Comparison of lung volumes measured with computed tomography and whole-body plethysmography - a systematic review.

Systematic review body box computed tomography functional residual capacity residual volume static lung volumes total lung capacity whole-body plethysmography

Journal

European clinical respiratory journal
ISSN: 2001-8525
Titre abrégé: Eur Clin Respir J
Pays: United States
ID NLM: 101662134

Informations de publication

Date de publication:
2024
Historique:
medline: 31 7 2024
pubmed: 31 7 2024
entrez: 31 7 2024
Statut: epublish

Résumé

Whole-body plethysmography is the preferred method for measuring the static lung volumes: total lung capacity (TLC), functional residual capacity (FRC) and residual volume (RV), as it also incorporates trapped gas - a common finding in chronic obstructive pulmonary disease (COPD). Quantitative computed tomography (CT) is a promising alternative to plethysmography, which can be challenging to perform for patients with severely impaired lung function. The present systematic review explores the agreement between lung volumes measured by plethysmography and CT, as well as the attempts being made to optimize alignment between these two methods. A literature search was performed on the PubMed database using the block search strategy. Articles were included if they provided both CT based and plethysmography based TLC. Risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) checklist. 22 articles were included. On average, CT-derived TLC (CT-TLC) was 709 mL lower compared to plethysmography TLC (p-TLC) with a 12.1% deviation from the reference standard, p-TLC. This discrepancy (ΔTLC) appeared slightly larger in obstructive patients (obstructive: 781 mL, non-obstructive: 609 mL), whereas percent deviation was slightly smaller (obstructive: 11.4%, non-obstructive: 13.5%). CT-based RV analyses primarily based on COPD patients measured 603 mL higher than plethysmography (p-RV) with 17.8% deviation from p-RV. Studies utilizing spirometry-gating for CT acquisition reported good agreement between modalities (ΔTLC: 70-280 mL), and one study demonstrated noticeable improvements compared to conventional breath-hold instructions in an otherwise identical study setting. CT quantifications routinely underestimate TLC and overestimate RV in comparison to plethysmography. Spirometry gating reduces the level of disagreement and can be of assistance when patients are already undergoing CT. However, further studies are needed to confirm these results.

Identifiants

pubmed: 39081799
doi: 10.1080/20018525.2024.2381898
pii: 2381898
pmc: PMC11288198
doi:

Types de publication

Journal Article Review

Langues

eng

Pagination

2381898

Informations de copyright

© 2024 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.

Déclaration de conflit d'intérêts

No potential conflict of interest was reported by the author(s).

Auteurs

Høgni Janus Bjarnason Olsen (HJB)

Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.

Jann Mortensen (J)

Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
Department of Medicine, The National Hospital, Torshavn, Faroe Islands.

Classifications MeSH