iStent insertion orientation and impact on trabecular meshwork motion resolved by optical coherence tomography imaging.


Journal

Journal of biomedical optics
ISSN: 1560-2281
Titre abrégé: J Biomed Opt
Pays: United States
ID NLM: 9605853

Informations de publication

Date de publication:
Jul 2024
Historique:
received: 29 04 2024
revised: 02 07 2024
accepted: 03 07 2024
medline: 29 7 2024
pubmed: 29 7 2024
entrez: 29 7 2024
Statut: ppublish

Résumé

The iStent is a popular device designed for glaucoma treatment, functioning by creating an artificial fluid pathway in the trabecular meshwork (TM) to drain aqueous humor. The assessment of iStent implantation surgery is clinically important. However, current tools offer limited information. We aim to develop innovative assessment strategies for iStent implantation using optical coherence tomography (OCT) to evaluate the position and orientation of the iStent and its biomechanical impact on outflow system dynamics. We examined four iStents in the two eyes of a glaucoma patient. Three-dimensional (3D) OCT structural imaging was conducted for each iStent, and a semi-automated algorithm was developed for iStent segmentation and visualization, allowing precise measurement of position and orientation. In addition, phase-sensitive OCT (PhS-OCT) imaging was introduced to measure the biomechanical impact of the iStent on the outflow system quantified by cumulative displacement (CDisp) of pulse-dependent trabecular TM motion. The 3D structural image processed by our algorithm definitively resolved the position and orientation of the iStent in the anterior segment, revealing substantial variations in relevant parameters. PhS-OCT imaging demonstrated significantly higher CDisp in the regions between two iStents compared to locations distant from the iStents in both OD ( Our proposed structural imaging technique improved the characterization of the iStent's placement. The imaging results revealed inherent challenges in achieving precise control of iStent insertion. Furthermore, PhS-OCT imaging unveiled potential biomechanical alterations induced by the iStent. This unique methodology shows potential as a valuable clinical tool for evaluating iStent implantation.

Identifiants

pubmed: 39070082
doi: 10.1117/1.JBO.29.7.076008
pii: 240120GR
pmc: PMC11283271
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

076008

Informations de copyright

© 2024 The Authors.

Auteurs

Zhaoyu Gong (Z)

University of Washington, Department of Bioengineering, Seattle, Washington, United States.

Murray A Johnstone (MA)

University of Washington, Department of Ophthalmology, Seattle, Washington, United States.

Ruikang K Wang (RK)

University of Washington, Department of Bioengineering, Seattle, Washington, United States.
University of Washington, Department of Ophthalmology, Seattle, Washington, United States.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH