Frequency and management of rod fractures following minimally invasive bipolar fusionless surgery in neuromuscular scoliosis patients.
Fusionless minimal invasive surgery
Neuromuscular scoliosis
Pediatric
Rod breakage
Spine surgery
Journal
Archives de pediatrie : organe officiel de la Societe francaise de pediatrie
ISSN: 1769-664X
Titre abrégé: Arch Pediatr
Pays: France
ID NLM: 9421356
Informations de publication
Date de publication:
13 Jul 2024
13 Jul 2024
Historique:
received:
26
10
2023
accepted:
16
04
2024
medline:
14
7
2024
pubmed:
14
7
2024
entrez:
13
7
2024
Statut:
aheadofprint
Résumé
Neuromuscular scoliosis (NMS) is associated with an abnormal muscle tone. Traditional conservative treatments, with the historical practice of early posterior fusion, have proven ineffective. Recently, growth-sparing techniques have gained traction owing to their ability to maximize trunk height. However, these techniques have a substantial risk of complications, particularly rod breakage, with reported incidence rates ranging from 15 % to 42 %. The objective of this study was to conduct a descriptive analysis of NMS patients who experienced rod breakage following the minimally invasive fusionless surgery (MIFS) technique. This was a single-center, retrospective study that included all NMS patients who underwent surgery between January 2015 and January 2021 and subsequently presented with rod breakage after MIFS. The MIFS technique is based on proximal fixation with double hook claws made of pedicular and -sus laminar hooks and pelvic fixation with iliosacral screws. The mean follow-up was 5.2 ± 2.2 years. The mean dominant etiology of NMS was cerebral palsy (67 %). Of the 217 patients who underwent surgery, 15 (6.9 %) developed rod breakage. Rod breakage occurred 2.7 ± 1.3 years after the initial surgery. Four cases of rod fracture recurrence were reported in ambulatory patients with dystonia or hyperactivity. Compared with other fusionless techniques, the minimally invasive bipolar technique appears promising for patients with NMS, with a lower rate of rod breakage. We recommend the use of a four-rod construct for ambulatory patients or for those with dystonia or hyperactivity.
Identifiants
pubmed: 39003159
pii: S0929-693X(24)00087-3
doi: 10.1016/j.arcped.2024.04.004
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 French Society of Pediatrics. Published by Elsevier Masson SAS. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest All Authors report no conflict of interest.