Intraoperative somatosensory evoked potential (SEP) monitoring: an updated position statement by the American Society of Neurophysiological Monitoring.
IONM
Intraoperative neuromonitoring
Neurophysiological monitoring
SEP
SSEP
Somatosensory evoked potentials
Journal
Journal of clinical monitoring and computing
ISSN: 1573-2614
Titre abrégé: J Clin Monit Comput
Pays: Netherlands
ID NLM: 9806357
Informations de publication
Date de publication:
27 Jul 2024
27 Jul 2024
Historique:
received:
05
07
2024
accepted:
16
07
2024
medline:
28
7
2024
pubmed:
28
7
2024
entrez:
27
7
2024
Statut:
aheadofprint
Résumé
Somatosensory evoked potentials (SEPs) are used to assess the functional status of somatosensory pathways during surgical procedures and can help protect patients' neurological integrity intraoperatively. This is a position statement on intraoperative SEP monitoring from the American Society of Neurophysiological Monitoring (ASNM) and updates prior ASNM position statements on SEPs from the years 2005 and 2010. This position statement is endorsed by ASNM and serves as an educational service to the neurophysiological community on the recommended use of SEPs as a neurophysiological monitoring tool. It presents the rationale for SEP utilization and its clinical applications. It also covers the relevant anatomy, technical methodology for setup and signal acquisition, signal interpretation, anesthesia and physiological considerations, and documentation and credentialing requirements to optimize SEP monitoring to aid in protecting the nervous system during surgery.
Identifiants
pubmed: 39068294
doi: 10.1007/s10877-024-01201-x
pii: 10.1007/s10877-024-01201-x
doi:
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2024. The Author(s).
Références
Larson SJ, Sances A Jr. Evoked potentials in man: neurosurgical applications. Am J Surg. 1966;111(6):857–61. https://doi.org/10.1016/0002-9610(66)90189-9 .
doi: 10.1016/0002-9610(66)90189-9
pubmed: 5326593
McCallum JE, Bennett MH. Electrophysiologic monitoring of spinal cord function during intraspinal surgery. Surg Forum. 1975;26:469–71.
pubmed: 1216195
Nash CL, Lorig RA, Schatzinger LA, Brown RH. Spinal cord monitoring during operative treatment of the spine. Clin Orthop Relat Res. 1977;126:100–5.
Tamaki T, Kubota S. History of the development of intraoperative spinal cord monitoring. Eur Spine J. 2007;16(Suppl 2):S140-6. https://doi.org/10.1007/s00586-007-0416-9 .
doi: 10.1007/s00586-007-0416-9
pubmed: 17668250
Larson SJ, Sances AJ Jr, Christenson PC. Evoked somatosensory potentials in man. Arch Neurol. 1966;15(1):88–93. https://doi.org/10.1001/archneur.1966.00470130092010 .
doi: 10.1001/archneur.1966.00470130092010
pubmed: 5937499
Engler GL, Spielholz NJ, Bernhard WN, Danziger F, Merkin H, Wolff T. Somatosensory evoked potentials during Harrington Instrumentation for scoliosis. J Bone Joint Surg Am. 1978;60(4):528–32.
pubmed: 670276
doi: 10.2106/00004623-197860040-00016
Cunningham JN, Laschinger JC, Merkin HA, Nathan IM, Colvin S, Ransohoff J, et al. Measurement of spinal cord ischemia during operations upon the thoracic aorta: Initial clinical experience. Ann Surg. 1982;196(3):285–96. https://doi.org/10.1097/00000658-198209000-00007 .
doi: 10.1097/00000658-198209000-00007
pubmed: 7114935
pmcid: 1352600
Cunningham JN, Laschinger JC, Spencer FC. Monitoring of somatosensory evoked potentials during surgical procedures on the thoracoabdominal aorta. IV. Clinical observations and results. J Thorac Cardiovasc Surg. 1987;94(2):275–85.
pubmed: 3613628
doi: 10.1016/S0022-5223(19)36294-4
Cushman L, Brinkman SD, Ganji S, Jacobs LA. Neurophysiological impairment after carotid endarterectomy correlates with intraoperative ischemia. Cortex. 1984;20(3):403–12. https://doi.org/10.1016/S0010-9452(84)80008-8 .
doi: 10.1016/S0010-9452(84)80008-8
pubmed: 6488816
Lopez JR, Chang SD, Steinberg GK. The use of electrophysiological monitoring in the intraoperative management of intracranial aneurysms. J Neurol Neurosurg Psychiatry. 1999;66(2):189–96. https://doi.org/10.1136/jnnp.66.2.189 .
doi: 10.1136/jnnp.66.2.189
pubmed: 10071098
pmcid: 1736209
Toleikis JR, Carlvin AO, Shapiro DE, Schafer MF. The use of dermatomal evoked responses during surgical procedures that use intrapedicular fixation of the lumbosacral spine. Spine (Phila Pa). 1993;18(16):2401–7. https://doi.org/10.1097/00007632-199312000-00006 .
doi: 10.1097/00007632-199312000-00006
AEEGS. American Electroencephalographic Society guidelines for intraoperative monitoring of sensory evoked potentials. J Clin Neurophysiol. 1987;4(4):397–416.
doi: 10.1097/00004691-198710000-00005
AEEGS. Guideline eleven: guidelines for intraoperative monitoring of sensory evoked potentials. Clin Neurophysiol. 1994;11(1):77–87.
doi: 10.1097/00004691-199401000-00012
ASET. American Society of Electroneurodiagnostic Technologists, Inc, Guidelines on intraoperative electroencephalography for technologists. Am J Electroneurodiagn Technol. 1998;38(3):204–25. https://doi.org/10.1080/1086508X.1998.11079229 .
doi: 10.1080/1086508X.1998.11079229
OSET. International Organization of Societies for Electrophysiological Technology (OSET). Guidelines for performing EEG and evoked potential monitoring during surgery. Am J END Technol. 1999;39(4):257–77. https://doi.org/10.1080/1086508X.1999.11079270 .
doi: 10.1080/1086508X.1999.11079270
Nuwer MR, Daube J, Fischer C, Schramm J, Yingling CD. Neuromonitoring during surgery. Report of an IFCN committee. Electroencephalogr Clin Neurophysiol. 1993;87(5):263–76. https://doi.org/10.1016/0013-4694(93)90179-y .
doi: 10.1016/0013-4694(93)90179-y
pubmed: 7693437
American Clinical Neurophysiology Society. Guideline 9D: guidelines on short-latency somatosensory evoked potentials. J Clin Neurophysiol. 2006;23(2):168–79. https://doi.org/10.1097/00004691-200604000-00013 .
doi: 10.1097/00004691-200604000-00013
American Clinical Neurophysiology Society. www.acns.org . 2009. Available from: https://www.acns.org/pdf/guidelines/Guideline-11B.pdf . Accessed 11 Feb 2024.
Nuwer MR, Emerson RG, Galloway G, Legatt AD, Lopez J, Minahan R, et al. Evidence-based guideline update: intraoperative spinal monitoring with somatosensory and transcranial electrical motor evoked potentials: report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology and the ACNS. Neurology. 2012;78(8):585–9. https://doi.org/10.1212/WNL.0b013e318247fa0e .
doi: 10.1212/WNL.0b013e318247fa0e
pubmed: 22351796
Toleikis JR. Intraoperative monitoring using somatosensory evoked potentials. A position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2005;19(3):241–58. https://doi.org/10.1007/s10877-005-4397-0 .
doi: 10.1007/s10877-005-4397-0
pubmed: 16244848
Toleikis JR. Intraoperative monitoring using somatosensory evoked potentials. A position statement by the American Society of Neurophysiological Monitoring. 2010. https://www.asnm.org/assets/docs/sep.pdf . Accessed 5 July 2022
MacDonald DB, Dong C, Quatrale R, Sala F, Skinner S, Soto F, et al. Recommendations of the International Society of Intraoperative Neurophysiology for intraoperative somatosensory evoked potentials. Clin Neurophysiol. 2019;130(1):161–79. https://doi.org/10.1016/j.clinph.2018.10.008 .
doi: 10.1016/j.clinph.2018.10.008
pubmed: 30470625
Mahla ME, Long DM, McKennett J, Green C, McPherson RW. Detection of brachial plexus dysfunction by somatosensory evoked potential monitoring—a report of two cases. Anesthesiology. 1984;60(3):248–52. https://doi.org/10.1097/00000542-198403000-00019 .
doi: 10.1097/00000542-198403000-00019
pubmed: 6696265
Nercessian OA, Gonzalez EG, Stinchfield FE. The use of somatosensory evoked potentials during revision or reoperation for total hip arthroplasty. Clin Orthop Relat Res. 1989;243:138–42.
doi: 10.1097/00003086-198906000-00020
Pitman MI, Nainzadeh N, Ergas E, Springer S. The use of somatosensory evoked potentials for detection of neuropraxia during shoulder arthroscopy. Arthroscopy. 1988;4(4):250–5. https://doi.org/10.1016/s0749-8063(88)80039-2 .
doi: 10.1016/s0749-8063(88)80039-2
pubmed: 3233113
Porter SS, Black DJ, Reckling FW, Mason J. Intraoperative cortical somatosensory evoked potentials for detection of sciatic neuropathy during total hip arthroplasty. J Clin Anesth. 1989;1(3):170–6. https://doi.org/10.1016/0952-8180(89)90037-8 .
doi: 10.1016/0952-8180(89)90037-8
pubmed: 2627384
Prielipp RC, Morell RC, Walker FO, Santos CC, Bennett J, Butterworth J. Ulnar nerve pressure: influence of arm position and relationship to somatosensory evoked potentials. Anesthesiology. 1999;91(2):345–54. https://doi.org/10.1097/00000542-199908000-00006 .
doi: 10.1097/00000542-199908000-00006
pubmed: 10443595
Gu B, Xie F, Jiang H, Shen G, Li Q. Repair of electrically injured median nerve with the aid of somatosensory evoked potential. Microsurgery. 2009;29(6):449–55. https://doi.org/10.1002/micr.20631 .
doi: 10.1002/micr.20631
pubmed: 19308956
Salengros JC, Pandin P, Schuind F, Vandersteene A. Intraoperative somatosensory evoked potentials to facilitate peripheral nerve release. Can J Anaesth. 2006;53(1):40–5. https://doi.org/10.1007/BF03021526 .
doi: 10.1007/BF03021526
pubmed: 16371608
Kothbauer KF, Deletis V. Intraoperative neurophysiology of the conus medullaris and cauda equina. Childs Nerv Syst. 2010;26(2):247–53. https://doi.org/10.1007/s00381-009-1020-6 .
doi: 10.1007/s00381-009-1020-6
pubmed: 19904544
Jones SJ, Edgar MA, Ransford AO, Thomas NP. A system for electrophysiological monitoring of the spinal cord during operations for scoliosis. J Bone Jt Surg Br. 1983;65(2):134–9. https://doi.org/10.1302/0301-620X.65B2.6826615 .
doi: 10.1302/0301-620X.65B2.6826615
Macon JB, Poletti CE. Conducted somatosensory and evoked potentials during spinal surgery. Part I: control conduction velocity measurements. J Neurosurg. 1982;57(3):349–53. https://doi.org/10.3171/jns.1982.57.3.0349 .
doi: 10.3171/jns.1982.57.3.0349
pubmed: 7097330
Nuwer MR, Dawson E. Intraoperative evoked potential monitoring of the spinal cord: enhanced stability of cortical recordings. Electroenceph Clin Neurophysiol. 1984;59(4):318–27. https://doi.org/10.1016/0168-5597(84)90049-2 .
doi: 10.1016/0168-5597(84)90049-2
pubmed: 6203721
Hargadine JR, Snyder E. Brain stem somatosensory evoked potentials: application in the operating room and intensive care unit. Bull Los Angeles Neurol Soc. 1982;47:62–75.
pubmed: 7183367
Friedman WA, Chadwick GM, Frank MA, Verhoeven JS, Mahla M, Day AL. Monitoring of somatosensory evoked potentials during surgery for middle cerebral artery aneurysms. Neurosurgery. 1991;29(1):83–8. https://doi.org/10.1097/00006123-199107000-00014 .
doi: 10.1097/00006123-199107000-00014
pubmed: 1870692
Lam AM, Manninen PH, Ferguson GG, Nantau W. Monitoring electrophysiologic function during carotid endarterectomy: a comparison of somatosensory evoked potentials and conventional electroencephalogram. Anesthesiology. 1991;75(1):15–21. https://doi.org/10.1097/00000542-199107000-00004 .
doi: 10.1097/00000542-199107000-00004
pubmed: 2064043
Simon MV, Chiappa KH, Borges LF. Phase reversal of somatosensory evoked potentials triggered by gracilis tract stimulation: case report of a new technique for neurophysiologic dorsal column mapping. Neurosurgery. 2012;70(3):E783–8. https://doi.org/10.1227/NEU.0b013e31822e0a76 .
doi: 10.1227/NEU.0b013e31822e0a76
pubmed: 21778916
Nair D, Kumaraswamy VM, Braver D, Kilbride RD, Borges LF, Simon MV. Dorsal column mapping via phase reversal method: the refined technique and clinical applications. Neurosurgery. 2014;74(4):437–46. https://doi.org/10.1227/NEU.0000000000000287 .
doi: 10.1227/NEU.0000000000000287
pubmed: 24448182
Deletis V, Bueno De Camargo A. Interventional neurophysiological mapping during spinal cord procedures. Stereotact Funct Neurosurg. 2001;77(1):25–8. https://doi.org/10.1159/000064585 .
doi: 10.1159/000064585
pubmed: 12378052
Yanni DS, Ulkatan S, Deletis V, Barrenechea IJ, Sen C, Perin NI. Utility of neurophysiological monitoring using dorsal column mapping in intramedullary spinal cord surgery. J Neurosurg Spine. 2010;12(6):623–8. https://doi.org/10.3171/2010.1.SPINE09112 .
doi: 10.3171/2010.1.SPINE09112
pubmed: 20515347
Scibilia A, Terranova C, Rizzo V, Raffa G, Morelli A, Esposito F, et al. Intraoperative neurophysiological mapping and monitoring in spinal tumor surgery: sirens or indispensable tools? Neurosurg Focus. 2016;41(2):E18. https://doi.org/10.3171/2016.5.FOCUS16141 .
doi: 10.3171/2016.5.FOCUS16141
pubmed: 27476842
Balzer JR, Tomycz ND, Crammond DJ, Habeych M, Thriumala PD, Urgo L, et al. Localization of cervical and cervicomedullary stimulation leads for pain treatment using median nerve somatosensory evoked potential collision testing. J Neurosurg. 2011;114(1):200–5. https://doi.org/10.3171/2010.5.JNS091640 .
doi: 10.3171/2010.5.JNS091640
pubmed: 20509731
Shils JL, Arle JE. Neuromonitoring for spinal cord stimulation lead placement under general anesthesia. J Clin Neurol. 2018;14(4):444–53. https://doi.org/10.3988/jcn.2018.14.4.444 .
doi: 10.3988/jcn.2018.14.4.444
pubmed: 30198227
pmcid: 6172495
Celesia GG. Somatosensory evoked potentials recorded directly from human thalamus and Sm I cortical area. Arch Neurol. 1979;36(7):399–405. https://doi.org/10.1001/archneur.1979.00500430029003 .
doi: 10.1001/archneur.1979.00500430029003
pubmed: 454244
Kelly DL Jr, Goldring S, O’Leary JL. Averaged evoked somatosensory responses from exposed cortex of man. Arch Neurol. 1965;13:1–9. https://doi.org/10.1001/archneur.1965.00470010005001 .
doi: 10.1001/archneur.1965.00470010005001
pubmed: 14314270
Lueders H, Lesser RP, Hahn J, Dinner DS, Klem G. Cortical somatosensory evoked potentials in response to hand stimulation. J Neurosurg. 1983;58(6):885–94. https://doi.org/10.3171/jns.1983.58.6.0885 .
doi: 10.3171/jns.1983.58.6.0885
pubmed: 6854381
Allison T, McCarthy G, Wood CC, Darcey TM, Spencer DD, Williamson PD. Human cortical potentials evoked by stimulation of the median nerve. I. Cytoarchitectonic areas generating short-latency activity. J Neurophysiol. 1989;62(3):694–710. https://doi.org/10.1152/jn.1989.62.3.694 .
doi: 10.1152/jn.1989.62.3.694
pubmed: 2769354
Romstöck J, Fahlbusch R, Ganslandt O, Nimsky C, Strauss C. Localisation of the sensorimotor cortex during surgery for brain tumors: feasibility and waveform patterns of somatosensory evoked potentials. J Neurol Neurosurg Psychiatry. 2002;72(2):221–9. https://doi.org/10.1136/jnnp.72.2.221 .
doi: 10.1136/jnnp.72.2.221
pubmed: 11796773
pmcid: 1737735
Wood CC, Spencer DD, Allison T, McCarthy G, Williamson PD, Goff WR. Localization of human sensorimotor cortex during surgery by cortical surface recording of somatosensory evoked potentials. J Neurosurg. 1988;68(1):99–111. https://doi.org/10.3171/jns.1988.68.1.0099 .
doi: 10.3171/jns.1988.68.1.0099
pubmed: 3275756
MacDonald DB. Monitoring somatosensory evoked potentials. In: Deletis V, Shils JL, Sala F, Seidel K, editors. Neurophysiology in neurosurgery: a modern approach. 2nd ed. New York: Academic Press; 2020. p. 35–51.
doi: 10.1016/B978-0-12-815000-9.00003-4
Tomé-Bermejo F, Garrido E, Glasby M, Thinn S. Rare true-positive isolated SSEP loss with preservation of MEPs response during scoliosis correction. Spine (Phila Pa 1976). 2014;39(1):E60–3. https://doi.org/10.1097/BRS.0000000000000076 .
doi: 10.1097/BRS.0000000000000076
pubmed: 24153165
Gardner EP. Receptors of the somatosensory system. In: Kandel ER, Koester JD, Mack SH, Sieglebaum SA, editors. Principles of neural science. 6th ed. New York: McGraw-Hill; 2021. p. 408–34.
Gardner EP. Touch. In: Kandel ER, Koester JD, Mack JD, Siegelbaum SA, editors. Principles of neural science. 6th ed. New York: McGraw-Hill; 2021. p. 435–69.
Nielsen JB, Jessell TM. Sensorimotor integration in the spinal cord. In: Kandel ER, Koester JD, Mack SH, Siegelbaum SA, editors. Principles of neural science. 6th ed. New York: McGraw-Hill; 2021. p. 761–82.
Standring S. Spinal Cord. In: Standring S, editor. Gray’s anatomy—the anatomical basis of clinical practice. 42nd ed. London: Elsevier; 2020. p. 425–41.
Haines DE. Synopsis of functional components, tracts, pathways, and systems: examples in anatomical and clinical orientation. In: Neuroanatomy atlas in clinical context. structures, sections, systems and syndromes. 10th ed. Baltimore: Walters Kluwer; 2019. p. 175–263.
Splittgerber R. Spinal cord and ascending, descending and intersegmental tracts. In: Splittgerber R, editor. Snell’s clinical neuroanatomy. 8th ed. Philadelphia: Wolters Kluwer; 2019. p. 131–84.
Adams AH, Samuels MA, Klein JP, Prasad S. Disorders of non-painful somatic sensation. In: Adams AH, Samuels MA, Klein JP, editors. Prasad S. Adams and Victor’s principles of neurology. 11th ed. New York: McGraw-Hill; 2019.
Cohen AR, Young W, Ransohoff J. Intraspinal localization of the somatosensory evoked potential. Neurosurgery. 1981;9(2):157–62. https://doi.org/10.1227/00006123-198108000-00008 .
doi: 10.1227/00006123-198108000-00008
pubmed: 7266814
Cusick JF, Myklebust JF, Larson SJ, Sances AJ. Spinal evoked potentials in the primate: neural substrate. J Neurosurg. 1978;49(4):551–7. https://doi.org/10.3171/jns.1978.49.4.0551 .
doi: 10.3171/jns.1978.49.4.0551
pubmed: 690684
Macon JB, Poletti CE, Sweet WH, Ojemann RG, Zervas N. Conducted somatosensory evoked potentials during spinal surgery. Part 2: clinical applications. J Neurosurg. 1982;57(3):354–9. https://doi.org/10.3171/jns.1982.57.3.0354 .
doi: 10.3171/jns.1982.57.3.0354
pubmed: 7097331
Jones SJ, Edgar MA, Ransford AO. Sensory nerve conduction in the human spinal cord: epidural recordings made during spinal cord surgery. J Neurol Neurosurg Psychiatry. 1982;45(5):446–51. https://doi.org/10.1136/jnnp.45.5.446 .
doi: 10.1136/jnnp.45.5.446
pubmed: 6283032
pmcid: 1083125
York DH. Somatosensory evoked potentials in man: differentiation of spinal pathways responsible for conduction from forelimbs vs hindlimb. Prog Neurobiol. 1985;25(1):1–25. https://doi.org/10.1016/0301-0082(85)90021-8 .
doi: 10.1016/0301-0082(85)90021-8
pubmed: 3909220
Powers SK, Bolger CA, Edwards MS. Spinal cord pathways mediating somatosensory evoked potentials. J Neurosurg. 1982;57(4):472–82. https://doi.org/10.3171/jns.1982.57.4.0472 .
doi: 10.3171/jns.1982.57.4.0472
pubmed: 7108596
Simpson RKJ, Blackburn JG, Martin HFI, Katz S. Peripheral nerve fibers and spinal cord pathway contribution to the somatosensory evoked potentials. Exp Neurol. 1981;73(3):700–15. https://doi.org/10.1016/0014-4886(81)90206-5 .
doi: 10.1016/0014-4886(81)90206-5
pubmed: 6266861
Brau SA, Spoonamore MJ, Snyder L, Gilbert C, Rhonda G, Williams LA, et al. Nerve monitoring changes related to iliac artery compression during anterior lumbar spine surgery. Spine J. 2003;3(5):351–5. https://doi.org/10.1016/s1529-9430(03)00067-6 .
doi: 10.1016/s1529-9430(03)00067-6
pubmed: 14588945
Jones SC, Fernau R, Woeltjen BL. Use of somatosensory evoked potentials to detect peripheral ischemia and potential injury resulting from positioning of the surgical patient: case reports and discussion. Spine J. 2004;4(3):360–2. https://doi.org/10.1016/j.spinee.2003.08.023 .
doi: 10.1016/j.spinee.2003.08.023
pubmed: 15125862
Yaylali I, Ju H, Yoo J, Ching A, Hart R. Intraoperative neurophysiological monitoring in anterior lumbar interbody fusion surgery. J Clin Neurophysiol. 2014;31(4):352–5. https://doi.org/10.1097/WNP.0000000000000073 .
doi: 10.1097/WNP.0000000000000073
pubmed: 25083847
Vossler DG, Stonecipher T, Millen MD. Femoral artery ischemia during spinal scoliosis surgery detected by posterior tibial nerve somatosensory-evoked potential monitoring. Spine (Phila Pa 1976). 2000;25(11):1457–9. https://doi.org/10.1097/00007632-200006010-00021 .
doi: 10.1097/00007632-200006010-00021
pubmed: 10828931
Kamel I, Zhao H, Koch SA, Brister N, Barnette RE. The use of somatosensory evoked potentials to determine the relationship between intraoperative arterial blood pressure and intraoperative upper extremity position-related neurapraxia in the prone surrender position during spine surgery: a retrospective. Anesth Analg. 2016;122(5):1423–33. https://doi.org/10.1213/ANE.0000000000001121 .
doi: 10.1213/ANE.0000000000001121
pubmed: 26720618
Silverstein JW, Matthews E, Mermelstein LE, DeWal H. Causal factors for position-related SSEP changes in spinal surgery. Eur Spine J. 2016;25(10):3208–13. https://doi.org/10.1007/s00586-016-4618-x .
doi: 10.1007/s00586-016-4618-x
pubmed: 27209584
Daube JR. Anatomy. In: Handbook of clinical neurophysiology. Amsterdam: Elsevier; 2008. p. 44–76.
Djindjian R, Hurth M, Houdart R. Arterial supply of the spinal cord. In: Djindjin R, editor. Angiograph of the spinal cord. Baltimore: University Park Press; 1970. p. 3–13.
Sloan TB, Jameson LC, Clavijo CF. Electrophysiological monitoring during thoracic aortic aneurysm surgery. In: Koht A, Sloan TB, Toleikis JR, editors. Monitoring the nervous system for anesthesiologists and other health care professionals. 2nd ed. Cham: Springer; 2017. p. 601–16.
doi: 10.1007/978-3-319-46542-5_40
Zornow MH, Grafe MR, Tybor C, Swenson MR. Preservation of evoked potentials in a case of anterior spinal artery syndrome. Electroencephalogr Clin Neurophysiol. 1990;77(2):137–9. https://doi.org/10.1016/0168-5597(90)90028-c .
doi: 10.1016/0168-5597(90)90028-c
pubmed: 1690114
Zouridakis G, Papanicolaou AC. A concise guide to intraoperative monitoring. Boca Raton: CRC Press; 2001.
Stevenson M, Baylor K, Netherton BL, Stecker MM. Electrical stimulation and electrode properties. Part 2: pure metal electrodes. Am J Electroneurodiagn Technol. 2010;50(4):263–96.
doi: 10.1080/1086508X.2010.11079783
Quraishi NA, Lewis SJ, Kelleher MO, Sarjeant R, Rampersaud YR, Fehlings MF. Intraoperative multimodality monitoring in adult spinal deformity: analysis of a prospective series of one hundred two cases with independent evaluation. Spine (Phila Pa 1976). 2009;34(14):1504–12. https://doi.org/10.1097/BRS.0b013e3181a87b66 .
doi: 10.1097/BRS.0b013e3181a87b66
pubmed: 19483667
Jahangiri FR, Sherman JH, Sheehan J, Shaffrey M, Dumont AS, Vengrow M, et al. Limiting the current density during localization of the primary motor cortex by using a tangential-radial cortical somatosensory evoked potentials model, direct electrical cortical stimulation, and electrocorticography. Neurosurgery. 2011;69(4):893–8. https://doi.org/10.1227/NEU.0b013e3182230ac3 .
doi: 10.1227/NEU.0b013e3182230ac3
pubmed: 21562433
Mills WJ, Chapman JR, Robinson LR, Slimp JC. Somatosensory evoked potential monitoring during closed humeral nailing: a preliminary report. J Orthop Trauma. 2000;14(3):167–70. https://doi.org/10.1097/00005131-200003000-00003 .
doi: 10.1097/00005131-200003000-00003
pubmed: 10791666
Jahangiri FR, Blaylock J, Qadir N, Ramsey JA. Multimodality intraoperative neurophysiological monitoring (IONM) during shoulder surgeries. Neurodiagn J. 2020;60(2):96–112. https://doi.org/10.1080/21646821.2020.1743952 .
doi: 10.1080/21646821.2020.1743952
pubmed: 32298207
Jahangiri FR. Somatosensory evoked potentials. In: Jahangiri FR, editor. Surgical neurophysiology, a reference guide to intraoperative neurophysiological monitoring. 2nd ed. Seattle: CreateSpace Independent Publishing Platform (Kindle Direct Publishing); 2012. p. 97.
Overzet K, Mora D, Faust E, Krisko L, Welch D, Jahangiri FR. Distal stimulation site at the medial tibia for saphenous nerve somatosensory evoked potentials (DSn-SSEPs) in lateral lumbar spine procedures. Neurodiagn J. 2021;61(2):72–85. https://doi.org/10.1080/21646821.2021.1903277 .
doi: 10.1080/21646821.2021.1903277
pubmed: 33950781
Silverstein J, Mermelstein L, DeWal H, Basra S. Saphenous nerve somatosensory evoked potentials: a novel technique to monitor the femoral nerve during transpsoas lumbar lateral interbody fusion. Spine (Phila Pa 1976). 2014;39(15):1254–60. https://doi.org/10.1097/BRS.0000000000000357 .
doi: 10.1097/BRS.0000000000000357
pubmed: 24732850
Sánchez Roldán M, Mora Granizo F, Oflidis V, Margetis K, Téllez M, Ulkatan S, et al. Optimizing the methodology for saphenous nerve somatosensory evoked potentials for monitoring upper lumbar roots and femoral nerve during lumbar spine surgery: technical note. J Clin Monit Comput. 2022;36(4):1079–85. https://doi.org/10.1007/s10877-021-00737-6 .
doi: 10.1007/s10877-021-00737-6
pubmed: 34213721
Skinner SA, Vodušek DB. Intraoperative recording of the bulbocavernosus reflex. J Clin Neurophysiol. 2014;31(4):313–22. https://doi.org/10.1097/WNP.0000000000000054 .
doi: 10.1097/WNP.0000000000000054
pubmed: 25083842
Minahan RE, Mandir AS. Neurophyiologic intraoperative monitoring of trigeminal and facial nerves. J Clin Neurophysiol. 2011;28(6):551–65. https://doi.org/10.1097/WNP.0b013e318241de1a .
doi: 10.1097/WNP.0b013e318241de1a
pubmed: 22146362
Malcharek MJ, Landgraf J, Hennig G, Sorge O, Aschermann J, Sablotzki A. Recordings of long-latency trigeminal somatosensory-evoked potentials in patients under general anaesthesia. Clin Neurophysiol. 2011;122(5):1048–54. https://doi.org/10.1016/j.clinph.2010.08.017 .
doi: 10.1016/j.clinph.2010.08.017
pubmed: 20965778
Winfree CJ, Kline DG. Intraoperative positioning nerve injuries. Surg Neurol. 2005;63(1):5–18, discussion 18. https://doi.org/10.1016/j.surneu.2004.03.024 .
Silverstein JW, Madhok R, Frendo CD, DeWal H, Lee GR. Contemporaneous evaluation of intraoperative ulnar and median nerve somatosensory evoked potentials for patient positioning: a review of four cases. Neurodiagn J. 2016;56(2):67–82. https://doi.org/10.1080/21646821.2016.1162056 .
doi: 10.1080/21646821.2016.1162056
pubmed: 27373054
Kroll DA, Caplan RA, Posner K, Ward RJ, Cheney FW. Nerve injury associated with anesthesia. Anesthesiology. 1990;73(2):202–7. https://doi.org/10.1097/00000542-199008000-00002 .
doi: 10.1097/00000542-199008000-00002
pubmed: 2382845
Kamel I, Barnette R. Positioning patients for spine surgery: avoiding uncommon position-related complications. World J Orthop. 2014;5(4):425–43. https://doi.org/10.5312/wjo.v5.i4.425 .
doi: 10.5312/wjo.v5.i4.425
pubmed: 25232519
pmcid: 4133449
Overzet K, Wang C, Jahangiri JR. The incidence of positioning-related intraoperative neurophysiological monitoring (IONM) changes: a review of 5894 surgeries. EC Neurol. 2019;11(1):46–54.
MacDonald DB, Al-Zayed Z, Stigsby B, Al-Homoud I. Median somatosensory evoked potential intraoperative monitoring: recommendations based on signal-to-noise ratio analysis. Clin Neurophysiol. 2009;120(2):315–28. https://doi.org/10.1016/j.clinph.2008.10.154 .
doi: 10.1016/j.clinph.2008.10.154
pubmed: 19111507
Acharya JN, Hani A, Cheek J, Thirumala P, Tsuchida TN. American Clinical Neurophysiology Society Guideline 2: guidelines for standard electrode position nomenclature. J Clin Neurophysiol. 2016;33(4):308–11. https://doi.org/10.1097/WNP.0000000000000316 .
doi: 10.1097/WNP.0000000000000316
pubmed: 27482794
American Clinical Neurophysiology Society. Guideline 9A: guidelines on evoked potentials. J Clin Neurophysiol. 2006;23(2):125–37. https://doi.org/10.1097/00004691-200604000-00010 .
doi: 10.1097/00004691-200604000-00010
Allison DW, Balzer JR. Misconceptions in IONM Part I: interleaved intraoperative somatosensory evoked potential stimulation. Neurodiagn J. 2022;62(1):6–25. https://doi.org/10.1080/21646821.2022.2010471 .
doi: 10.1080/21646821.2022.2010471
pubmed: 35061974
Nuwer MR. Evoked potential monitoring in the operating room. New York: Raven Press; 1986.
Merrill DR, Bikson M, Jefferys JG. Electrical stimulation of excitable tissue: design of efficacious and safe protocols. J Neurosci Methods. 2005;141(2):171–98. https://doi.org/10.1016/j.jneumeth.2004.10.020 .
doi: 10.1016/j.jneumeth.2004.10.020
pubmed: 15661300
MacDonald DB, Seidel K, Shils JL. Safety. In: Deletis V, Shils J, Sala F, Seidel K, editors. Neuropphysiology in neurosurgery: a modern approach. 2nd ed. Cambridge: Academic Press; 2020. p. 581–96.
doi: 10.1016/B978-0-12-815000-9.00041-1
Stecker MM. Generalized averaging and noise levels in evoked responses. Comput Biol Med. 2000;30(5):247–65. https://doi.org/10.1016/s0010-4825(00)00012-3 .
doi: 10.1016/s0010-4825(00)00012-3
pubmed: 10913772
Dimakopoulos V, Selmin G, Regli L, Sarnthein J. Optimization of signal-to-noise ratio in short-duration SEP recordings by variation of stimulation rate. Clin Neurophysiol. 2023;150:89–97. https://doi.org/10.1016/j.clinph.2023.03.008 .
doi: 10.1016/j.clinph.2023.03.008
pubmed: 37030046
Banoub M, Tetzlaff JE, Schubert A. Pharmacologic and physiologic influences affecting sensory evoked potentials: implications for perioperative monitoring. Anesthesiology. 2003;99(3):716–37. https://doi.org/10.1097/00000542-200309000-00029 .
doi: 10.1097/00000542-200309000-00029
pubmed: 12960558
Calder HB, Mast J. Sciatic nerve monitoring in acetabular surgeries. Am J EEG Technol. 1995;35(2):113–34.
doi: 10.1080/00029238.1995.11080509
Betts DC, Radue L. The effects of positioning the operative limb on tibial and fibular nerve somatosensory responses during acetabulum fracture repair: A report of two unusual cases. Neurodiagn J. 2016;56(3):151–64. https://doi.org/10.1080/21646821.2016.1202706 .
doi: 10.1080/21646821.2016.1202706
pubmed: 28436774
MacDonald DB, Al Zayed Z, Stigsby B. Tibial somatosensory evoked potential intraoperative monitoring: recommendations based on signal to noise ratio analysis of popliteal fossa, optimized P37, standard P37, and P31 potentials. Clin Neurophysiol. 2005;116(8):1858–69. https://doi.org/10.1016/j.clinph.2005.04.018 .
doi: 10.1016/j.clinph.2005.04.018
pubmed: 16005261
Lagerlund TD, Rubin DI. Volume conduction in clinical neurophysiology. In: Rubin DI, editor. Clinical neurophysiology. 5th ed. New York: Oxford University Press; 2021. p. 1001–18.
Kimura J. Somartosensory evoked potential. In: Kimura J, editor. Electrodiagnosis in diseases of nerve and muscle: principles and practice. 4th ed. Oxford: Oxford University Press; 2013. p. 477–524.
doi: 10.1093/med/9780199738687.003.0019
Yamada T. Neuroanatomic substrates of lower extremity somatosensory evoked potentials. J Clin Neurophysiol. 2000;17(3):269–79. https://doi.org/10.1097/00004691-200005000-00005 .
doi: 10.1097/00004691-200005000-00005
pubmed: 10928639
Çakmur R, Towle VL, Mullan JF, Suarez D, Spire JP. Intra-operative localization of sensorimotor cortex by cortical somatosensory evoked potentials: from analysis of waveforms to dipole source modeling. Acta Neurochir (Wien). 1997;139(12):1117–24, discussion 1124–5. https://doi.org/10.1007/BF01410971 .
Jahangiri FR, Pautler K, Watters K, Anjum SS, Bennett GL. Mapping of the somatosensory cortex Cureus. 2020;12(3): e7332. https://doi.org/10.7759/cureus.7332 .
doi: 10.7759/cureus.7332
pubmed: 32313773
Daube JR. Physiology. In: Handbook of clinical neurophysiology. Amsterdam: Elsevier; 2008. p. 7–43.
Restuccia D. Anatomic origin of P13 and P14 scalp far-field potentials. J Clin Neurophysiol. 2000;17(3):246–57. https://doi.org/10.1097/00004691-200005000-00003 .
doi: 10.1097/00004691-200005000-00003
pubmed: 10928637
Mauguière F. Anatomic origin of the cervical N13 potential evoked by upper extremity stimulation. J Clin Neurophysiol. 2000;17(3):236–45. https://doi.org/10.1097/00004691-200005000-00002 .
doi: 10.1097/00004691-200005000-00002
pubmed: 10928636
Fujimoto H, Kaneko K, Taguchi T, Ofuji A, Yonemura H, Kawai S. Differential recording of upper and lower cervical N13 responses and their contribution to scalp recorded responses in median nerve somatosensory evoked potentials. J Neurol Sci. 2001;187(1–2):17–26. https://doi.org/10.1016/s0022-510x(01)00509-3 .
doi: 10.1016/s0022-510x(01)00509-3
pubmed: 11440740
Allison T, Goff WR, Williamson PD, Van Gilder JC. On the neural origin of early components of the human somatosensory evoked potentials. In: Desmedt JE, editor. Clinical uses of cerebral brainstem and spinal somatosensory evoked potentials, vol. 7. Basel: Karger; 1980. p. 51–68.
Tomberg C, Desmedt JE, Ozaki I, Noël P. Nasopharyngeal recordings of somatosensory evoked potentials document the medullary origin of the N18 far-field. Electroencephalogr Clin Neurophysiol. 1991;80(6):496–503. https://doi.org/10.1016/0168-5597(91)90131-g .
doi: 10.1016/0168-5597(91)90131-g
pubmed: 1720725
Desmedt JE, Cheron G. Non-cephalic reference recording of early somatosensory potentials to finger stimulation in adult or aging normal man: differentiation of widespread N18 and contralateral N20 from the prerolandic P22 and N30 components. Electroencephalogr Clin Neurophysiol. 1981;52(6):553–70. https://doi.org/10.1016/0013-4694(81)91430-9 .
doi: 10.1016/0013-4694(81)91430-9
pubmed: 6172255
Desmedt JE, Cheron G. Central somatosensory conduction in man: neural generators and interpeak latencies of the far-field components recorded from neck and right or left scalp and earlobes. Electroencephalogr Clin Neurophysiol. 1980;50(5–6):382–403. https://doi.org/10.1016/0013-4694(80)90006-1 .
doi: 10.1016/0013-4694(80)90006-1
pubmed: 6160982
Vanderzant CW, Beydoun AA, Domer PA, Hood TW, Abou-Khalil BW. Polarity reversal of N20 and P23 somatosensory evoked potentials between scalp and depth recordings. Electroencephalogr Clin Neurophysiol. 1991;78(3):234–9. https://doi.org/10.1016/0013-4694(91)90038-6 .
doi: 10.1016/0013-4694(91)90038-6
pubmed: 1707796
Watson JC, Rubin DI. Somatosensory evoked potentials. In: Rubin DI, editor. Clinical neurophysiology (contemporary neurology series). 5th ed. New York: Oxford University Press; 2021. p. 683–718.
MacDonald DB, Streletz L, Al-Zayed Z, Abdool B, Stigsby B. Intraoperative neurophysiologic discovery of uncrossed sensory and motor pathways in a patient with horizontal gaze palsy and scoliosis. Clin Neurophysiol. 2004;115(3):576–82. https://doi.org/10.1016/j.clinph.2003.10.029 .
doi: 10.1016/j.clinph.2003.10.029
pubmed: 15036053
Allison T. Localization of sensorimotor cortex in neurosurgery by recording of somatosensory evoked potentials. Yale J Biol Med. 1987;60(2):143–50.
pubmed: 3577212
pmcid: 2590330
Rauschenbach L, Santos AN, Dinger TF, Herten A, Darkwah Oppong M, Schmidt B, et al. Predictive value of intraoperative neuromonitoring in brainstem cavernous malformation surgery. World Neurosurg. 2021;156:e359–73. https://doi.org/10.1016/j.wneu.2021.09.064 .
doi: 10.1016/j.wneu.2021.09.064
pubmed: 34560298
Jorge A, Zhou J, Dixon EC, Hamilton KD, Balzer J, Thirumala P. Area under the curve of somatosensory evoked potentials detects spinal cord injury. J Clin Neurophysiol. 2019;36(2):155–60. https://doi.org/10.1097/WNP.0000000000000563 .
doi: 10.1097/WNP.0000000000000563
pubmed: 30694945
Kashkoush A, Nguyen C, Balzer J, Habeych M, Crammond D, Thirumala P. Diagnostic accuracy of somatosensory evoked potentials during intracranial aneurysm clipping for perioperative stroke. J Clin Monit Comput. 2020;34(4):811–9. https://doi.org/10.1007/s10877-019-00369-x .
doi: 10.1007/s10877-019-00369-x
pubmed: 31399827
Goryawala M, Yaylali I, Cabrerizo M, Vedala K, Adjouadi M. An effective intra-operative neurophysiological monitoring scheme for aneurysm clipping and spinal fusion surgeries. J Neural Eng. 2012;9(2): 026021. https://doi.org/10.1088/1741-2560/9/2/026021 .
doi: 10.1088/1741-2560/9/2/026021
pubmed: 22419062
Cracco JB, Bosch VV, Cracco RQ. Cerebral and spinal somatosensory evoked potentials in children with CNS degenerative disease. Electroencephalogr Clin Neurophysiol. 1980;49(5–6):437–45. https://doi.org/10.1016/0013-4694(80)90386-7 .
doi: 10.1016/0013-4694(80)90386-7
pubmed: 6158425
Cracco JB. Somatosensory evoked potentials in infants and children. J Child Neurol. 1989;4(1):70–2. https://doi.org/10.1177/088307388900400101 .
doi: 10.1177/088307388900400101
Gilmore R. Somatosensory evoked potential testing in infants and children. J Clin Neurophysiol. 1992;9(3):324–41. https://doi.org/10.1097/00004691-199207010-00002 .
doi: 10.1097/00004691-199207010-00002
pubmed: 1517402
Levy SR. Somatosensory evoked potentials in pediatrics. In: Chiappa KH, editor. Evoked potentials in clinical medicine. 3rd ed. Philadelphia: Lippincott-Raven; 1997. p. 453–67.
Yakovlev PI, Lecours A. The myelogenetic cycles of regional maturation of the brain. In: Minkowski A, editor. Regional development of the brain in early life. Oxford: Blackwell Scientific; 1967. p. 3–70.
Voitenkov VB, Klimkin AV, Skripchenko NV, Gerasimov AP, Aksenova AI. Age-related dynamics of the parameters of somatosensory evoked potentials in healthy children. Hum Physiol. 2017;43(4):391–4. https://doi.org/10.1134/S0362119717040156 .
doi: 10.1134/S0362119717040156
Muengtaweepongsa S, Legatt A, Murro AM. General principles of somatosensory evoked potentials. Medscape, Neurology. 2019. https://emedicine.medscape.com/article/1139906-overview?form=fpf . Accessed 24 Apr 2024.
Majnemer A, Rosenblatt B, Willis D, Lavallee J. The effect of gestational age at birth on somatosensory-evoked potentials performed at term. J Child Neurol. 1990;5(4):329–35. https://doi.org/10.1177/088307389000500412 .
doi: 10.1177/088307389000500412
pubmed: 2246487
Smit BJ, Ongerboer de Visser BW, de Vries LS, Dekker FW, Kok JH. Somatosensory evoked potentials in very preterm infants. Clin Neurophysiol. 2000;111(5):901–8. https://doi.org/10.1016/s1388-2457(00)00245-5 .
doi: 10.1016/s1388-2457(00)00245-5
pubmed: 10802462
Sloan TB, Heyer EJ. Anesthesia for intraoperative neurophysiologic monitoring of the spinal cord. J Clin Neurophysiol. 2002;19(5):430–43. https://doi.org/10.1097/00004691-200210000-00006 .
doi: 10.1097/00004691-200210000-00006
pubmed: 12477988
Alkire MT, Hudetz AGTG. Consciousness and anesthesia. Science. 2008;322(5903):876–80. https://doi.org/10.1126/science.1149213 .
doi: 10.1126/science.1149213
pubmed: 18988836
pmcid: 2743249
Sloan TB. Anesthetic effects on electrophysiologic recordings. J Clin Neurophysiol. 1998;15(3):217–26. https://doi.org/10.1097/00004691-199805000-00005 .
doi: 10.1097/00004691-199805000-00005
pubmed: 9681559
Rabai F, Mohamed B, Seubert CN. Optimizing intraoperative neuromonitoring: anesthetic considerations. Curr Anesthesiol Rep. 2018;8:306–17. https://doi.org/10.1007/s40140-018-0281-6 .
doi: 10.1007/s40140-018-0281-6
Keenan JE, Benrashid E, Kale E, Nicoara A, Husain AM, Hughes GC. Neurophysiological intraoperative monitoring during aortic arch surgery. Semin Cardiothorac Vasc Anesth. 2016;20(4):273–82. https://doi.org/10.1177/1089253216672441 .
doi: 10.1177/1089253216672441
pubmed: 27708177
Sloan T, Sloan H, Rogers J. Nitrous oxide and isoflurane are synergistic with respect to amplitude and latency effects on sensory evoked potentials. J Clin Monit Comput. 2010;24(2):113–23. https://doi.org/10.1007/s10877-009-9219-3 .
doi: 10.1007/s10877-009-9219-3
pubmed: 20063047
Tamkus AA, Rice KS, Kim HL. Differential rates of false-positive findings in transcranial electric motor evoked potential monitoring when using inhalational anesthesia versus total intravenous anesthesia during spine surgeries. Spine J. 2014;14(8):1440–6. https://doi.org/10.1016/j.spinee.2013.08.037 .
doi: 10.1016/j.spinee.2013.08.037
pubmed: 24209393
Wilent WB, Tesdahl EA, Trott JT, Tassone S, Harrop JS, Klineberg EO, et al. Impact of inhalational anesthetic agents on the baseline monitorability of motor evoked potentials during spine surgery: a review of 22,755 cervical and lumbar procedures. Spine J. 2021;21(11):1839–46. https://doi.org/10.1016/j.spinee.2021.07.002 .
doi: 10.1016/j.spinee.2021.07.002
pubmed: 34274500
Lieberman JA, Feiner J, Rollins M, Lyon R, Jasiukaitis P. Changes in transcranial motor evoked potentials during hemorrhage are associated with increased serum propofol concentrations. J Clin Monit Comput. 2018; 32(3): 541–8 Erratum in: J Clin Monit Comput. 2018;32(3):581. https://doi.org/10.1007/s10877-017-0057-4 .
Skibiski J, Abdijadid S. Barbiturates. Stat Pearls [internet]. 2023 (Updated 2022 Dec 31]. https://www.ncbi.nlm.nih.gov//books//NBK539731/ . Accessed 26 Jan 2024.
Sloan TB, Vasquez J, Burger E. Methohexital in total intravenous anesthesia during intraoperative neurophysiological monitoring. J Clin Monit Comput. 2013;27(3):697–702. https://doi.org/10.1007/s10877-013-9490-1 .
doi: 10.1007/s10877-013-9490-1
pubmed: 23813116
Sneyd JR, Gambus PL, Rigby-Jones AE. Current status of perioperative hypnotics, role of benzodiazepines, and the case for remimazolam: a narrative review. Br J Anaesth. 2021;127(1):41–55. https://doi.org/10.1016/j.bja.2021.03.028 .
doi: 10.1016/j.bja.2021.03.028
pubmed: 33965206
Sloan TB, Fugina ML, Toleikis JR. Effects of midazolam on median nerve somatosensory evoked potentials. Br J Anaesth. 1990;64(5):590–3. https://doi.org/10.1093/bja/64.5.590 .
doi: 10.1093/bja/64.5.590
pubmed: 2354098
Kondo T, Toyota Y, Narasaki S, Watanabe T, Miyoshi H, Saeki N, et al. Intraoperative responses of motor evoked potentials to the novel intravenous anesthetic remimazolam during spine surgery: a report of two cases. JA Clin Rep. 2020;6(1):97. https://doi.org/10.1186/s40981-020-00401-z .
doi: 10.1186/s40981-020-00401-z
pubmed: 33300097
pmcid: 7726079
Meng XL, Wang LW, Zhao W, Guo XY. Effects of different etomidate doses on intraoperative somatosensory-evoked potential monitoring. Ir J Med Sci. 2015;184(4):799–803. https://doi.org/10.1007/s11845-014-1174-4 .
doi: 10.1007/s11845-014-1174-4
pubmed: 25060967
Sloan TB, Ronai AK, Toleikis JR, Koht A. Improvement of intraoperative somatosensory evoked potentials by etomidate. Anesth Analg. 1988;67(6):582–5.
pubmed: 3132058
doi: 10.1213/00000539-198806000-00016
Rajan S, Devarajan J, Krishnaney A, George A, Rasoul JJ, Avitsian R. Opioid alternatives in spine surgery: a narrative review. J Neurosurg Anesthesiol. 2022;34(1):3–13. https://doi.org/10.1097/ANA.0000000000000708 .
doi: 10.1097/ANA.0000000000000708
pubmed: 32568816
Ma K, Bebawy JF, Hemmer LB. Multimodal analgesia and intraoperative neuromonitoring. J Neurosurg Anesthesiol. 2023;35(2):172–6. https://doi.org/10.1097/ANA.0000000000000904 .
doi: 10.1097/ANA.0000000000000904
pubmed: 36662721
Schubert A, Licina MG, Lineberry PJ. The effect of ketamine on human somatosensory evoked potentials and its modification by nitrous oxide. Anesthesiology. 1990;72(1):33–9. https://doi.org/10.1097/00000542-199001000-00007 .
doi: 10.1097/00000542-199001000-00007
pubmed: 2297131
Furutani K, Deguchi H, Matsuhashi M, Mitsuma Y, Kamiya Y, Baba H. A bolus dose of ketamine reduces the amplitude of the transcranial electrical motor-evoked potential: a randomized, double-blinded, placebo-controlled study. J Neurosurg Anesthesiol. 2021;33(3):230–8. https://doi.org/10.1097/ANA.0000000000000653 .
doi: 10.1097/ANA.0000000000000653
pubmed: 31633576
Bala E, Sessler DI, Nair DR, McLain R, Dalton JE, Farag E. Motor and somatosensory evoked potentials are well maintained in patients given dexmedetomidine during spine surgery. Anesthesiology. 2008;109(3):417–25. https://doi.org/10.1097/ALN.0b013e318182a467 .
doi: 10.1097/ALN.0b013e318182a467
pubmed: 18719439
Tobias JD, Goble TJ, Bates G, Anderson JT, Hoernschemeyer DG. Effects of dexmedetomidine on intraoperative motor and somatosensory evoked potential monitoring during spinal surgery in adolescents. Paediatr Anaesth. 2008;18(11):1082–8. https://doi.org/10.1111/j.1460-9592.2008.02733.x .
doi: 10.1111/j.1460-9592.2008.02733.x
pubmed: 18717802
Li Y, Meng L, Peng Y, Qiao H, Guo L, Han R, et al. Effects of dexmedetomidine on motor- and somatosensory-evoked potentials in patients with thoracic spinal cord tumor: a randomized controlled trial. BMC Anesthesiol. 2016;16(1):51. https://doi.org/10.1186/s12871-016-0217-y .
doi: 10.1186/s12871-016-0217-y
pubmed: 27484701
pmcid: 4970285
Lee WH, Park CK, Park HP, Kim SM, Oh BM, Kim K, et al. Effect of dexmedetomidine combined anesthesia on motor evoked potentials during brain tumor surgery. World Neurosurg. 2019;123:e280–7.
pubmed: 30496923
doi: 10.1016/j.wneu.2018.11.152
Jiang X, Tang X, Liu S, Liu L. Effects of dexmedetomidine on evoked potentials in spinal surgery under combined intravenous inhalation anesthesia: a randomized controlled trial. BMC Anesthesiol. 2023;23(1):36. https://doi.org/10.1186/s12871-023-01990-9 .
doi: 10.1186/s12871-023-01990-9
pubmed: 36721105
pmcid: 9887773
Liu T, Qin Y, Qi H, Luo Z, Yan L, Yu P, et al. A loading dose of dexmedetomidine with constant infusion inhibits intraoperative neuromonitoring during thoracic spinal decompression surgery: a randomized prospective study. Front Pharmacol. 2022;13: 840320. https://doi.org/10.3389/fphar.2022.840320 .
doi: 10.3389/fphar.2022.840320
pubmed: 35330828
pmcid: 8940210
Alvarez-Jimenez R, Weerink MAS, Hannivoort LN, Su H, Struys MMRF, Loer SA, et al. Dexmedetomidine clearance decreases with increasing drug exposure: Implications for current dosing regimens and target-controlled infusion models assuming linear pharmacokinetics. Anesthesiology. 2022;136(2):279–92. https://doi.org/10.1097/ALN.0000000000004049 .
doi: 10.1097/ALN.0000000000004049
pubmed: 34851425
Sloan TB, Mongan P, Lyda C, Koht A. Lidocaine infusion adjunct to total intravenous anesthesia reduces the total dose of propofol during intraoperative neurophysiological monitoring. J Clin Monit Comput. 2014;28(2):139–47. https://doi.org/10.1007/s10877-013-9506-x .
doi: 10.1007/s10877-013-9506-x
pubmed: 23996498
Liu M, Wang N, Wang D, Liu J, Zhou X, Jin W. Effect of low-dose lidocaine on MEPs in patients undergoing intracranial tumor resection with propofol anesthesia: a randomized controlled trial. Medicine (Baltimore). 2022;101(32): e29965. https://doi.org/10.1097/MD.0000000000029965 .
doi: 10.1097/MD.0000000000029965
pubmed: 35960044
Urban MK, Fields K, Donegan SW, Beathe JC, Pinter DW, Boachie-Adjei O, et al. A randomized crossover study of the effects of lidocaine on motor- and sensory-evoked potentials during spinal surgery. Spine J. 2017;17(12):1889–96. https://doi.org/10.1016/j.spinee.2017.06.024 .
doi: 10.1016/j.spinee.2017.06.024
pubmed: 28666848
Murphy GS, Szokol JW, Avram MJ, Greenberg SB, Shear TD, Deshur MA, et al. Clinical effectiveness and safety of intraoperative methadone in patients undergoing posterior spinal fusion surgery: a randomized, double-blinded, controlled trial. Anesthesiology. 2017;126(5):822–33. https://doi.org/10.1097/ALN.0000000000001609 .
doi: 10.1097/ALN.0000000000001609
pubmed: 28418966
Kharasch ED. Intraoperative methadone: rediscovery, reappraisal, and reinvigoration? Anesth Analg. 2011;12(1):13–6. https://doi.org/10.1213/ANE.0b013e3181fec9a3 .
doi: 10.1213/ANE.0b013e3181fec9a3
Higgs M, Hackworth RJ, John K, Riffenburgh R, Tomlin J, Wamsley B. The intraoperative effect of methadone on somatosensory evoked potentials. J Neurosurg Anesthesiol. 2017;29(2):168–74. https://doi.org/10.1097/ANA.0000000000000265 .
doi: 10.1097/ANA.0000000000000265
pubmed: 26669838
Pathak KS, Brown RH, Cascorbi HF, Nash CL Jr. Effects of fentanyl and morphine on intraoperative somatosensory cortical-evoked potentials. Anesth Analg. 1984;63(9):833–7.
pubmed: 6465579
doi: 10.1213/00000539-198409000-00009
Hemmer LB, Zeeni C, Bebawy JF, Bendok BR, Cotton MA, Shah NB, et al. The incidence of unacceptable movement with motor evoked potentials during craniotomy for aneurysm clipping. World Neurosurg. 2014;81(1):99–104. https://doi.org/10.1016/j.wneu.2012.05.034 .
doi: 10.1016/j.wneu.2012.05.034
pubmed: 23043993
Asouhidou I, Katsaridis V, Vaidis G, Ioannou P, Givissis P, Christodoulou A, et al. Somatosensory evoked potentials suppression due to remifentanil during spinal operations. A prospective clinical study. Scoliosis. 2010;5(8):1–6. https://doi.org/10.1186/1748-7161-5-8 .
doi: 10.1186/1748-7161-5-8
Owolabi LF, Adebisi SS, Danborno BS, Buraimoh AA. Median nerve conduction in healthy Nigerians: normative data. Ann Med Health Sci Res. 2016;6(2):85–9.
pubmed: 27213090
pmcid: 4866372
doi: 10.4103/2141-9248.181839
Chen JH, Shilian P, Cheongsiatmoy J, Gonzalez AA. Factors associated with inadequate intraoperative baseline lower extremity somatosensory evoked potentials. J Clin Neurophysiol. 2018;35(5):426–30. https://doi.org/10.1097/WNP.0000000000000494 .
doi: 10.1097/WNP.0000000000000494
pubmed: 29933262
Koht A, Sloan TB, Hemmer LB. UptoDate [Online]. Waltham, MA: Crowley; 2022. https://www.uptodate.com/contents/neuromonitoring-in-surgery-and-anesthesia . Accessed 24 Apr 2022.
Gonzalez AA, Droker BS, Kim ES, Parikh P. Success rate of obtaining baseline somatosensory and motor evoked potentials in 695 consecutive cranial and spine surgeries. J Clin Neurophysiol. 2022;39(6):513–8. https://doi.org/10.1097/WNP.0000000000000796 .
doi: 10.1097/WNP.0000000000000796
pubmed: 33273155
Deiner S. Highlights of anesthetic considerations for intraoperative neuromonitoring. Semin Cardiothorac Vasc Anesth. 2010;14(1):51–3. https://doi.org/10.1177/1089253210362792 .
doi: 10.1177/1089253210362792
pubmed: 20472627
Jameson LC, Sloan TB. Monitoring of the brain and spinal cord. Anesthesiol Clin. 2006;24(4):777–91. https://doi.org/10.1016/j.atc.2006.08.002 .
doi: 10.1016/j.atc.2006.08.002
pubmed: 17342964
Cui H, Luk KD, Hu Y, Cui H, Luk LD, Hu Y. Effects of physiological parameters on intraoperative somatosensory-evoked potential monitoring: results of a multifactor analysis. Med Sci Monit. 2009;15(5):CR226–30.
pubmed: 19396037
Stecker MM, Cheung AT, Pochettino A, Kent G, Patterson T, Weiss SJ, et al. Deep hypothermic circulatory arrest: I. Effects of cooling on electroencephalogram and evoked potentials. Ann Thorac Surg. 2001;71(1):14–21. https://doi.org/10.1016/s0003-4975(00)01592-7 .
doi: 10.1016/s0003-4975(00)01592-7
pubmed: 11216734
Zanatta P, Bosco E, Comin A, Mazzarolo AP, Di Pasquale P, Fort IA, et al. Effect of mild hypothermic cardiopulmonary bypass on the amplitude of somatosensory-evoked potentials. J Neurosurg Anesthesiol. 2014;26(2):161–6. https://doi.org/10.1097/ANA.0000000000000016 .
doi: 10.1097/ANA.0000000000000016
pubmed: 24492514
Madhok J, Wu D, Xiong W, Geocadin RG, Jia X. Hypothermia amplifies somatosensory-evoked potentials in uninjured rats. J Neurosurg Anesthesiol. 2012;24(3):197–202. https://doi.org/10.1097/ANA.0b013e31824ac36c .
doi: 10.1097/ANA.0b013e31824ac36c
pubmed: 22441433
pmcid: 3372632
Ghariani S, Liard L, Spaey J, Noirhomme PH, El Khoury GA, de Tourtchaninoff M, et al. Retrospective study of somatosensory evoked potential monitoring in deep hypothermic circulatory arrest. Ann Thorac Surg. 1999;67(6):1915–18; discussion 1919–21. https://doi.org/10.1016/s0003-4975(99)00413-0 .
Ghariani S, Matta A, Dion R, Guérit JM. Intra- and postoperative factors determining neurological complications after surgery under deep hypothermic circulatory arrest: a retrospective somatosensory evoked potential study. Clin Neurophysiol. 2000;111(6):1082–94. https://doi.org/10.1016/s1388-2457(00)00261-3 .
doi: 10.1016/s1388-2457(00)00261-3
pubmed: 10825716
Nuwer MR. Intraoperative electroencephalography. J Clin Neurophysiol. 1993;10(4):437–44. https://doi.org/10.1097/00004691-199310000-00005 .
doi: 10.1097/00004691-199310000-00005
pubmed: 8308142
Prior PF. EEG Monitoring and evoked potentials in brain ischemia. Br J Anaesth. 1985;57(1):63–81. https://doi.org/10.1093/bja/57.1.63 .
doi: 10.1093/bja/57.1.63
pubmed: 3881115
Branston NM, Symon L. Cortical EP, blood flow, and potassium changes in experimental ischemia. In: Barber C, editor. Evoked potentials. Baltimore: University Park Press; 1980. p. 527–30.
doi: 10.1007/978-94-011-6645-4_61
Yang J, Skaggs DL, Chan P, Shah SA, Vitale MG, Neiss G, et al. Raising mean arterial pressure alone restores 20% of intraoperative neuromonitoring losses. Spine (Phila Pa 1976). 2018;43(13):890–4. https://doi.org/10.1097/BRS.0000000000002461 .
doi: 10.1097/BRS.0000000000002461
pubmed: 29049087
Singh G. Somatosensory evoked potential monitoring. J Neuroanaesthesiol Crit Care. 2016;3(4):S97-104. https://doi.org/10.4103/2348-0548.174745 .
doi: 10.4103/2348-0548.174745
Werndle MC, Saadoun S, Phang I, Czosnyka M, Varsos GV, Czosnyka ZH, et al. Monitoring of spinal cord perfusion pressure in acute spinal cord injury: initial findings of the injured spinal cord pressure evaluation study. Crit Care Med. 2014;42(3):646–55. https://doi.org/10.1097/CCM.0000000000000028 .
doi: 10.1097/CCM.0000000000000028
pubmed: 24231762
Ledsome JR, Cole C, Sharp-Kehl JM. Somatosensory evoked potentials during hypoxia and hypocapnia in conscious humans. Can J Anaesth. 1996;43(10):1025–9. https://doi.org/10.1007/BF03011904 .
doi: 10.1007/BF03011904
pubmed: 8896854
Schubert A, Drummond JC. The effect of acute hypocapnia on human median nerve somatosensory evoked responses. Anesth Analg. 1986;65(3):240–4.
pubmed: 3082246
doi: 10.1213/00000539-198603000-00004
Kalkman CJ, Baezeman EH, Ribberink AA, Oosting J, Deen L, Bovill JG. Influence of changes in arterial carbon dioxide tension on the electroencephalogram and posterior tibial nerve somatosensory cortical evoked potentials during alfentanil/nitrous oxide anesthesia. Anesthesiology. 1991;75(1):68–74. https://doi.org/10.1097/00000542-199107000-00012 .
doi: 10.1097/00000542-199107000-00012
pubmed: 1905885
Kanda F, Jinnai J, Fujita T. Somatosensory evoked potentials in patients with hypocalcaemia after parathyroidectomy. J Neurol. 1988;235(3):136–9. https://doi.org/10.1007/BF00314302 .
doi: 10.1007/BF00314302
pubmed: 3367159
York DH, Chabot RJ, Gaines RW. Response variability of somatosensory evoked potentials during scoliosis surgery. Spine (Phila Pa 1976). 1987;12(9):864–76. https://doi.org/10.1097/00007632-198711000-00007 .
doi: 10.1097/00007632-198711000-00007
pubmed: 3441833
Apel DM, Marrero G, King J, Tolo VT, Bassett GS. Avoiding paraplegia during anterior spinal surgery: The role of somatosensory evoked potential monitoring with temporary occlusion of segmental spinal arteries. Spine (Phila Pa 1976). 1991;16(8 Suppl):S365-70.
pubmed: 1785089
Coles JG, Wilson GJ, Sima AF, Klement P, Tait GA. Intraoperative detection of spinal cord ischemia using somatosensory cortical evoked potentials during thoracic aortic occlusion. Ann Thor Surg. 1982;34(3):299–306. https://doi.org/10.1016/s0003-4975(10)62499-x .
doi: 10.1016/s0003-4975(10)62499-x
Young W, Mollin D. Intraoperative somatosensory evoked potential monitoring of spinal surgery. In: Desmedt JE, editor. Neuromonitoring in surgery. Amsterdam: Elsevier; 1989. p. 165–73.
Deletis V, Engler GL. Somatosensory evoked potentials for spinal cord monitoring. In: Bridwell KH, DeWald RL, editors. The textbook of spinal surgery. Philadelphia: Lippincott-Raven; 1997. p. 85–92.
Kelleher MO, Tan G, Sarjeant R, Fehlings MG. Predictive value of intraoperative neurophysiological monitoring during cervical spine surgery: a prospective analysis of 1055 consecutive patients. J Neurosurg Spine. 2008;8(3):215–21. https://doi.org/10.3171/SPI/2008/8/3/215 .
doi: 10.3171/SPI/2008/8/3/215
pubmed: 18312072
Sala F, Bricolo A, Faccioli F, Lanteri P, Gerosa M. Surgery for intramedullary spinal cord tumors: the role of intraoperative (neurophysiological) monitoring. Eur Spine J. 2007;16(Suppl 2):S130–9. https://doi.org/10.1007/s00586-007-0423-x .
doi: 10.1007/s00586-007-0423-x
pubmed: 17653776
Macdonald DB, Al Zayed Z, Al SA. Four-limb muscle motor evoked potential and optimized somatosensory evoked potential monitoring with decussation assessment: results in 206 thoracolumbar spine surgeries. Eur Spine J. 2007;6(Suppl 2):s171–87. https://doi.org/10.1007/s00586-007-0426-7 .
doi: 10.1007/s00586-007-0426-7
Hermans H, Lipfert P, Meier S, Jetzek-Zader M, Krauspe R, Stevens MF. Cortical somatosensory-evoked potentials during spine surgery in patients with neuromuscular and idiopathic scoliosis under propofol-remifentanil anaesthesia. Br J Anaesth. 2004;98(3):362–5. https://doi.org/10.1093/bja/ael365 .
doi: 10.1093/bja/ael365
Smith PN, Balzer JR, Khan MH, Davis RA, Crammond D, Welch WC, et al. Intraoperative somatosensory evoked potential monitoring during anterior cervical discectomy and fusion in nonmyelopathic patients—a review of 1039 cases. Spine J. 2007;7(1):83–7. https://doi.org/10.1016/j.spinee.2006.04.008 .
doi: 10.1016/j.spinee.2006.04.008
pubmed: 17197338
Costa P, Bruno A, Bonzanino M, Massaro F, Caruso L, Vincenzo I, et al. Somatosensory- and motor-evoked potential monitoring during spine and spinal cord surgery. Spinal Cord. 2007;45(1):86–91. https://doi.org/10.1038/sj.sc.3101934 .
doi: 10.1038/sj.sc.3101934
pubmed: 16670686
Khan MH, Smith PN, Balzer JR, Crammond D, Welch WC, Gerszten P, et al. Intraoperative somatosensory evoked potential monitoring during cervical spine corpectomy surgery: experience with 508 cases. Spine (Phila Pa 1976). 2006;13(4):E105-13. https://doi.org/10.1097/01.brs.0000200163.71909.1f .
doi: 10.1097/01.brs.0000200163.71909.1f
Weigang E, Hartert M, Siegenthaler MP, Pitzer-Hartert K, Luehr M, Sircar R, et al. Neurophysiological monitoring during thoracoabdominal aortic endovascular stent graft implantation. Eur J Cardiothorac Surg. 2006;29(3):392–6. https://doi.org/10.1016/j.ejcts.2005.11.039 .
doi: 10.1016/j.ejcts.2005.11.039
pubmed: 16439144
Thirumala PD, Bodily L, Tint D, Ward WT, Deeney VF, Crammond DJ, et al. Somatosensory-evoked potential monitoring during instrumented scoliosis corrective procedures; validity revisited. Spine J. 2014;14(8):1572–80. https://doi.org/10.1016/j.spinee.2013.09.035 .
doi: 10.1016/j.spinee.2013.09.035
pubmed: 24361128
Stecker MM. A review of intraoperative monitoring for spinal surgery. Surg Neurol Int. 2012;3(Suppl 3):S174-87. https://doi.org/10.4103/2152-7806.98579 .
doi: 10.4103/2152-7806.98579
pubmed: 22905324
pmcid: 3422092
Dennis GC, Dehkordi O, Millis RM, Cole AN, Brown DS, Paul OA. Monitoring of median nerve somatosensory evoked potentials during cervical spinal cord decompression. J Clin Neurophysiol. 1996;13(1):51–9. https://doi.org/10.1097/00004691-199601000-00005 .
doi: 10.1097/00004691-199601000-00005
pubmed: 8988285
Dinner DS, Lüders H, Lesser RP, Morris HH, Barnett G, Klem G. Intraoperative spinal somatosensory evoked potential monitoring. J Neurosurg. 1986;65(6):807–14. https://doi.org/10.3171/jns.1986.65.6.0807 .
doi: 10.3171/jns.1986.65.6.0807
pubmed: 3772479
Guerit J, Witdoeckt C, Rubay J, Matta A, Dion R. The usefulness of the spinal and subcortical components of the posterior tibial nerve SEPs for spinal cord monitoring during aortic coarctation repair. Electroencephalogr Clin Neurophysiol. 1997;104(2):115–21. https://doi.org/10.1016/s0168-5597(97)96661-2 .
doi: 10.1016/s0168-5597(97)96661-2
pubmed: 9146477
Nuwer MR, Dawson EG, Carlson LG, Kanim LE, Sherman JE. Somatosensory evoked potential spinal cord monitoring reduces neurologic deficits after scoliosis surgery: results of a large multicenter survey. Electroencepholog and Clin Neurophysiol. 1995;96(1):6–11. https://doi.org/10.1016/0013-4694(94)00235-d .
doi: 10.1016/0013-4694(94)00235-d
Robinson LR, Slimp JC, Anderson PA, Stolov WC. The efficacy of femoral nerve intraoperative somatosensory evoked potentials during surgical treatment of thoracolumbar fractures. Spine (Phila Pa 1976). 1993;18(13):1793–7. https://doi.org/10.1097/00007632-199310000-00013 .
doi: 10.1097/00007632-199310000-00013
pubmed: 8235863
Schramm J. Spinal cord monitoring: Current status and new developments. Cent Nerv Syst Trauma. 1985;2(3):207–27. https://doi.org/10.1089/cns.1985.2.207 .
doi: 10.1089/cns.1985.2.207
pubmed: 3914921
Spielholz NI, Benjamin MV, Engler GL, Ransohoff J. Somatosensory evoked potentials during decompression and stabilization of the spine. Methods and findings. Spine (Phila Pa 1976). 1979;4(6):500–5. https://doi.org/10.1097/00007632-197911000-00008 .
doi: 10.1097/00007632-197911000-00008
pubmed: 515841
Spielholz NI. Intraoperative monitoring using somato-sensory evoked potentials: a brief overview. Electromyogr Clin Neurophysiol. 1994;34(1):29–34.
pubmed: 8168454
Park P, Wang AC, Sangala JR, Kim SM, Hervey-Jumper S, Than KD, et al. Impact of multimodal intraoperative monitoring during correction of symptomatic cervical or cervicothoracic kyphosis. J Neurosurg Spine. 2011;14(1):99–105. https://doi.org/10.3171/2010.9.SPINE1085 .
doi: 10.3171/2010.9.SPINE1085
pubmed: 21142458
Malhotra NR, Shaffrey CI. Intraoperative electrophysiological monitoring in spine surgery. Spine (Phila Pa 1976). 2010;35(25):2167–79. https://doi.org/10.1097/BRS.0b013e3181f6f0d0 .
doi: 10.1097/BRS.0b013e3181f6f0d0
pubmed: 21102290
Garcia RM, Qureshi SA, Cassinelli EH, Biro CL, Furey CG, Bohlman HH. Detection of postoperative neurologic deficits using somatosensory-evoked potentials alone during posterior cervical laminoplasty. Spine J. 2010;10(10):890–5.
pubmed: 20869003
doi: 10.1016/j.spinee.2010.08.018
Thuet ED, Winsher JC, Padberg AM, Bridwell KH, Lenke LG, Dobbs MB, et al. Validity and reliability of intraoperative monitoring in pediatric spinal deformity surgery: a 23-year experience of 3436 surgical cases. Spine (Phila Pa 1976). 2010;35(20):1880–6. https://doi.org/10.1016/j.spinee.2010.08.018 .
doi: 10.1016/j.spinee.2010.08.018
pubmed: 20802388
Ayoub C, Zreik T, Sawaya R, Domloj N, Sabbagh A, Skaf G. Significance and cost-effectiveness of somatosensory evoked potential monitoring in cervical spine surgery. Neurol India. 2010;58(3):424–8. https://doi.org/10.4103/0028-3886.66454 .
doi: 10.4103/0028-3886.66454
pubmed: 20644272
Kamerlink JR, Errico T, Xavier S, Patel A, Patel A, Cohen A, et al. Major intraoperative neurologic monitoring deficits in consecutive pediatric and adult spinal deformity patients at one institution. Spine (Phila Pa 1976). 2010;35(2):240–5.
pubmed: 20081520
doi: 10.1097/BRS.0b013e3181c7c8f6
Vitale MG, Moore DW, Matsumoto H, Emerson RG, Booker WA, Gomez JA, et al. Risk factors for spinal cord injury during surgery for spinal deformity. J Bone Jt Surg Am. 2010;92(1):64–71. https://doi.org/10.1097/BRS.0b013e3181c7c8f6 .
doi: 10.1097/BRS.0b013e3181c7c8f6
Gonzalez AA, Jeyanandarajan D, Hansen C, Zada G, Hsieh PC. Intraoperative neurophysiological monitoring during spine surgery: a review. Neurosurg Focus. 2009;27(4):E6. https://doi.org/10.3171/2009.8.FOCUS09150 .
doi: 10.3171/2009.8.FOCUS09150
pubmed: 19795955
Sloan TB, Jameson LC. Electrophysiologic monitoring during surgery to repair the thoraco-abdominal aorta. J Clin Neurophysiol. 2007;24(4):316–27. https://doi.org/10.1097/WNP.0b013e31811ebc66 .
doi: 10.1097/WNP.0b013e31811ebc66
pubmed: 17938600
Devlin VJ, Schwartz DM. Intraoperative neurophysiologic monitoring during spinal surgery. J Am Acad Orthop Surg. 2007;15(9):549–60. https://doi.org/10.5435/00124635-200709000-00005 .
doi: 10.5435/00124635-200709000-00005
pubmed: 17761611
Pajewski TN, Arlet V, Phillips LH. Current approach on spinal cord monitoring: the point of view of the neurologist, the anesthesiologist and the spine surgeon. Eur Spine J. 2007;16(Suppl 2):S115–29. https://doi.org/10.1007/s00586-007-0419-6 .
doi: 10.1007/s00586-007-0419-6
pubmed: 17619913
Roh MS, Wilson-Holden TJ, Padberg AM, Park JB, Daniel RK. The utility of somatosensory evoked potential monitoring during cervical spine surgery: how often does it prompt intervention and affect outcome? Asian Spine J. 2007;1(1):43–7. https://doi.org/10.4184/asj.2007.1.1.43 .
doi: 10.4184/asj.2007.1.1.43
pubmed: 20411152
pmcid: 2857496
Estrera AL, Sheinbaum R, Miller CC, Harrison R, Safi HJ. Neuromonitor-guided repair of thoracoabdominal aortic aneurysms. J Thorac Cardiovasc Surg. 2010;140(6 Suppl):S131–5; discussion S142–6. https://doi.org/10.1016/j.jtcvs.2010.07.058
ter Wolbeek C, Hartert M, Conzelmann LO, Peivandi AA, Czerny M, Gottardi R, et al. Value and pitfalls of neurophysiological monitoring in thoracic and thoracoabdominal aortic replacement and endovascular repair. Thorac Cardiovasc Surg. 2010;58(5):260–4. https://doi.org/10.1055/s-0030-1249904 .
doi: 10.1055/s-0030-1249904
pubmed: 20680900
Lall RR, Lall RR, Hauptman JS, Munoz C, Cybulski GR, Koski T, et al. Intraoperative neurophysiological monitoring in spine surgery: Indications, efficacy, and role of the preoperative checklist. Neurosurg Focus. 2012;33(5):E10. https://doi.org/10.3171/2012.9.FOCUS12235 .
doi: 10.3171/2012.9.FOCUS12235
pubmed: 23116090
Lesser RP, Raudzens P, Lüders H, Nuwer MR, Goldie WD, Morris HH 3rd, Dinner DS, Klem G, Hahn JF, Shetter AG, et al. Postoperative neurological deficits may occur despite unchanged intraoperative somatosensory evoked potentials. Ann Neurol. 1986;19(1):22–5. https://doi.org/10.1002/ana.410190105 .
doi: 10.1002/ana.410190105
pubmed: 3947036
Chatrian GE, Berger MS, Wirch AL. Discrepancy between intraoperative SSEPs and postoperative function. Case report. J Neurosurg. 1988;69(3):450–4. https://doi.org/10.3171/jns.1988.69.3.0450 .
doi: 10.3171/jns.1988.69.3.0450
pubmed: 3404244
Dawson EG, Sherman JE, Kanim LE, Nuwer MR. Spinal cord monitoring. Results of the Scoliosis Research Society and the European Spinal Deformity Society survey. Spine (Phila Pa 1976). 1991;16(8 Suppl):S361-4.
pubmed: 1785088
Minahan RE, Sepkudy JP, Lesser RP, Sponseller PD, Kostuik JP. Anterior spinal cord injury with preserved neurogenic “motor” evoked potentials. Clin Neurophysiol. 2001;112(8):1442–50. https://doi.org/10.1016/s1388-2457(01)00567-3 .
doi: 10.1016/s1388-2457(01)00567-3
pubmed: 11459684
Jones SJ, Buonamassa S, Crockard HA. Two cases of quadriparesis following anterior cervical discectomy with normal perioperative somatosensory evoked potentials. J Neurol Neurosurg Psychiatry. 2003;74(2):273–6. https://doi.org/10.1136/jnnp.74.2.273 .
doi: 10.1136/jnnp.74.2.273
pubmed: 12531970
pmcid: 1738296
Charalampidis A, Jiang F, Wilson JRF, Badhiwala J, Brodke D, Fehlings M. The use of intraoperative neurophysiological monitoring in spine surgery. Glob Spine J. 2020;10(1 Suppl):104S-114S. https://doi.org/10.1177/2192568219859314 .
doi: 10.1177/2192568219859314
Xu R, Ritzl EK, Sait M, Sciubba DM, Wolinsky JP, Witham TF, et al. A role for motor and somatosensory evoked potentials during anterior cervical discectomy and fusion for patients without myelopathy: analysis of 57 consecutive cases. Surg Neurol. 2011;2:133.
doi: 10.4103/2152-7806.85606
Epstein NE. The need to add motor evoked potential monitoring to somatosensory and electromyographic monitoring in cervical spine surgery. Surg Neurol Int. 2013;4(Suppl 5):S383–91. https://doi.org/10.4103/2152-7806.120782 .
doi: 10.4103/2152-7806.120782
pubmed: 24340237
pmcid: 3842003
Badhiwala JH, Nassiri F, Witiw CD, Mansouri A, Almenawar SA, da Costa L, et al. Investigating the utility of intraoperative neurophysiological monitoring for anterior cervical discectomy and fusion: analysis of over 140,000 cases from the National (Nationwide) inpatient sample data set. J Neurosurg Spine. 2019;31(1):76–86. https://doi.org/10.3171/2019.1.SPINE181110 .
doi: 10.3171/2019.1.SPINE181110
pubmed: 30925481
Reddy RP, Chang R, Rosario BP, Sudabi S, Anetakis KM, Balzer JR, et al. What is the predictive value of intraoperative somatosensory evoked potential monitoring for postoperative deficit in cervical spine surgery? A meta-analysis. Spine J. 2021;21(4):555–70. https://doi.org/10.1016/j.spinee.2021.01.010 .
doi: 10.1016/j.spinee.2021.01.010
pubmed: 33460808
Traynelis VC, Abode-Iyamah KO, Leick KM, Bender SM, Greenlee JD. Cervical decompression and reconstruction without intraoperative neurophysiological monitoring. J Neurosurg Spine. 2012;16(2):107–13. https://doi.org/10.3171/2011.10.SPINE11199 .
doi: 10.3171/2011.10.SPINE11199
pubmed: 22077472
Gonzalez AA, Shilian P, Hsieh P. Spinal cord mapping. J Clin Neurophysiol. 2013;30(6):604–12. https://doi.org/10.1097/WNP.0000000000000010 .
doi: 10.1097/WNP.0000000000000010
pubmed: 24300985
Ajiboye RM, D’Oro A, Ashana AO, Buerba RA, Lord EL, Buser Z, et al. Routine use of intraoperative neuromonitoring during ACDFs for the treatment of spondylotic myelopathy and radiculopathy is questionable; a review of 15,395 cases. Spine (Phila Pa 1976). 2017;422(1):14–9. https://doi.org/10.1097/BRS.0000000000001662 .
doi: 10.1097/BRS.0000000000001662
Laratta JL, Ha A, Shillingford JN, Makhni MC, Lombardi JM, Thuet E, et al. Neuromonitoring in spinal deformity surgery: a multimodality approach. Glob Spine J. 2018;8(1):68–77. https://doi.org/10.1177/2192568217706970 .
doi: 10.1177/2192568217706970
Koffie RM, Morgan CD, Giraldo JP, Angel S, Walker CT, Godzik J, et al. Should somatosensory and motor evoked potential monitoring be used routinely in all posterior cervical operations for degenerative conditions of the cervical spine? World Neurosurg. 2022;162:e86–90. https://doi.org/10.1016/j.wneu.2022.02.080 .
doi: 10.1016/j.wneu.2022.02.080
pubmed: 35219916
Bose B, Sestokas AK, Schwartz DM. Neurophysiological monitoring of spinal cord function during instrumented anterior cervical fusion. Spine J. 2004;4(2):202–7. https://doi.org/10.1016/j.spinee.2003.06.001 .
doi: 10.1016/j.spinee.2003.06.001
pubmed: 15016399
Mobbs RJ, Rao P, Chandran NK. Anterior cervical discectomy and fusion: analysis of surgical outcome with and without plating. J Clin Neurosci. 2007;14(7):639–42. https://doi.org/10.1016/j.jocn.2006.04.003 .
doi: 10.1016/j.jocn.2006.04.003
pubmed: 17532499
Bebawy JF, Koht A, Mirkovic S. Anterior cervical spine surgery. In: Koht A, Sloan TB, Toleikis JR, editors. Monitoring the nervous system for anesthesiologists and other health care professionals. 2nd ed. Cham: Springer; 2017. p. 473–83.
doi: 10.1007/978-3-319-46542-5_31
Mongan PD, Patel VV. Posterior cervical spine surgery. In: Koht A, Sloan TB, Toleikis JR, editors. Monitoring the nervous system for anesthesiologists and other health care professionals. 2nd ed. Cham: Springer; 2017. p. 485–95.
doi: 10.1007/978-3-319-46542-5_32
Gunnarsson T, Krassioukov AV, Sarjeant R, Fehlings MG. Real-time continuous intraoperative electromyographic and somatosensory evoked potential recordings in spinal surgery: correlation of clinical and electrophysiologic findings in a prospective, consecutive series of 213 cases. Spine (Phila Pa 1976). 2004;29(6):677–84. https://doi.org/10.1097/01.brs.0000115144.30607.e9 .
doi: 10.1097/01.brs.0000115144.30607.e9
pubmed: 15014279
Hassanzadeh H, Nandyala S, Khanna AJ, An HS. Intraoperative neurophysiologic monitoring in adult spine surgery. Semin Spine Surg. 2015;27(4):209–13. https://doi.org/10.1053/j.semss.2015.04.005 .
doi: 10.1053/j.semss.2015.04.005
Wilent WB, Trott JM, Sestokas AK. Roadmap for motor evoked potential (MEP) monitoring for patients undergoing lumbar and lumbosacral spinal fusion procedures. Neurodiagn J. 2021;61(1):27–36. https://doi.org/10.1080/21646821.2021.1866934 .
doi: 10.1080/21646821.2021.1866934
pubmed: 33945448
Manning E, Emerson R. Intraoperative monitoring of scoliosis surgery in young patients. J Clin Neurophysiol. 2024;41(2):138–47. https://doi.org/10.1097/WNP.0000000000001058 .
doi: 10.1097/WNP.0000000000001058
pubmed: 38306222
Gorijala VK, Reddy RP, Anetakis KM, Balzer J, Crammond DJ, Shandal V, et al. Diagnostic utility of different types of somatosensory evoked potential changes in pediatric idiopathic scoliosis correction surgery. Eur Spine J. 2024;33(4):1644–56. https://doi.org/10.1007/s00586-023-08063-y .
doi: 10.1007/s00586-023-08063-y
pubmed: 38285275
Nair MN, Ramakrishna R, Slimp J, Kinney G, Chesnut RM. Left iliac artery injury during anterior lumbar spine surgery diagnosed by intraoperative neurophysiological monitoring. Eur Spine J. 2010(Suppl 2):S203–5. https://doi.org/10.1007/s00586-010-1372-3 .
Melachuri SR, Stopera C, Melachuri MK, Anetakis K, Crammond DJ, Castellano JF, et al. The efficacy of somatosensory evoked potentials in evaluating new neurological deficits after spinal thoracic fusion and decompression. J Neurosurg Spine. 2020;6:1–6. https://doi.org/10.3171/2019.12.SPINE191157 .
doi: 10.3171/2019.12.SPINE191157
Hofler RC, Fessler RG. Intraoperative neuromonitoring and lumbar spinal instrumentation: indications and utility. Neurodiagn J. 2021;61(1):2–10. https://doi.org/10.1080/21646821.2021.1874207 .
doi: 10.1080/21646821.2021.1874207
pubmed: 33945449
Alemo S, Sayadipour A. Role of intraoperative neurophysiologic monitoring in lumbosacral spine fusion and instrumentation: a retrospective study. World Neurosurg. 2010;73(1):72–6. https://doi.org/10.1016/j.surneu.2009.04.024 .
doi: 10.1016/j.surneu.2009.04.024
pubmed: 20452872
Jahangiri FR, Sheryar M, Al OR. Neurophysiological monitoring of the spinal sensory and motor pathways during embolization of spinal arteriovenous malformations—propofol: a safe alternative. Neurodiagn J. 2014;54(2):125–37.
pubmed: 25080772
MacDonald DB, Janusz M. An approach to intraoperative neurophysiologic monitoring of thoracoabdominal aneurysm surgery. J Clin Neurophysiol. 2022;19(1):43–54. https://doi.org/10.1097/00004691-200201000-00006 .
doi: 10.1097/00004691-200201000-00006
Korn A, Halevi D, Lidar Z, Biron T, Ekstein P, Constantini S. Intraoperative neurophysiological monitoring during resection of intradural extramedullary spinal cord tumors: experience with 100 cases. Acta Neurochir (Wien). 2015;157(5):819–30. https://doi.org/10.1007/s00701-014-2307-2 .
doi: 10.1007/s00701-014-2307-2
pubmed: 25514869
Happel L, Kline D. Intraoperative neurophysiology of the peripheral nervous system. In: Deletis V, Shils J, Sala F, Seidel K, editors. Neurophysiology in neurosurgery; a modern approach. 2nd ed. San Diego: Elsevier; 2020. p. 413–29.
doi: 10.1016/B978-0-12-815000-9.00030-7
Schwartz DM, Sestokas AS, Hilibrand AS, Vaccaro AR, Bose B, Li M, et al. Neurophysiological identification of position-induced neurologic injury during anterior cervical spine surgery. J Clin Monit Comput. 2006;20(6):437–44. https://doi.org/10.1007/s10877-006-9032-1 .
doi: 10.1007/s10877-006-9032-1
pubmed: 16960753
Labrom RD, Hoskins M, Reily CW, Tredwell SJ, Wong PK. Clinical usefulness of somatosensory evoked potentials for detection of brachial plexopathy secondary to malpositioning in scoliosis surgery. Spine (Phila Pa 1976). 2005;30(18):2089–93. https://doi.org/10.1097/01.brs.0000179305.89193.46 .
doi: 10.1097/01.brs.0000179305.89193.46
pubmed: 16166901
Shea KG, Apel PJ, Showalter LD, Bell WL. Somatosensory evoked potential monitoring of the brachial plexus during a Woodward procedure for correction of Sprengel’s deformity. Muscle Nerve. 2010;41(2):262–4. https://doi.org/10.1002/mus.21545 .
doi: 10.1002/mus.21545
pubmed: 20082410
Bethune AJ, Houlden DA, Smith TS, Yee AJ, Midha R, Singrakhia M. Generalized peripheral nerve failure during thoracic spine surgery: a case report. J Clin Monit Comput. 2007;21(1):41–7. https://doi.org/10.1007/s10877-006-9056-6 .
doi: 10.1007/s10877-006-9056-6
pubmed: 17120109
Ofiram E, Lonstein JE, Skinner S, Perra JH. The disappearing evoked potentials: a special problem of positioning patients with skeletal dysplasia: case report. Spine (Phila Pa 1976). 2006;31(14):E464-70. https://doi.org/10.1097/01.brs.0000222122.37415.4d .
doi: 10.1097/01.brs.0000222122.37415.4d
pubmed: 16778677
Kamel IR, Drum ET, Kock SA, Whitten JA, Gaughen JP, Barnette RE, et al. The use of somatosensory evoked potentials to determine the relationship between patient positioning and impending upper extremity nerve injury during spine surgery: a retrospective analysis. Anesth Analg. 2006;102(5):1538–42. https://doi.org/10.1213/01.ane.0000198666.11523.d6 .
doi: 10.1213/01.ane.0000198666.11523.d6
pubmed: 16632838
Chung I, Glow JA, Dimopoulos V, Walid MS, Smisson HF, Johnston KW, et al. Upper-limb somatosensory evoked potential monitoring in lumbosacral spine surgery: a prognostic marker for position-related ulnar nerve injury. Spine J. 2009;9(4):287–95. https://doi.org/10.1016/j.spinee.2008.05.004 .
doi: 10.1016/j.spinee.2008.05.004
pubmed: 18684675
Abu-Ata MM, Pasquali C, Sala F. Intraoperative neuromonitoring in tethered cord surgery in children. J Clin Neurophysiol. 2024;41(2):123–33. https://doi.org/10.1097/WNP.0000000000001056 .
doi: 10.1097/WNP.0000000000001056
pubmed: 38306220
Cohen BA, Major MR, Huizenga BA. Pudendal nerve evoked potential monitoring in procedures involving low sacral fixation. Spine (Phila Pa 1976). 1991;16(8 Suppl):S375-8.
pubmed: 1785091
Kline DG. Surgical repair of peripheral nerve injury. Muscle Nerve. 1990;13(9):843–52. https://doi.org/10.1002/mus.880130911 .
doi: 10.1002/mus.880130911
pubmed: 2233871
McGillicuddy JE. Clinical decision making in brachial plexus injuries. Neurosurg Clin N Am. 1991;2(1):137–50.
pubmed: 1821729
doi: 10.1016/S1042-3680(18)30763-0
Lorenzini NA, Schneider JH. Temporary loss of intraoperative motor-evoked potential and permanent loss of somatosensory-evoked potentials associated with a postoperative sensory deficit. J Neurosurg Anesthesiol. 1996;8(2):142–7. https://doi.org/10.1097/00008506-199604000-00008 .
doi: 10.1097/00008506-199604000-00008
pubmed: 8829562
Jahangiri FR, Holmberg A, Vega-Bermudez F, Arlet V. Preventing position-related brachial plexus injury with intraoperative somatosensory evoked potentials and transcranial electrical motor evoked potentials during anterior cervical spine surgery. Am J Electroneurodiagnostic Technol. 2011;51(3):198–205.
pubmed: 21988038
doi: 10.1080/1086508X.2011.11079820
Brown DM, McGinnis WC, Mesghali H. Neurophysiologic intraoperative monitoring during revision total hip arthroplasty. J Bone Jt Surg Am. 2002;84-A(Suppl 2):56–61. https://doi.org/10.2106/00004623-200200002-00007 .
doi: 10.2106/00004623-200200002-00007
Overzet K, Kazewych M, Jahangiri FR. Multimodality intraoperative neurophysiological monitoring (IONM) in anterior hip arthroscopic repair surgeries. Cureus. 2018;10(9): e3346. https://doi.org/10.7759/cureus.3346 .
doi: 10.7759/cureus.3346
pubmed: 30473979
pmcid: 6248867
Sedgwick EM, Katifi HA, Docherty TB, Nicpon K. Dermatomal somatosensory evoked potentials in lumbar disc disease. In: Morocutti C, Rizzo PA, editors. Evoked potentials. Neurophysiological and clinical aspects. New York: Elsevier; 1985. p. 77–88.
Toleikis JR, Skelly JP, Carlvin AO, Toleikis SC, Bernard TN, Burkus JK, et al. The usefulness of electrical stimulation for assessing pedicle screw placements. J Spinal Disord. 2000;13(4):283–9.
pubmed: 10941886
doi: 10.1097/00002517-200008000-00003
Herron LD, Trippi AC, Gonyeau M. Intraoperative use of dermatomal somatosensory-evoked potentials in lumbar stenosis surgery. Spine. 1987;12(4):379–83. https://doi.org/10.1097/00002517-200008000-00003 .
doi: 10.1097/00002517-200008000-00003
pubmed: 3616753
Owen JH, Padberg AM, Spahr-Holland L, Bridwell KH. Clinical correlation between degenerative spine disease and dermatomal somatosensory-evoked potentials in humans. Spine (Phila Pa 1976). 1991;16(6 Suppl):S201-5. https://doi.org/10.1097/00007632-199106001-00005 .
doi: 10.1097/00007632-199106001-00005
pubmed: 1862415
Tsai RY, Yang RS, Nuwer MR, Kanim LE, Delamarter RB, Dawson EG. Intraoperative dermatomal evoked potential monitoring fails to predict outcome from lumbar decompression surgery. Spine (Phila Pa 1976). 1997;22(17):1970–5. https://doi.org/10.1097/00007632-199709010-00005 .
doi: 10.1097/00007632-199709010-00005
pubmed: 9306525
Macdonald DB, Skinner S, Shils JL, Yingling C. Intraoperative motor evoked potential monitoring—a position statement by the American Society of Neurophysiological Monitoring. Clin Neurophysiol. 2013;124(12):2291–316. https://doi.org/10.1016/j.clinph.2013.07.025 .
doi: 10.1016/j.clinph.2013.07.025
pubmed: 24055297
Leppanen RE. Intraoperative monitoring of segmental spinal nerve root function with free-run and electrically-triggered electromyography and spinal cord function with reflexes and F-responses. A position statement by the American Society of Neurophysiological Mon. J Clin Monit Comput. 2005;19(6):437–61. https://doi.org/10.1007/s10877-005-0086-2 .
doi: 10.1007/s10877-005-0086-2
pubmed: 16437295
Sala F, Squintani G, Tramontano V, Arcaro C, Faccioli F, Mazza C. Intraoperative neurophysiology in tethered cord surgery: techniques and results. Childs Nerv Syst. 2013;29(9):1611–24. https://doi.org/10.1007/s00381-013-2188-3 .
doi: 10.1007/s00381-013-2188-3
pubmed: 24013331
Bowman RM, Mohan A, Ito J, Seibly JM, McLone DG. Tethered cord release: a long-term study in 114 patients. J Neurosurg Pediatr. 2009;3(3):181–7. https://doi.org/10.3171/2008.12.peds0874 .
doi: 10.3171/2008.12.peds0874
pubmed: 19338463
Sala F, Tramontano V, Squintani G, Arcaro C, Tot E, Pinna G, et al. Neurophysiology of complex spinal cord untethering. J Clin Neurophysiol. 2014;31(4):326–36. https://doi.org/10.1097/wnp.0000000000000115 .
doi: 10.1097/wnp.0000000000000115
pubmed: 25083844
Kothbauer KF, Novak K. Intraoperative monitoring for tethered cord surgery: an update. Neurosurg Focus. 2004;16(2):E8. https://doi.org/10.3171/foc.2004.16.2.1 .
doi: 10.3171/foc.2004.16.2.1
pubmed: 15209491
Pasquali C, Tramontano V, Sala F. Intraoperative neurophysiological monitoring in tethered cord surgery. In: Deletes V, Shils J, Sala FSK, editors. Neurophysiology in neurosurgery; a modern approach. 2nd ed. San Diego: Elsevier; 2020. p. 365–79.
doi: 10.1016/B978-0-12-815000-9.00027-7
Sonoo M, Shimpo T, Takeda K, Genba K, Nakano I, Mannen T. SEPs in two patients with localized lesions of the postcentral gyrus. Electroencephalogr Clin Neurophysiol. 1991. https://doi.org/10.1016/0168-5597(91)90136-l .
doi: 10.1016/0168-5597(91)90136-l
pubmed: 1720730
Nuwer MR, Aminoff M, Desmedt J, Eisen AA, Goodin D, Matsuoka S, et al. IFCN recommended standards for short latency somatosensory evoked potentials. Report of an IFCN committee. International Federation of Clinical Neurophysiology. Electroencephalogr Clin Neurophysiol. 1994; 91(1): 6–11. https://doi.org/10.1016/0013-4694(94)90012-4
Carter LP, Raudzens PA, Gaines C, Crowell RM. Somatosensory evoked potentials and cortical blood flow during craniotomy for vascular disease. Neurosurgery. 1984;15(1):22–8. https://doi.org/10.1227/00006123-198407000-00006 .
doi: 10.1227/00006123-198407000-00006
pubmed: 6472591
Djurić S, Milenković Z, Klopcić-Spevak M, Spasić M. Somatosensory evoked potential monitoring during intracranial surgery. Acta Neurochir (Wien). 1992;119(1–4):85–90. https://doi.org/10.1007/bf01541787 .
doi: 10.1007/bf01541787
pubmed: 1481759
Friedman WA, Kaplan BL, Day AL, Sypert GW, Curran MT. Evoked potential monitoring during aneurysm operation: observations after fifty cases. Neurosurgery. 1987;20(5):678–87. https://doi.org/10.1227/00006123-198705000-00002 .
doi: 10.1227/00006123-198705000-00002
pubmed: 3601013
Grundy BL, Nelson PB, Lina A, Heros RC. Monitoring of cortical somatosensory evoked potentials to determine the safety of sacrificing the anterior cerebral artery. Neurosurgery. 1982;11(1 Pt 1):64–7. https://doi.org/10.1227/00006123-198207010-00014 .
doi: 10.1227/00006123-198207010-00014
pubmed: 7110571
Jacobs LA, Brinkman SD, Morrell RM, Shirley JG, Ganji S. Long-latency somatosensory evoked potentials during carotid endarterectomy. Am Surg. 1983;49(6):338–44.
pubmed: 6859676
Schramm J. Intraoperative Monitoring with evoked potentials in cerebral vascular surgery and posterior fossa surgery. In: Desmedt J, editor. Neuromonitoring in Surgery. New York: Elsevier; 1989. p. 243–62.
Schramm J, Koht A, Schmidt G, Pechstein U, Taniguchi M, Fahlbusch R. Surgical and electrophysiological observations during clipping of 134 aneurysms with evoked potential monitoring. Neurosurgery. 1990;26(1):61–70. https://doi.org/10.1097/00006123-199001000-00009 .
doi: 10.1097/00006123-199001000-00009
pubmed: 2294480
Anastasian ZH, Ramnath B, Komotar RJ, Bruce JN, Sisti MB, Gallo EJ, et al. Evoked potential monitoring identifies possible neurological injury during positioning for craniotomy. Anesth Analg. 2009;109(3):817–21. https://doi.org/10.1213/ane.0b013e3181b086bd .
doi: 10.1213/ane.0b013e3181b086bd
pubmed: 19690251
pmcid: 3250219
Lopez JR. Neurophysiologic intraoperative monitoring of pediatric cerebrovascular surgery. J Clin Neurophysiol. 2009;26(2):85–94. https://doi.org/10.1097/wnp.0b013e3181a03381 .
doi: 10.1097/wnp.0b013e3181a03381
pubmed: 19279496
Friedell ML, Clark JM, Graham DA, Isley MR, Zhang XF. Cerebral oximetry does not correlate with electroencephalography and somatosensory evoked potentials in determining the need for shunting during carotid endarterectomy. J Vasc Surg. 2008;48(3):601–6. https://doi.org/10.1016/j.jvs.2008.04.065 .
doi: 10.1016/j.jvs.2008.04.065
pubmed: 18639412
Fielmuth S, Uhlig T. The role of somatosensory evoked potentials in detecting cerebral ischemia during carotid endarterectomy. Eur J Anaesthesiol. 2008;25(8):648–56. https://doi.org/10.1017/s0265021508003967 .
doi: 10.1017/s0265021508003967
pubmed: 18371233
Woodworth GF, McGirt MJ, Than KD, Huang J, Perler BA, Tamargo RJ. Selective versus routine intraoperative shunting during carotid endarterectomy; A multivariate outcome analysis. Neurosurgery. 2007;61(6):1170–6; discussion 1176–7. https://doi.org/10.1227/01.neu.0000306094.15270.40 .
Sala F, Beltramello A, Gerosa M. Neuroprotective role of neurophysiological monitoring during endovascular procedures in the brain and spinal cord. Neurophysiol Clin. 2007;37(6):415–21. https://doi.org/10.1016/j.neucli.2007.10.004 .
doi: 10.1016/j.neucli.2007.10.004
pubmed: 18083497
Chang SD, Lopez JR, Steinberg GK. The usefulness of electrophysiological monitoring during resection of central nervous system vascular malformations. J Stroke Cerebrovascular Dis. 1999;8(6):412–22. https://doi.org/10.1016/s1052-3057(99)80049-4 .
doi: 10.1016/s1052-3057(99)80049-4
Stejskal L, Kramár F, Ostrý S, Benes V, Mohapl MLB. Experience of 500 cases of neurophysiological monitoring in carotid endarterectomy. Acta Neurochir (Wien). 2007;149(7):681–8, discussion 689. https://doi.org/10.1007/s00701-007-1228-8 .
Penchet G, Arné P, Cuny E, Moneil P, Loiseau H, Castel JP. Use of intraoperative monitoring of somatosensory evoked potentials to prevent ischaemic stroke after surgical exclusion of middle cerebral artery aneurysms. Acta Neurochir (Wien). 2007;149(4):357–64. https://doi.org/10.1007/s00701-007-1119-z .
doi: 10.1007/s00701-007-1119-z
pubmed: 17380251
Baton O, Szym P, Hoffmann JJ, Borne M, Diraison Y, Baranger B. Cerebral monitoring of somatosensory evoked potentials during carotid surgery: a review of 100 cases. Ann Vasc Surg. 2007;21(1):30–3. https://doi.org/10.1016/j.avsg.2006.10.006 .
doi: 10.1016/j.avsg.2006.10.006
pubmed: 17349332
Stetkárová I, Stejskal L, Kofler M. Tumors localized near the central sulcus may cause increased somatosensory evoked potentials. Clin Neurophysiol. 2006;117(6):1359–66. https://doi.org/10.1016/j.clinph.2006.03.009 .
doi: 10.1016/j.clinph.2006.03.009
pubmed: 16677857
Alsallom F, Simon MV. Pediatric intraoperative neurophysiologic mapping and monitoring in brain surgery. J Clin Neurophysiol. 2024;41(2):96–107. https://doi.org/10.1097/wnp.0000000000001054 .
doi: 10.1097/wnp.0000000000001054
pubmed: 38306217
Florence G, Guerit JM, Gueguen B. Electroencephalography (EEG) and somatosensory evoked potentials (SEP) to prevent cerebral ischaemia in the operating room. Neurophysiol Clin. 2004;34(1):17–32. https://doi.org/10.1016/j.neucli.2004.01.001 .
doi: 10.1016/j.neucli.2004.01.001
pubmed: 15030797
Müller MD, Seidel K, Peschi G, Piechowiak E, Mosimann PJ, Schucht P, et al. Arterial collateral anatomy predicts the risk for intra-operative changes in somatosensory evoked potentials in patients undergoing carotid endarterectomy: a prospective cohort study. Acta Neurochir (Wien). 2021;163(6):1799–805. https://doi.org/10.1007/s00701-020-04624-y .
doi: 10.1007/s00701-020-04624-y
pubmed: 33099692
Park D, Kim BH, Lee SE, Jeong E, Cho K, Park JK, et al. Usefulness of intraoperative neurophysiological monitoring during the clipping of unruptured intracranial aneurysm: diagnostic efficacy and detailed protocol. Front Surg. 2021;8: 631053. https://doi.org/10.3389/fsurg.2021.631053 .
doi: 10.3389/fsurg.2021.631053
pubmed: 33718428
pmcid: 7952634
Weinzierl MR, Reinacher P, Gilsbach JM, Rohde V. Combined motor and somatosensory evoked potentials for intraoperative monitoring: Intra- and postoperative data in a series of 69 operations. Neurosurg Rev. 2007;30(2):109–16; discussion 116. https://doi.org/10.1007/s10143-006-0061-5 .
Yeon JY, Seo DW, Hong SC, Kim JS. Transcranial motor evoked potential monitoring during the surgical clipping of unruptured intracranial aneurysms. J Neurol Sci. 2010;293(1–2):29–34. https://doi.org/10.1016/j.jns.2010.03.013 .
doi: 10.1016/j.jns.2010.03.013
pubmed: 20409559
Schramm J, Watanabe E, Strauss C, Fahlbusch R. Neurophysiologic monitoring in posterior fossa surgery. I. Technical principles, applicability and limitations. Acta Neurochir (Wein). 1989;98(1–2):9–18. https://doi.org/10.1007/bf01407170 .
doi: 10.1007/bf01407170
pubmed: 2741740
Mehta AI, Mohrhaus CA, Hussein AM, Karikari IO, Hughes B, Hodges T, et al. Dorsal column mapping for intramedullary spinal cord tumor resection decreases dorsal column dysfunction. J Spinal Disord Tech. 2012;25(4):205–9. https://doi.org/10.1097/bsd.0b013e318215953f .
doi: 10.1097/bsd.0b013e318215953f
pubmed: 22652988
Pace CJ. Monitoring and mapping of the spinal cord. In: Davis SF, Kaye AD, editors. Principles of neurophysiologic assessment, mapping and monitoring. 2nd ed. Cham: Springer; 2020. p. 195–219.
doi: 10.1007/978-3-030-22400-4_13
Seidel K, Deletis V, Raabe A, Lutz K, Schucht P. Intraoperative neurophysiologic monitoring and mapping during surgery on intramedullary spinal cord tumors in children and adolescents. J Clin Neurophysiol. 2024;41(2):116–22. https://doi.org/10.1097/wnp.0000000000001049 .
doi: 10.1097/wnp.0000000000001049
pubmed: 38306219
Quinones-Hinojosa A, Gulati M, Lyon R, Gupta N, Yingling C. Spinal cord mapping as an adjunct for resection of intramedullary tumors: surgical technique with case illustrations. Neurosurgery. 2002;51(5):1199–206. https://doi.org/10.1097/00006123-200211000-00015 .
doi: 10.1097/00006123-200211000-00015
pubmed: 12383365
Russman SM, Cleary DR, Tchoe Y, Bourhi AM, Stedelin B, Martin J, et al. Constructing 2D maps of human spinal cord activity and isolating the functional midline with high-density microelectrode arrays. Sci Transl Med. 2022;14(664):eabq4744. https://doi.org/10.1126/scitranslmed.abq4744 .
doi: 10.1126/scitranslmed.abq4744
pubmed: 36170445
pmcid: 9650777
Muncie LM, Ellens NR, Tolod-Kemp E, Feler CA, Winestone JS. Intraoperative electrophysiological monitoring for C1–2 spinal cord stimulation. J Neurosurg Spine. 2017;26(2):183–9. https://doi.org/10.3171/2016.7.spine16103 .
doi: 10.3171/2016.7.spine16103
pubmed: 27689422
Choi JG, Ha SW, Son BC. Multimodal, intraoperative monitoring during paddle lead placement for cervicothoracic spinal cord stimulation. Stereotact Funct Neurosurg. 2015;93(4):271–81. https://doi.org/10.1159/000433444 .
doi: 10.1159/000433444
pubmed: 26183282
Le S, Nguyen V, Lee L, Cho SC, Malvestio C, Jones E, et al. Direct brainstem somatosensory evoked potentials for cavernous malformations. J Neurosurg. 2021;5:1–7. https://doi.org/10.3171/2021.7.jns21317 .
doi: 10.3171/2021.7.jns21317
Cheek JC. Posterior fossa intraoperative monitoring. J Clin Neurophysiol. 1993;10(4):412–24. https://doi.org/10.1097/00004691-199310000-00003 .
doi: 10.1097/00004691-199310000-00003
pubmed: 8308140
Singh H, Vogel RW, Lober RM, Doan AT, Matsumoto CI, Tyler JK, et al. Intraoperative neurophysiological monitoring for endoscopic endonasal approaches to the skull base: a technical guide. Scientifica (Cairo). 2016;2016:1751245. https://doi.org/10.1155/2016/1751245 .
doi: 10.1155/2016/1751245
pubmed: 27293965
Slotty PJ, Abdulazim A, Kodama K, Javadi M, Hänggi D, Seifert V, et al. Intraoperative neurophysiological monitoring during resection of infratentorial lesions: the surgeon’s view. J Neurosurg. 2017;126(1):281–8. https://doi.org/10.3171/2015.11.jns15991 .
doi: 10.3171/2015.11.jns15991
pubmed: 26918482
Bejjani GK, Nora PC, Vera PL, Broemling L, Sekhar LN. The predictive value of intraoperative somatosensory evoked potential monitoring: review of 244 procedures. Neurosurgery. 1998;43(3):491–8. https://doi.org/10.1097/00006123-199809000-00050 .
doi: 10.1097/00006123-199809000-00050
pubmed: 9733304
Li F, Deshaies EM, Allott G, Canute G, Gorji R. Direct cortical stimulation but not transcranial electrical stimulation motor evoked potentials detect brain ischemia during brain tumor resection. Am J Electroneurodiagn Technol. 2011;51(3):191–7.
doi: 10.1080/1086508X.2011.11079819
Kodama K, Jayadi M, Seifert V, Szelényi A. Conjunct SEP and MEP monitoring in resection of intratentorial lesions: lessons learned in a cohort of 210 patients. J Neurosurg. 2014;121(6):1453–61. https://doi.org/10.3171/2014.7.jns131821 .
doi: 10.3171/2014.7.jns131821
pubmed: 25216065
Deletis V, Seidel K, Fernández-Conejero I. Intraoperative neurophysiologic monitoring and mapping in children undergoing brainstem surgery. J Clin Neurophysiol. 2024;41(2):108–15. https://doi.org/10.1097/wnp.0000000000001037 .
doi: 10.1097/wnp.0000000000001037
pubmed: 38306218
Sala F, Krsan MJ, Deletis V. Intraoperative neurophysiological monitoring in pediatric neurosurgery: why, when, how? Childs Nerv Syst. 2002;18(6–7):264–87. https://doi.org/10.1007/s00381-002-0582-3 .
doi: 10.1007/s00381-002-0582-3
pubmed: 12172930
Shima F, Morioka T, Tobimatsu S, Kavaklis O, Kato M, Fukui M. Localization of stereotactic targets by microrecording of thalamic somatosensory evoked potentials. Neurosurgery. 1991;28(2):223–9; discussion 229–230. https://doi.org/10.1097/00006123-199102000-00008 .
Suzuki A, Yoshioka K, Nishimura H, Yasui N. Functional localization of sensorimotor cortex by somatosensory evoked potentials produced by femoral nerve stimulation. Neurosurg Focus. 1996;1(3): e3. https://doi.org/10.3171/foc.1996.1.3.7 .
doi: 10.3171/foc.1996.1.3.7
pubmed: 15095991
Neuloh G, Schramm J. Intraoperative neurophysiological mapping and monitoring for supratentorial procedures. In: Deletes V, Shils J, editors. Neurophysiology in neurosurgery, a modern intraoperative approach. New York: Academic Press; 2002. p. 339–401.
doi: 10.1016/B978-012209036-3/50017-2
Allison T, McCarthy G, Luby M, Puce A, Spencer DD. Localization of functional regions of human mesial cortex by somatosensory evoked potential recording and by cortical stimulation. Electroencephalogr Clin Neurophysiol. 1996;100(2):126–40. https://doi.org/10.1016/0013-4694(95)00226-x .
doi: 10.1016/0013-4694(95)00226-x
pubmed: 8617151
Woolsey CN, Erickson TC, Gilson WE. Localization in somatic sensory and motor areas of human cerebral cortex as determined by direct recording of evoked potentials and electrical stimulation. J Neurosurg. 1979;51(4):476–506. https://doi.org/10.3171/jns.1979.51.4.0476 .
doi: 10.3171/jns.1979.51.4.0476
pubmed: 479934
Kombos T, Suess O, Funk T, Kern BC, Brock M. Intra-operative mapping of the motor cortex during surgery in and around the motor cortex. Acta Neurochir (Wien). 2000;142(3):263–8. https://doi.org/10.1007/s007010050034 .
doi: 10.1007/s007010050034
pubmed: 10819256
Sato S, Shibahara I, Inukai M, Komai H, Hide T, Kumabe T. Anatomical and neurophysiological localization of the leg motor area at the medial central sulcus. Clin Neurophysiol. 2022;143:67–74. https://doi.org/10.1016/j.clinph.2022.08.021 .
doi: 10.1016/j.clinph.2022.08.021
pubmed: 36126357
Cedzich C, Taniguchi M, Schäfer S, Schramm J. Somatosensory evoked potential phase reversal and direct motor cortex stimulation during surgery in and around the central region. Neurosurgery. 1996;38(5):962–70. https://doi.org/10.1097/00006123-199605000-00023 .
doi: 10.1097/00006123-199605000-00023
pubmed: 8727822
Simon MV. Intraoperative neurophysiologic sensorimotor mapping and monitoring in supratentorial surgery. J Clin Neurophyiol. 2013;30(6):571–90. https://doi.org/10.1097/01.wnp.0000436897.02502.78 .
doi: 10.1097/01.wnp.0000436897.02502.78
Yildrim S, Appel E, Exeji NA, Jahangiri FR. Chapter 20: Sensory mapping of the brain-median versus tibial nerve. In: Jahangiri F, editor. Introduction to neurophysiology. 1st ed. Dubuque: Kendall-Hunt Publishing; 2022. p. 277–84.
Allison T, McCarthy G, Wood CC, Jones SJ. Potentials evoked in human and monkey cerebral cortex by stimulation of the median nerve. A review of scalp and intracrainal recordings. Brain. 1991;114(6):2465–503. https://doi.org/10.1093/brain/114.6.2465 .
doi: 10.1093/brain/114.6.2465
pubmed: 1782527
Allison T, McCarthy G, Wood CC, Williamson PD, Spencer DD. Human cortical potentials evoked by stimulation of the median nerve. II. Cytoarchitectonic areas generating long latency activity. J Neurophysiol. 1989;62(3):711–22. https://doi.org/10.1152/jn.1989.62.3.711 .
doi: 10.1152/jn.1989.62.3.711
pubmed: 2769355
Arezzo JC, Vaughan HGJ, Legatt AD. Topography and intracranial sources of somatosensory evoked potentials in the monkey. II. Cortical components. Electroencephalogr Clin Neurophysiol. 1981;51(1):1–18. https://doi.org/10.1016/0013-4694(81)91505-4 .
doi: 10.1016/0013-4694(81)91505-4
pubmed: 6161773
Lesser RP, Lüders H, Dinner DS, Hahn J, Morris H, Wyllie E, et al. The source of ‘paradoxical lateralization’ of cortical evoked potentials to posterior tibial nerve stimulation. Neurology. 1987;37(1):82–8. https://doi.org/10.1212/wnl.37.1.82 .
doi: 10.1212/wnl.37.1.82
pubmed: 3796841
Cruse R, Klem G, Lesser RP, Lueders H. Paradoxical lateralization of cortical potentials evoked by stimulation of posterior tibial nerve. Arch Neurol. 1982;39(4):222–5. https://doi.org/10.1001/archneur.1982.00510160028005 .
doi: 10.1001/archneur.1982.00510160028005
pubmed: 7073532
Tsuji S, Murai Y. Variability of initial cortical sensory evoked potentials to posterior tibial nerve stimulation. J UOEH. 1987;9(3):287–98. https://doi.org/10.7888/juoeh.9.287 .
doi: 10.7888/juoeh.9.287
pubmed: 3685713
Seyal M, Emerson RG, Pedley TA. Spinal and early scalp-recorded components of the somatosensory evoked potential following stimulation of the posterior tibial nerve. Electroencephalogr Clin Neurophysiol. 1983;55(3):320–30. https://doi.org/10.1016/0013-4694(83)90210-9 .
doi: 10.1016/0013-4694(83)90210-9
pubmed: 6186464
Giampiccolo D, Parisi C, Tramontano V, Sala F. Chapter 20: Surgery of brain tumors asleep. In: Deletis V, Shils J, Sala F, Seidel K, editors. Neurophysiology in neurosurgery, a modern approach. 2nd ed. Cambridge: Academic Press; 2020. p. 271–82.
doi: 10.1016/B978-0-12-815000-9.00020-4
Lesser RP, Lee HW, Webber WR, Prince B, Crone NE, Miglioretti DL. Short-term variations in response distribution to cortical stimulation. Brain. 2008;131(Pt 6):1528–39. https://doi.org/10.1093/brain/awn044 .
doi: 10.1093/brain/awn044
pubmed: 18337272
pmcid: 2408939
Brown RH, Nash CL, Berilla JA, Amanddio MD. Cortical evoked potential monitoring; A system for intraoperative monitoring of spinal cord function. Spine (Phila Pa 1976). 1984;9(3):256–61.
pubmed: 6729590
doi: 10.1097/00007632-198404000-00006
More RC, Nuwer MR, Dawson EG. Cortical evoked potential monitoring during spinal surgery: sensitivity, specificity, reliability, and criteria for alarm. J Spinal Disord. 1988;1(1):75–80.
pubmed: 2980065
doi: 10.1097/00002517-198801000-00010
Keith RW, Stambough JL, Awender SH. Somatosensory cortical evoked potentials: a review of 100 cases of intraoperative spinal surgery monitoring. J Spinal Disord. 1990;3(3):220–6.
pubmed: 2134432
doi: 10.1097/00002517-199009000-00004
Worth RM, Markand ON, DeRosa GP, Warren CH. Intraoperative somatosensory evoked response monitoring during spinal cord surgery. In: Courjon J, Mauguiere FRM, editors. Clinical applications of evoked potentials in neurology. New York: Raven Press; 1982. p. 367–73.
Brown RH, Nash CL. Current status of spinal cord monitoring. Spine (Phila Pa 1976). 1979;4(6):466–70. https://doi.org/10.1097/00007632-197911000-00003 .
doi: 10.1097/00007632-197911000-00003
pubmed: 515836
Lubicky JP, Spadaro JA, Yuan HA, Fredrickson BE, Henderson N. Variability of somatosensory cortical evoked potential monitoring during spinal surgery. Spine (Phila Pa 1976). 1989;14(8):790–8. https://doi.org/10.1097/00007632-198908000-00003 .
doi: 10.1097/00007632-198908000-00003
pubmed: 2781392
Taylor AJ, Combs K, Kay RD, Bryman J, Tye EY, Rolfe K. Combined motor and sensory intraoperative neuromonitoring for cervical spondylotic myelopathy surgery causes confusion: a level-1 diagnostic study. Spine (Phila Pa 1976). 2021;46(22):E1185-91. https://doi.org/10.1097/brs.0000000000004070 .
doi: 10.1097/brs.0000000000004070
pubmed: 34417419
Lee J, Hilibrand AS, Lim MR, Zavatsky J, Zeiller S, Schwartz DM, et al. Characterization of neurophysiologic alerts during anterior cervical spine surgery. Spine (Phila Pa 1976). 2006;31(17):1916–22. https://doi.org/10.1097/01.brs.0000228724.01795.a2 .
doi: 10.1097/01.brs.0000228724.01795.a2
pubmed: 16924208
Hilibrand AS, Schwartz DM, Sethuraman V, Vaccaro AR, Albert TJ. Comparison of transcranial electric motor and somatosensory evoked potential monitoring during cervical spine surgery. J Bone Jt Surg Am. 2004;86(6):1248–53. https://doi.org/10.2106/00004623-200406000-00018 .
doi: 10.2106/00004623-200406000-00018
Holdefer R, MacDonald D, Skinner S. Somatosensory and motor evoked potentials as biomarkers for post-operative neurological status. Clin Neurophysiol. 2015;126(5):857–65. https://doi.org/10.1016/j.clinph.2014.11.009 .
doi: 10.1016/j.clinph.2014.11.009
pubmed: 25499613
Grundy BL. Monitoring of sensory evoked potentials during neurosurgical operations: methods and applications. Neurosurgery. 1982;11(4):556–75.
pubmed: 6755296
doi: 10.1097/00006123-198210000-00020
Skinner S, Holdefer R. Intraoperative neuromonitoring alerts that reverse with intervention: treatment paradox and what to do about it. J Clin Neurophysiol. 2014;31(2):118–26. https://doi.org/10.1097/wnp.0000000000000030 .
doi: 10.1097/wnp.0000000000000030
pubmed: 24691228
Isley MR, Edmonds HLJ, Stecker M. Guidelines for intraoperative neuromonitoring using raw (analog or digital waveforms) and quantitative electroencephalography: a position statement by the American Society of Neurophysiological Monitoring. J Clin Monit Comput. 2009;23(6):369–90. https://doi.org/10.1007/s10877-009-9191-y .
doi: 10.1007/s10877-009-9191-y
pubmed: 19757102
American Clinical Neurophysiology Society. Guideline 11A: Recommended standards for neurophysiologic intraoperative monitoring—principles. American Clinical Neurophysiology Society. 2009. https://www.acns.org/pdf/guidelines/Guideline-11A.pdf . Accessed 29 Apr 2024
Stecker MM, Patterson T, Netherton BL. Mechanisms of electrode induced injury. Part 1: theory. Am J Electroneurodiagnostic Technol. 2006;46(4):315–42.
pubmed: 17285816
doi: 10.1080/1086508X.2006.11079592
Patterson T, Stecker MM, Netherton BL. Mechanisms of electrode induced injury. Part 2: clinical experience. Am J Electroneurodiagnostic Technol. 2007;47(2):93–113.
pubmed: 17679578
doi: 10.1080/1086508X.2007.11079617
Netherton BL, Stecker MM, Patterson T. Mechanisms of electrode induced injury. Part 3: practical concepts and avoidance. Am J Electroneurodiagnostic Technol. 2007;47(4):257–63.
pubmed: 18271314
doi: 10.1080/1086508X.2007.11079641
International Organization of Societies for Electrophysiological Technology (OSET). Guidelines for performing EEG and evoked potential monitoring during surgery. Am J END Technol. 1999;39(4):257–77.
CMS-Medicare. Medical record maintenance & access requirements. https://www.cms.gov/files/document/mln4840534-medical-record-maintenance-and-access-requirements.pdf . Accessed 23 Oct 2023.
Isley MR, Pearlman RC. Credentialing and competency policy statement for intraoperative neuromonitoring staff: American Society of Neurophysiological Monitoring position statement. Synergy. 2006;34:38–41.
Skinner SA, Cohen BA, Morledge DE, McAuliffe JJ, Hastings JD, Yingling CD, et al. Practice guidelines for the supervising professional: Intraoperative neurophysiological monitoring. J Clin Monit Comput. 2014;28(2):103–11. https://doi.org/10.1007/s10877-013-9496-8 .
doi: 10.1007/s10877-013-9496-8
pubmed: 24022172
Gertsch JH, Moreira JJ, Lee GR, Hastings JD, Ritzl E, Eccher MA, et al. Practice guidelines for the supervising professional: intraoperative neurophysiological monitoring. J Clin Monit Compu. 2019;33(2):175–83. https://doi.org/10.1007/s10877-018-0201-9 .
doi: 10.1007/s10877-018-0201-9
ASET - The Neurodiagnostic Society. 2022. https://www.aset.org/wp-content/uploads/2022/01/IONM_National_Competency_Skill_Standards_Approved_2011.pdf . Accessed 21 Mar 2024
López JR, Ahn-Ewing J, Emerson R, Ford C, Gale C, Gertsch JH, et al. Guidelines for qualifications of neurodiagnostic personnel: a joint position statement of the American Clinical Neurophysiology Society, American Association of Neuromuscular & Electrodiagnostic Medicine, and American Society of Neurophysiological Monitoring, and ASET—The Neurodiagnostic Society. J Clin Neurophysiol. 2023;40(4):271–85. https://doi.org/10.1097/wnp.0000000000001004 .
doi: 10.1097/wnp.0000000000001004
pubmed: 36962008
pmcid: 10150627
American Audiology Board of Intraoperative Monitoring. What is the value of specialty board certification in IOM for an audiologist? https://www.aabiom.com/ . Accessed 2024 Jan 29.
ABRET Neurodiagnostic Credentialing and Accreditation. (2022) https://abret.org/ . Accessed 2024 Apr 24.
Morledge DE, Stecker M. The American Society of Neurophysiological Monitoring position statements project. J Clin Monit Comput. 2006;20(1):43–6. https://doi.org/10.1007/s10877-005-9000-1 .
doi: 10.1007/s10877-005-9000-1
pubmed: 16523230