types 2 and 3. NMR Biomed. 2020;33:1‐13. doi:10.1002/nbm.4357
Hooijmans MT, Habets LE, van den Berg‐Faay SAM, et al. Multi‐parametric quantitative magnetic resonance imaging of the upper arm muscles of patients with spinal muscular atrophy. NMR Biomed. 2022;35(7):e4696. doi:10.1002/nbm.4696
Cameron D, Reiter DA, Adelnia F, et al. Age‐related changes in human skeletal muscle microstructure and architecture assessed by diffusion‐tensor magnetic resonance imaging and their association with muscle strength. Aging Cell. 2023;22(7):1‐15. doi:10.1111/acel.13851
Wang F, Fang S, Li J, et al. Correlation analysis of quantitative MRI measurements of thigh muscles with histopathology in patients with idiopathic inflammatory myopathy. Eur Radiol Exp. 2023;7(1):51. doi:10.1186/s41747‐023‐00350‐z
Aeles J, Bolsterlee B, Kelp NY, Dick TJM, Hug F. Regional variation in lateral and medial gastrocnemius muscle fibre lengths obtained from diffusion tensor imaging. J Anat. 2022;240(1):131‐144. doi:10.1111/joa.13539
Enax‐Krumova E, Forsting J, Rohm M, et al. Quantitative muscle magnetic resonance imaging depicts microstructural abnormalities but no signs of inflammation or dystrophy in post‐COVID19 condition. Eur J Neurol. 2023;30(4):970‐981. doi:10.1111/ene.15709
Chianca V, Albano D, Rizzo S, Maas M, Sconfienza LM, Del Grande F. Inter‐vendor and inter‐observer reliability of diffusion tensor imaging in the musculoskeletal system: a multiscanner MR study. Insights Imaging. 2023;14(1):32. doi:10.1186/s13244‐023‐01374‐0
Monte JR, Hooijmans MT, Froeling M, et al. The repeatability of bilateral diffusion tensor imaging (DTI) in the upper leg muscles of healthy adults. Eur Radiol. 2020;30(3):1709‐1718. doi:10.1007/s00330‐019‐06403‐5
Bolsterlee B, Souza AD, Herbert RD. Reliability and robustness of muscle architecture measurements obtained using diffusion tensor imaging with anatomically constrained tractography. J Biomech. 2019;86:71‐78. doi:10.1016/j.jbiomech.2019.01.043
Fouré A, Ogier AC, Le Troter A, et al. Diffusion properties and 3D architecture of human lower leg muscles assessed with and tractography: reproducibility and sensitivity to sex difference and intramuscular variability. Radiology. 2018;287(2):592‐607. doi:10.1148/radiol.2017171330
Schlaffke L, Rehmann R, Rohm M, et al. Multi‐center evaluation of stability and reproducibility of quantitative MRI measures in healthy calf muscles. NMR Biomed. 2019;32(9):e4119. doi:10.1002/nbm.4119
Forsting J, Rehmann R, Rohm M, et al. Robustness and stability of volume‐based tractography in a multicenter setting. NMR Biomed. 2022;35(7):1‐13. doi:10.1002/nbm.4707
Farrow M, Biglands J, Tanner SF, et al. The effect of ageing on skeletal muscle as assessed by quantitative MR imaging: an association with frailty and muscle strength. Aging Clin Exp Res. 2021;33(2):291‐301. doi:10.1007/s40520‐020‐01530‐2
Froeling M. QMRTools: a Mathematica toolbox for quantitative MRI analysis. J Open Source Softw. 2019;4(38):1204. doi:10.21105/joss.01204
Leemans A, Jones DK. The B‐matrix must be rotated when correcting for subject motion in DTI data. Magn Reson Med. 2009;61(6):1336‐1349. doi:10.1002/mrm.21890
Reeder SB, Pineda AR, Wen Z, et al. Iterative decomposition of water and fat with echo asymmetry and least‐squares estimation (IDEAL): application with fast spin‐echo imaging. Magn Reson Med. 2005;54:636‐644. doi:10.1002/mrm.20624
Marty B, Baudin P, Reyngoudt H, et al. Simultaneous muscle water T2 and fat fraction mapping using transverse relaxometry with stimulated echo compensation. NMR Biomed. 2016;29(4):431‐443. doi:10.1002/nbm.3459
Keene KR, Beenakker JM, Hooijmans MT, et al. T2 relaxation‐time mapping in healthy and diseased skeletal muscle using extended phase graph algorithms. Magn Reson Med. 2020;84(5):2656‐2670. doi:10.1002/mrm.28290
Rohm M, Markmann M, Forsting J, Rehmann R, Froeling M, Schlaffke L. 3D automated segmentation of lower leg muscles using machine learning on a heterogeneous dataset. Diagnostics. 2021;11:1747. doi:10.3390/diagnostics11101747
Klein S, Staring M, Murphy K, Viergever MA, Pluim J. elastix: a toolbox for intensity‐based medical image registration. IEEE Trans Med Imaging. 2010;29(1):196‐205. doi:10.1109/TMI.2009.2035616
Veraart J, Novikov DS, Christiaens D, Ades‐Aron B, Sijbers J, Fieremans E. Denoising of diffusion MRI using random matrix theory. Neuroimage. 2016;142:394‐406. doi:10.1016/j.neuroimage.2016.08.016
Veraart J, Sijbers J, Sunaert S, Leemans A, Jeurissen B. Weighted linear least squares estimation of diffusion MRI parameters: strengths, limitations, and pitfalls. Neuroimage. 2013;81:335‐346. doi:10.1016/j.neuroimage.2013.05.028
Forsting J, Rehmann R, Froeling M, Vorgerd M, Tegenthoff M, Schlaffke L. Diffusion tensor imaging of the human thigh: consideration of DTI‐based fiber tracking stop criteria. Magn Reson Mater Physics, Biol Med. 2020;33(3):343‐355. doi:10.1007/s10334‐019‐00791‐x
Forsting J, Rehmann R, Rohm M, Froeling M, Schlaffke L. Evaluation of interrater reliability of different muscle segmentation techniques in diffusion tensor imaging. NMR Biomed. 2021;34(2):1‐11. doi:10.1002/nbm.4430
Oudeman J, Mazzoli V, Marra MA, Nicolay K, Maas M. A novel diffusion‐tensor MRI approach for skeletal muscle fascicle length measurements. Physiol Rep. 2016;4(24):e13012. doi:10.14814/phy2.13012
Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155‐163. doi:10.1016/j.jcm.2016.02.012
Furlan L, Sterr A. The applicability of standard error of measurement and minimal detectable change to motor learning research—a behavioral study. Front Hum Neurosci. 2018;12:95. doi:10.3389/fnhum.2018.00095
Muckelt PE, Warner MB, Cheliotis‐James T, et al. Protocol and reference values for minimal detectable change of MyotonPRO and ultrasound imaging measurements of muscle and subcutaneous tissue. Sci Rep. 2022;12(1):13654. doi:10.1038/s41598‐022‐17507‐2
Hooijmans MT, Damon BM, Froeling M, et al. Evaluation of skeletal muscle DTI in patients with duchenne muscular dystrophy. NMR Biomed. 2015;28(11):1589‐1597. doi:10.1002/nbm.3427
Atkinson G, Nevill A. Comment on the use of concordance correlation to assess the agreement between two variables. Biometrics. 1997;53(2):775‐777.
Rehmann R, Froeling M, Rohm M, et al. Diffusion tensor imaging reveals changes in non‐fat infiltrated muscles in late‐onset Pompe disease. Muscle Nerve. 2020;62(4):541‐549. doi:10.1002/mus.27021
Tous C, Jodoin A, Grabs D, Van Houten E, Bureau NJ. Intersession repeatability of diffusion‐tensor imaging in the supraspinatus and the infraspinatus muscles of volunteers. J Magn Reson Imaging. 2023;57(5):1414‐1422. doi:10.1002/jmri.28424
Liljequist D, Elfving B, Skavberg Roaldsen K. Intraclass correlation—a discussion and demonstration of basic features. PLoS One. 2019;14(7):e0219854. doi:10.1371/journal.pone.0219854
Rehmann R, Schneider‐Gold C, Froeling M, et al. Diffusion tensor imaging shows differences between myotonic dystrophy type 1 and type 2. J Neuromuscul Dis. 2021;8:949‐962. doi:10.3233/JND‐210660
Nguyen H‐T, Grenier T, Leporq B, et al. Quantitative magnetic resonance imaging assessment of the quadriceps changes during an extreme mountain ultramarathon. Med Sci Sport Exerc. 2021;53(4):869‐881. doi:10.1249/MSS.0000000000002535
Hooijmans MT, Monte JRC, Froeling M, et al. Quantitative MRI reveals microstructural changes in the upper leg muscles after running a marathon. J Magn Reson Imaging. 2020;52(2):407‐417. doi:10.1002/jmri.27106
Heskamp L, Ogier A, Bendahan D, Heerschap A. Whole‐muscle fat analysis identifies distal muscle end as disease initiation site in facioscapulohumeral muscular dystrophy. Commun Med. 2022;2(1):1‐12. doi:10.1038/s43856‐022‐00217‐1