Utility of salivary cortisol and cortisone in the diagnostics of adrenal insufficiency.

Adrenal insufficiency cosyntropin test diagnostic performance salivary cortisol

Journal

The Journal of clinical endocrinology and metabolism
ISSN: 1945-7197
Titre abrégé: J Clin Endocrinol Metab
Pays: United States
ID NLM: 0375362

Informations de publication

Date de publication:
12 Jul 2024
Historique:
received: 24 04 2024
revised: 10 07 2024
accepted: 10 07 2024
medline: 12 7 2024
pubmed: 12 7 2024
entrez: 12 7 2024
Statut: aheadofprint

Résumé

Salivary cortisol (sa-cortisol) and salivary cortisone (sa-cortisone) correlate well with serum cortisol (s-cortisol) but validated reference ranges for healthy individuals are lacking. To establish cutoff levels for sa-cortisol and cortisone following cosyntropin testing, and assess their diagnostic utility in adrenal insufficiency (AI). Steroids in saliva were assayed using liquid-chromatography tandem-mass-spectrometry (LCMS/MS) before and after administration of 250µg cosyntropin test in 128 healthy subjects (16 on oral estrogens) and 59 patients with suspected AI, of whom 26 were diagnosed with AI with conventional serum cortisol criteria. The cutoff level for AI was defined as the 2.5th centile in healthy subjects not receiving estrogens. Performance was evaluated by calculating diagnostic accuracy and analyzing receiver operating characteristic-curves. The sa-cortisol cutoff 60 minutes after cosyntropin stimulation was 12.6 nmol/L (accuracy 89%, sensitivity 85%, and specificity 90%). Sa-cortisone and the sum of sa-cortisol and cortisone exhibited poorer diagnostic performance than sa-cortisol. The correlation between sa-cortisol and s-cortisol was best described by a model incorporating two regression lines (R2 = 0.80). Segmented regression analysis identified a breakpoint at sa-cortisol 9.7 nmol/L and s-cortisol 482 nmol/L, likely corresponding to saturation of cortisol binding globulin (CBG). Healthy subjects on oral estrogens demonstrated a linear agreement between s- and sa-cortisol through all measurements. Seventeen healthy subjects repeated the test, with similar outcome, but reproducibility in terms of intraclass coefficient and correlation was poor. Sa-cortisol in cosyntropin-test has high diagnostic accuracy in detecting adrenal insufficiency, and is particularly useful in women on oral estrogens. A sa-cortisol > 12.6 nmol/L assayed with LCMS/MS 60 min after 250µg cosyntropin is normal.

Sections du résumé

BACKGROUND BACKGROUND
Salivary cortisol (sa-cortisol) and salivary cortisone (sa-cortisone) correlate well with serum cortisol (s-cortisol) but validated reference ranges for healthy individuals are lacking.
OBJECTIVE OBJECTIVE
To establish cutoff levels for sa-cortisol and cortisone following cosyntropin testing, and assess their diagnostic utility in adrenal insufficiency (AI).
METHODS METHODS
Steroids in saliva were assayed using liquid-chromatography tandem-mass-spectrometry (LCMS/MS) before and after administration of 250µg cosyntropin test in 128 healthy subjects (16 on oral estrogens) and 59 patients with suspected AI, of whom 26 were diagnosed with AI with conventional serum cortisol criteria. The cutoff level for AI was defined as the 2.5th centile in healthy subjects not receiving estrogens. Performance was evaluated by calculating diagnostic accuracy and analyzing receiver operating characteristic-curves.
RESULTS RESULTS
The sa-cortisol cutoff 60 minutes after cosyntropin stimulation was 12.6 nmol/L (accuracy 89%, sensitivity 85%, and specificity 90%). Sa-cortisone and the sum of sa-cortisol and cortisone exhibited poorer diagnostic performance than sa-cortisol. The correlation between sa-cortisol and s-cortisol was best described by a model incorporating two regression lines (R2 = 0.80). Segmented regression analysis identified a breakpoint at sa-cortisol 9.7 nmol/L and s-cortisol 482 nmol/L, likely corresponding to saturation of cortisol binding globulin (CBG). Healthy subjects on oral estrogens demonstrated a linear agreement between s- and sa-cortisol through all measurements. Seventeen healthy subjects repeated the test, with similar outcome, but reproducibility in terms of intraclass coefficient and correlation was poor.
CONCLUSIONS CONCLUSIONS
Sa-cortisol in cosyntropin-test has high diagnostic accuracy in detecting adrenal insufficiency, and is particularly useful in women on oral estrogens. A sa-cortisol > 12.6 nmol/L assayed with LCMS/MS 60 min after 250µg cosyntropin is normal.

Identifiants

pubmed: 38994578
pii: 7712629
doi: 10.1210/clinem/dgae486
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© The Author(s) 2024. Published by Oxford University Press on behalf of the Endocrine Society.

Auteurs

Kåre Kvam Hellan (K)

Department of Clinical Science, University of Bergen, 5009 Bergen, Norway.

Martin Lyngstad (M)

Department of Clinical Science, University of Bergen, 5009 Bergen, Norway.

Paal Methlie (P)

Department of Clinical Science, University of Bergen, 5009 Bergen, Norway.
Department of Medicine, Haukeland University Hospital, 5021 Bergen, Norway.

Kristian Løvås (K)

Department of Medicine, Haukeland University Hospital, 5021 Bergen, Norway.

Eystein Sverre Husebye (ES)

Department of Clinical Science, University of Bergen, 5009 Bergen, Norway.
Department of Medicine, Haukeland University Hospital, 5021 Bergen, Norway.

Grethe Åstrøm Ueland (GÅ)

Department of Medicine, Haukeland University Hospital, 5021 Bergen, Norway.

Classifications MeSH