Impact of terminal cleaning in rooms previously occupied by patients with healthcare-associated infections.
Cross Infection
/ microbiology
Humans
Patients' Rooms
Methicillin-Resistant Staphylococcus aureus
/ isolation & purification
Clostridioides difficile
/ isolation & purification
Housekeeping, Hospital
Acinetobacter baumannii
/ isolation & purification
Infection Control
/ methods
Vancomycin-Resistant Enterococci
/ isolation & purification
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2024
2024
Historique:
received:
18
09
2023
accepted:
23
05
2024
medline:
10
7
2024
pubmed:
10
7
2024
entrez:
10
7
2024
Statut:
epublish
Résumé
Healthcare associated infections (HAIs) are costly but preventable. A limited understanding of the effects of environmental cleaning on the riskiest HAI associated pathogens is a current challenge in HAI prevention. This project aimed to quantify the effects of terminal hospital cleaning practices on HAI pathogens via environmental sampling in three hospitals located throughout the United States. Surfaces were swabbed from 36 occupied patient rooms with a laboratory-confirmed, hospital- or community-acquired infection of at least one of the four pathogens of interest (i.e., Acinetobacter baumannii (A. baumannii), methicillin resistant Staphylococcus aureus (MRSA), vancomycin resistant Enterococcus faecalis/faecium (VRE), and Clostridioides difficile (C. difficile)). Six nonporous, high touch surfaces (i.e., chair handrail, bed handrail, nurse call button, desk surface, bathroom counter near the sink, and a grab bar near the toilet) were sampled in each room for Adenosine Triphosphate (ATP) and the four pathogens of interest before and after terminal cleaning. The four pathogens of interest were detected on surfaces before and after terminal cleaning, but their levels were generally reduced. Overall, C. difficile was confirmed on the desk (n = 2), while MRSA (n = 24) and VRE (n = 25) were confirmed on all surface types before terminal cleaning. After cleaning, only MRSA (n = 6) on bed handrail, chair handrail, and nurse call button and VRE (n = 5) on bathroom sink, bed handrail, nurse call button, toilet grab bar, and C. difficile (n = 1) were confirmed. At 2 of the 3 hospitals, pathogens were generally reduced by >99% during terminal cleaning. One hospital showed that VRE increased after terminal cleaning, MRSA was reduced by 73% on the nurse call button, and VRE was reduced by only 50% on the bathroom sink. ATP detections did not correlate with any pathogen concentration. This study highlights the importance of terminal cleaning and indicates room for improvement in cleaning practices to reduce surface contamination throughout hospital rooms.
Identifiants
pubmed: 38985740
doi: 10.1371/journal.pone.0305083
pii: PONE-D-23-27473
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0305083Informations de copyright
Copyright: © 2024 Verhougstraete et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Déclaration de conflit d'intérêts
The authors have declared that no competing interests exist.