Initial Experience with the Derivo 2Heal Flow Diverter under Standard or Reduced-Dose Single Antiplatelet Therapy.
Journal
AJNR. American journal of neuroradiology
ISSN: 1936-959X
Titre abrégé: AJNR Am J Neuroradiol
Pays: United States
ID NLM: 8003708
Informations de publication
Date de publication:
18 Jul 2024
18 Jul 2024
Historique:
received:
20
11
2023
accepted:
09
03
2024
medline:
19
7
2024
pubmed:
19
7
2024
entrez:
18
7
2024
Statut:
aheadofprint
Résumé
Flow diverters with surface modifications or coatings have been recently introduced to clinical practice with the expectation that they can reduce the rate of thromboembolic complications and residual aneurysms. The purpose of this study is to evaluate the utility of the Derivo 2Heal (D2H) device, a new fibrin and heparin-coated flow diverter. Patients treated by a single operator by using the D2H were retrospectively evaluated for demographic data, aneurysm characteristics, procedural variables, and follow-up data. All patients were treated by using a single D2H, monitored by platelet function testing and kept under single antiplatelet therapy with regular or half-dose clopidogrel or prasugrel after the procedure. Twenty patients with 26 aneurysms were treated. Three presented acutely with subarachnoid hemorrhage. Adjunctive devices were used in 6 patients. There were no technical failures and 2 periprocedural self-limited nonthrombotic minor adverse events. During follow-up, 1 of the acutely ruptured aneurysms reruptured, and 1 patient had a visual TIA. All patients were doing well clinically (19 with mRS of 0 and 1 with 1) at the last follow-up after discharge. The rates of total occlusion on very early angiographic (MRA/CTA or DSA, mean: 2.4 months), DSA (mean: 5.8 months), and midterm angiographic (mean: 14.5 months) follow-up for all versus uncoiled aneurysms were 68% versus 70%, 77.8% versus 90.0%, and 91.7% versus 90.1%, respectively. The absence of permanent neurologic deficits in the periprocedural period and favorable occlusion rates in this preliminary study suggest that the novel coating comprising fibrin and heparin may have the potential to increase the safety and efficacy of flow diversion and needs to be further studied by comparing the D2H device with its bare counterpart and other coated or surface-modified flow diverters.
Sections du résumé
BACKGROUND AND PURPOSE
OBJECTIVE
Flow diverters with surface modifications or coatings have been recently introduced to clinical practice with the expectation that they can reduce the rate of thromboembolic complications and residual aneurysms. The purpose of this study is to evaluate the utility of the Derivo 2Heal (D2H) device, a new fibrin and heparin-coated flow diverter.
MATERIALS AND METHODS
METHODS
Patients treated by a single operator by using the D2H were retrospectively evaluated for demographic data, aneurysm characteristics, procedural variables, and follow-up data. All patients were treated by using a single D2H, monitored by platelet function testing and kept under single antiplatelet therapy with regular or half-dose clopidogrel or prasugrel after the procedure.
RESULTS
RESULTS
Twenty patients with 26 aneurysms were treated. Three presented acutely with subarachnoid hemorrhage. Adjunctive devices were used in 6 patients. There were no technical failures and 2 periprocedural self-limited nonthrombotic minor adverse events. During follow-up, 1 of the acutely ruptured aneurysms reruptured, and 1 patient had a visual TIA. All patients were doing well clinically (19 with mRS of 0 and 1 with 1) at the last follow-up after discharge. The rates of total occlusion on very early angiographic (MRA/CTA or DSA, mean: 2.4 months), DSA (mean: 5.8 months), and midterm angiographic (mean: 14.5 months) follow-up for all versus uncoiled aneurysms were 68% versus 70%, 77.8% versus 90.0%, and 91.7% versus 90.1%, respectively.
CONCLUSIONS
CONCLUSIONS
The absence of permanent neurologic deficits in the periprocedural period and favorable occlusion rates in this preliminary study suggest that the novel coating comprising fibrin and heparin may have the potential to increase the safety and efficacy of flow diversion and needs to be further studied by comparing the D2H device with its bare counterpart and other coated or surface-modified flow diverters.
Identifiants
pubmed: 39025640
pii: ajnr.A8292
doi: 10.3174/ajnr.A8292
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2024 by American Journal of Neuroradiology.