Apixaban plasma concentrations before and after catheter ablation for atrial fibrillation.
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2024
2024
Historique:
received:
02
03
2024
accepted:
15
07
2024
medline:
31
7
2024
pubmed:
31
7
2024
entrez:
31
7
2024
Statut:
epublish
Résumé
Catheter ablation in patients with atrial fibrillation is associated with a transient increase in thromboembolic risk and adequate anticoagulation is highly important. When patients are anticoagulated with apixaban, monitoring of plasma concentrations of the drug is not routinely performed. This study aimed to assess the influence of clinical patient characteristics, concomitant drug treatment and self-reported adherence on apixaban concentrations, and to describe the intra- and inter-individual variability in apixaban concentrations in this group of patients. Method Apixaban concentrations from 141 patients were measured in plasma one week before ablation and two, six and ten weeks after ablation, employing ultra-high performance liquid chromatography coupled with tandem mass spectrometry. In samples not obtained at trough, apixaban concentrations were adjusted to trough levels. Self-reported adherence was registered by means of the 8-item Morisky Medication Adherence Scale before and after ablation. There were statistically significant, positive correlations between apixaban concentrations and increased age, female sex, lower glomerular filtration rate, higher CHA2DS2-VASc score, use of cytochrome P450 3A4 and/or p-glycoprotein inhibitors, and use of amiodarone. Self-reported adherence was generally high. The mean intra-individual and inter-individual coefficients of variation were 29% and 49%, respectively. In patients undergoing catheter ablation for atrial fibrillation, age, sex, renal function, interacting drugs and cerebrovascular risk profile were all associated with altered plasma apixaban concentration. In this group of patients with a generally high self-reported adherence, intra-individual variability was modest, but the inter-individual variability was substantial, and similar to those previously reported in other patient apixaban-treated populations. If a therapeutic concentration range is established, there might be a need for a more flexible approach to apixaban dosing, guided by therapeutic drug monitoring.
Sections du résumé
BACKGROUND
BACKGROUND
Catheter ablation in patients with atrial fibrillation is associated with a transient increase in thromboembolic risk and adequate anticoagulation is highly important. When patients are anticoagulated with apixaban, monitoring of plasma concentrations of the drug is not routinely performed. This study aimed to assess the influence of clinical patient characteristics, concomitant drug treatment and self-reported adherence on apixaban concentrations, and to describe the intra- and inter-individual variability in apixaban concentrations in this group of patients. Method Apixaban concentrations from 141 patients were measured in plasma one week before ablation and two, six and ten weeks after ablation, employing ultra-high performance liquid chromatography coupled with tandem mass spectrometry. In samples not obtained at trough, apixaban concentrations were adjusted to trough levels. Self-reported adherence was registered by means of the 8-item Morisky Medication Adherence Scale before and after ablation.
RESULTS
RESULTS
There were statistically significant, positive correlations between apixaban concentrations and increased age, female sex, lower glomerular filtration rate, higher CHA2DS2-VASc score, use of cytochrome P450 3A4 and/or p-glycoprotein inhibitors, and use of amiodarone. Self-reported adherence was generally high. The mean intra-individual and inter-individual coefficients of variation were 29% and 49%, respectively.
CONCLUSION
CONCLUSIONS
In patients undergoing catheter ablation for atrial fibrillation, age, sex, renal function, interacting drugs and cerebrovascular risk profile were all associated with altered plasma apixaban concentration. In this group of patients with a generally high self-reported adherence, intra-individual variability was modest, but the inter-individual variability was substantial, and similar to those previously reported in other patient apixaban-treated populations. If a therapeutic concentration range is established, there might be a need for a more flexible approach to apixaban dosing, guided by therapeutic drug monitoring.
Identifiants
pubmed: 39083480
doi: 10.1371/journal.pone.0308022
pii: PONE-D-24-06695
doi:
Substances chimiques
Pyridones
0
apixaban
3Z9Y7UWC1J
Pyrazoles
0
Factor Xa Inhibitors
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0308022Informations de copyright
Copyright: © 2024 Aakerøy et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Déclaration de conflit d'intérêts
The authors have declared that no competing interests exist.