High resolution imaging of human development: shedding light on contrast agents.
Contrast agents
High-resolution imaging techniques
Micro-CT
Microvascular tissue imaging
Vascular development
Journal
Neuroradiology
ISSN: 1432-1920
Titre abrégé: Neuroradiology
Pays: Germany
ID NLM: 1302751
Informations de publication
Date de publication:
12 Jul 2024
12 Jul 2024
Historique:
received:
01
03
2024
accepted:
21
06
2024
medline:
12
7
2024
pubmed:
12
7
2024
entrez:
12
7
2024
Statut:
aheadofprint
Résumé
Visualizing (micro)vascular structures remains challenging for researchers and clinicians due to limitations in traditional radiological imaging methods. Exploring the role of vascular development in craniofacial malformations in experimental settings can enhance understanding of these processes, with the effectiveness of high-resolution imaging techniques being crucial for successful research in this field. Micro-CT imaging offers 3D microstructural insights, but requires contrast-enhancing staining agents (CESAs) for visualizing (micro)-vascular tissues, known as contrast-enhanced micro-CT (CECT). As effective contrast agents are crucial for optimal visualization, this review focuses on comparative studies investigating such agents for micro-vascular tissue imaging using micro-CT. Furthermore, we demonstrate the utilization of B-Lugol solution as a promising contrast agent for acquiring high-quality micro-CT images of (micro)vascular structures in human embryonic samples. This scoping review followed Preferred Reporting Items for Systematic Reviews and Meta-analysis Protocols. PubMed database provided relevant articles, screened initially by title and abstract. Inclusion and exclusion criteria defined outcomes of interest. From an initial search, 273 records were identified, narrowed down to 9 articles after applying our criteria. Additionally, two articles were added through citation searching. This, a total of 11 articles were incorporated in this study. This micro-CT contrast agent review underscores the need for tailored choices based on research goals. Both Barium sulfate and Iodine-based agents showing excellent results, providing high resolution (micro) vascular content, especially in ex-vivo specimens. However, careful consideration of protocols and tissue characteristics remains imperative for optimizing the effectiveness of micro-CT imaging for the study of cranio-facial vascular development.
Sections du résumé
BACKGROUND
BACKGROUND
Visualizing (micro)vascular structures remains challenging for researchers and clinicians due to limitations in traditional radiological imaging methods. Exploring the role of vascular development in craniofacial malformations in experimental settings can enhance understanding of these processes, with the effectiveness of high-resolution imaging techniques being crucial for successful research in this field. Micro-CT imaging offers 3D microstructural insights, but requires contrast-enhancing staining agents (CESAs) for visualizing (micro)-vascular tissues, known as contrast-enhanced micro-CT (CECT). As effective contrast agents are crucial for optimal visualization, this review focuses on comparative studies investigating such agents for micro-vascular tissue imaging using micro-CT. Furthermore, we demonstrate the utilization of B-Lugol solution as a promising contrast agent for acquiring high-quality micro-CT images of (micro)vascular structures in human embryonic samples.
METHOD
METHODS
This scoping review followed Preferred Reporting Items for Systematic Reviews and Meta-analysis Protocols. PubMed database provided relevant articles, screened initially by title and abstract. Inclusion and exclusion criteria defined outcomes of interest.
RESULTS
RESULTS
From an initial search, 273 records were identified, narrowed down to 9 articles after applying our criteria. Additionally, two articles were added through citation searching. This, a total of 11 articles were incorporated in this study.
CONCLUSION
CONCLUSIONS
This micro-CT contrast agent review underscores the need for tailored choices based on research goals. Both Barium sulfate and Iodine-based agents showing excellent results, providing high resolution (micro) vascular content, especially in ex-vivo specimens. However, careful consideration of protocols and tissue characteristics remains imperative for optimizing the effectiveness of micro-CT imaging for the study of cranio-facial vascular development.
Identifiants
pubmed: 38995394
doi: 10.1007/s00234-024-03413-z
pii: 10.1007/s00234-024-03413-z
doi:
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2024. The Author(s).
Références
Attia MF, Anton N, Akasov R, Chiper M, Markvicheva E, Vandamme TF (2016) Biodistribution and toxicity of x-ray iodinated contrast agent in nano-emulsions in function of their size. Pharm Res 33(3):603–614. https://doi.org/10.1007/s11095-015-1813-0
doi: 10.1007/s11095-015-1813-0
pubmed: 26511860
Bracco (2017) Iopamidol product monograph. In car-asm.ca. Retrieved June 4, 2023, from https://car-asm.ca/wp-content/uploads/2021/04/ISOVUE-Product-Monograph.pdf
Cole LE, Ross RD, Tilley JM, Vargo-Gogola T, Roeder RK (2015) Gold nanoparticles as contrast agents in x-ray imaging and computed tomography. Nanomedicine (Lond) 10(2):321–341. https://doi.org/10.2217/nnm.14.171
doi: 10.2217/nnm.14.171
pubmed: 25600973
Dawood Y, Hagoort J, Siadari BA, Ruijter JM, Gunst QD, Lobe NHJ, Strijkers GJ, de Bakker BS, van den Hoff MJB (2021) Reducing soft-tissue shrinkage artefacts caused by staining with Lugol’s solution. Sci Rep 11(1):19781. https://doi.org/10.1038/s41598-021-99202-2
doi: 10.1038/s41598-021-99202-2
pubmed: 34611247
pmcid: 8492742
Dawood Y, Strijkers GJ, Limpens J, Oostra RJ, de Bakker BS (2020) Novel imaging techniques to study postmortem human fetal anatomy: a systematic review on microfocus-CT and ultra-high-field MRI. Eur Radiol 30(4):2280–2292. https://doi.org/10.1007/s00330-019-06543-8
doi: 10.1007/s00330-019-06543-8
pubmed: 31834508
Degenhardt K, Wright AC, Horng D, Padmanabhan A, Epstein JA (2010) Rapid 3D phenotyping of cardiovascular development in mouse embryos by micro-CT with iodine staining. Circ Cardiovasc Imaging 3(3):314–322. https://doi.org/10.1161/CIRCIMAGING.109.918482
doi: 10.1161/CIRCIMAGING.109.918482
pubmed: 20190279
pmcid: 3059892
Docter D, Dawood Y, Jacobs K, Hagoort J, Oostra R-J, van den Hoff MJB, Arthurs OJ, de Bakker BS (2023) Microfocus computed tomography for fetal postmortem imaging: an overview. Pediatr Radiol 53(4):632–639. https://doi.org/10.1007/s00247-022-05517-1
doi: 10.1007/s00247-022-05517-1
pubmed: 36169668
Doost A, Arnolda L (2021) Iodine staining outperforms phosphotungstic acid in high-resolution micro-CT scanning of post-natal mice cardiac structures. J Med Imaging (Bellingham, Wash) 8(2):027001. https://doi.org/10.1117/1.JMI.8.2.027001
doi: 10.1117/1.JMI.8.2.027001
du Plessis A, Broeckhoven C, Guelpa A, le Roux SG (2017) Laboratory x-ray micro-computed tomography: a user guideline for biological samples. GigaScience 6(6):1–11. https://doi.org/10.1093/gigascience/gix027
doi: 10.1093/gigascience/gix027
pubmed: 28419369
pmcid: 5449646
Dunmore-Buyze PJ, Tate E, Xiang F, Detombe SA, Nong Z, Pickering JG, Drangova M (2014) Three-dimensional imaging of the mouse heart and vasculature using micro-CT and whole-body perfusion of iodine or phosphotungstic acid. Contrast Media Mol Imaging 9(5):383–390. https://doi.org/10.1002/cmmi.1588
doi: 10.1002/cmmi.1588
pubmed: 24764151
Folkman J (2001) Angiogenesis-dependent diseases. Semin Oncol 28(6):536–542. https://doi.org/10.1016/s0093-7754(01)90021-1
doi: 10.1016/s0093-7754(01)90021-1
pubmed: 11740806
Ghanavati S, Yu LX, Lerch JP, Sled JG (2014) A perfusion procedure for imaging of the mouse cerebral vasculature by X-ray micro-CT. J Neurosci Methods 221:70–77. https://doi.org/10.1016/j.jneumeth.2013.09.002
doi: 10.1016/j.jneumeth.2013.09.002
pubmed: 24056228
Giudice A, Barone S, Belhous K, Morice A, Soupre V, Bennardo F, Boddaert N, Vazquez M-P, Abadie V, Picard A (2018) Pierre Robin sequence: A comprehensive narrative review of the literature over time. J Stomatol Oral Maxillofacial Surg 119(5):419–428. https://doi.org/10.1016/j.jormas.2018.05.002
doi: 10.1016/j.jormas.2018.05.002
Grosso A, Burger MG, Lunger A, Schaefer DJ, Banfi A, di Maggio N (2017) It takes two to tango: Coupling of Angiogenesis and Osteogenesis for bone regeneration. Front Bioeng Biotechnol 5:68. https://doi.org/10.3389/fbioe.2017.00068
doi: 10.3389/fbioe.2017.00068
pubmed: 29164110
pmcid: 5675838
Hallouard F, Anton N, Choquet P, Constantinesco A, Vandamme T (2010) Iodinated blood pool contrast media for preclinical X-ray imaging applications–a review. Biomaterials 31(24):6249–6268. https://doi.org/10.1016/j.biomaterials.2010.04.066
doi: 10.1016/j.biomaterials.2010.04.066
pubmed: 20510444
He W, Ai K, Lu L (2015) Nanoparticulate X-ray CT contrast agents. Sci China Chem 58:753–760
doi: 10.1007/s11426-015-5351-8
Hlushchuk R, Haberthür D, Djonov V (2019) Ex vivo microangioCT: Advances in microvascular imaging. Vascul Pharmacol 112:2–7. https://doi.org/10.1016/j.vph.2018.09.003
doi: 10.1016/j.vph.2018.09.003
pubmed: 30248380
Hlushchuk R, Haberthür D, Soukup P, Barré SF, Khoma O-Z, Schittny J, Haghayegh Jahromi N, Bouchet A, Engelhardt B, Djonov V (2020) Innovative high-resolution microCT imaging of animal brain vasculature. Brain Struct Funct 225(9):2885–2895. https://doi.org/10.1007/s00429-020-02158-8
doi: 10.1007/s00429-020-02158-8
pubmed: 33128675
pmcid: 7674347
Hong S-H, Herman AM, Stephenson JM, Wu T, Bahadur AN, Burns AR, Marrelli SP, Wythe JD (2020) Development of barium-based low viscosity contrast agents for micro CT vascular casting: Application to 3D visualization of the adult mouse cerebrovasculature. J Neurosci Res 98(2):312–324. https://doi.org/10.1002/jnr.24539
doi: 10.1002/jnr.24539
pubmed: 31630455
Iqbal S (2013) A comprehensive study of the anatomical variations of the circle of willis in adult human brains. J Clin Diagnostic Res : JCDR 7(11):2423–2427. https://doi.org/10.7860/JCDR/2013/6580.3563
doi: 10.7860/JCDR/2013/6580.3563
Judex S, Luu YK, Ozcivici E, Adler B, Lublinsky S, Rubin CT (2010) Quantification of adiposity in small rodents using micro-CT. Methods (San Diego, Calif) 50(1):14–19. https://doi.org/10.1016/j.ymeth.2009.05.017
doi: 10.1016/j.ymeth.2009.05.017
pubmed: 19523519
Kingston MJ, Perriman DM, Neeman T, Smith PN, Webb AL (2016) Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study. Contrast Media Mol Imaging 11(4):319–324. https://doi.org/10.1002/cmmi.1695
doi: 10.1002/cmmi.1695
pubmed: 27075920
Lalwani K, Giddabasappa A, Li D, Olson P, Simmons B, Shojaei F, van Arsdale T, Christensen J, Jackson-Fisher A, Wong A, Lappin PB, Eswaraka J (2013) Contrast agents for quantitative microCT of lung tumors in mice. Comp Med 63(6):482–490
pubmed: 24326223
pmcid: 3866987
Le NA, Kuo W, Müller B, Kurtcuoglu V, Spingler B (2020) Crosslinkable polymeric contrast agent for high-resolution X-ray imaging of the vascular system. Chem Commun (Camb) 56(44):5885–5888. https://doi.org/10.1039/c9cc09883f
doi: 10.1039/c9cc09883f
pubmed: 32451523
Li X, Anton N, Zuber G, Vandamme T (2014) Contrast agents for preclinical targeted X-ray imaging. Adv Drug Deliv Rev 76:116–133. https://doi.org/10.1016/j.addr.2014.07.013
doi: 10.1016/j.addr.2014.07.013
pubmed: 25086373
Liu Y, Liu Q, Yang Z, Lin J, Wu X, Huang Z, Liu J, Li R, Huang Z, Wu X, Zhu Q (2019) Comparison of three-dimensional Micro-CT angiography of cervical spinal cord between two contrast agents. Contrast Media Mol Imaging 2019:5215923. https://doi.org/10.1155/2019/5215923
doi: 10.1155/2019/5215923
pubmed: 31110469
pmcid: 6487131
Miltenyi Biotec GmbH (2010) ExiTronTM nano 12000 CT contrast agent for pre-clinical imaging. In Viscover. Retrieved June 4, 2023, from https://static.miltenyibiotec.com/asset/ 150655405641/document_ogf0j788g1095c82uondh0356u/IM0001898.PDF?content-disposition=inline
Nebuloni L, Kuhn GA, Müller R (2013) A comparative analysis of water-soluble and blood-pool contrast agents for in vivo vascular imaging with micro-CT. Acad Radiol 20(10):1247–1255. https://doi.org/10.1016/j.acra.2013.06.003
doi: 10.1016/j.acra.2013.06.003
pubmed: 24029056
Olsson B, Aulie A, Sveen K, Andrew E (1983) Human pharmacokinetics of iohexol. A new nonionic contrast medium. Invest Radiol 18(2):177–182. https://doi.org/10.1097/00004424-198303000-00015
doi: 10.1097/00004424-198303000-00015
pubmed: 6408018
Oumer M, Alemayehu M, Muche A (2021) Association between circle of Willis and ischemic stroke: a systematic review and meta-analysis. BMC Neurosci 22(1):3. https://doi.org/10.1186/s12868-021-00609-4
doi: 10.1186/s12868-021-00609-4
pubmed: 33478402
pmcid: 7818725
Percival CJ, Richtsmeier JT (2013) Angiogenesis and intramembranous osteogenesis. Dev Dyn 242(8):909–922. https://doi.org/10.1002/dvdy.23992
doi: 10.1002/dvdy.23992
pubmed: 23737393
pmcid: 3803110
Rajabi M, Mousa SA (2017) The role of angiogenesis in cancer treatment. Biomedicines 5(2). https://doi.org/10.3390/biomedicines5020034
Roche B, David V, Vanden-Bossche A, Peyrin F, Malaval L, Vico L, Lafage-Proust M-H (2012) Structure and quantification of microvascularisation within mouse long bones: what and how should we measure? Bone 50(1):390–399. https://doi.org/10.1016/j.bone.2011.09.051
doi: 10.1016/j.bone.2011.09.051
pubmed: 22019874
Sanz J, Fayad ZA (2008) Imaging of atherosclerotic cardiovascular disease. Nature 451(7181):953–957. https://doi.org/10.1038/nature06803
doi: 10.1038/nature06803
pubmed: 18288186
Schaad L, Hlushchuk R, Barré S, Gianni-Barrera R, Haberthür D, Banfi A, Djonov V (2017) Correlative imaging of the murine hind limb vasculature and muscle tissue by MicroCT and light microscopy. Sci Rep 7:41842. https://doi.org/10.1038/srep41842
doi: 10.1038/srep41842
pubmed: 28169309
pmcid: 5294414
Schambach SJ, Bag S, Groden C, Schilling L, Brockmann MA (2010) Vascular imaging in small rodents using micro-CT. Methods (San Diego, Calif) 50(1):26–35. https://doi.org/10.1016/j.ymeth.2009.09.003
doi: 10.1016/j.ymeth.2009.09.003
pubmed: 19772922
Singh J, Daftary A (2008) Iodinated contrast media and their adverse reactions. J Nuclear Med Technol 36(2):69–74. https://doi.org/10.2967/jnmt.107.047621 . quiz 76–77
doi: 10.2967/jnmt.107.047621
Swain MV, Xue J (2009) State of the art of Micro-CT applications in dental research. Int J Oral Sci 1(4):177–188. https://doi.org/10.4248/IJOS09031
doi: 10.4248/IJOS09031
pubmed: 20690421
pmcid: 3470105
ter Voert CEM, Kour RYN, van Teeffelen BCJ, Ansari N, Stok KS (2020) Contrast-enhanced micro-computed tomography of articular cartilage morphology with ioversol and iomeprol. J Anat 237(6):1062–1071. https://doi.org/10.1111/joa.13271
doi: 10.1111/joa.13271
pubmed: 32683740
pmcid: 7704241
Tricco AC, Lillie E, Zarin W, O’Brien KK, Colquhoun H, Levac D, Moher D, Peters MDJ, Horsley T, Weeks L, Hempel S, Akl EA, Chang C, McGowan J, Stewart L, Hartling L, Aldcroft A, Wilson MG, Garritty C, … Straus SE (2018) PRISMA Extension for Scoping Reviews (PRISMA-ScR): Checklist and Explanation. Annal Internal Med 169(7):467–473. https://doi.org/10.7326/M18-0850
van Seeters T, Biessels GJ, Kappelle LJ, van der Schaaf IC, Dankbaar JW, Horsch AD, Niesten JM, Luitse MJ, Majoie CB, Vos JA, Schonewille WJ, van Walderveen MA, Wermer MJ, Duijm LE, Keizer K, Bot JC, Visser MC, van der Lugt A, Dippel DW, … Dutch acute stroke study (DUST) investigators. (2015). The Prognostic Value of CT Angiography and CT Perfusion in Acute Ischemic Stroke. Cerebrovascular Dis (Basel, Switzerland) 40(5–6):258–269. https://doi.org/10.1159/000441088
Xu H-M, Wang Y-L, Jin H-M, Xu D-L, Xuan J, Chen J-X, Goswami A, Tao Z-S, Zhou F, Zhang X-L, Wang X-Y (2017) A novel micro-CT-based method to monitor the morphology of blood vessels in the rabbit endplate. Euro Spine J : Official Publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society 26(1):221–227. https://doi.org/10.1007/s00586-016-4849-x
doi: 10.1007/s00586-016-4849-x