Endovascular treatment of aneurysm remnants with the Contour Neurovascular System after previous treatment.
Feasibility
aneurysm occlusion
endovascular
intracranial aneurysm
wide-necked
Journal
Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences
ISSN: 2385-2011
Titre abrégé: Interv Neuroradiol
Pays: United States
ID NLM: 9602695
Informations de publication
Date de publication:
01 Aug 2024
01 Aug 2024
Historique:
medline:
2
8
2024
pubmed:
2
8
2024
entrez:
2
8
2024
Statut:
aheadofprint
Résumé
The Contour Neurovascular System (CNS) is a novel intrasaccular flow disrupting device with a semi-3D cup-like shape for the treatment of intracranial aneurysms. This study investigates the potential and limitations of the CNS for embolization of aneurysm remnants after previous treatment. Ten cases of aneurysm recurrence treatment with the CNS were analyzed from a single-center database. Technical success, procedural aspects, complications, and angiographic results were evaluated. The aneurysms (median width: 5.3 mm, median neck width: 3.8 mm) were located in the anterior communicating artery (4), basilar tip (3), internal carotid artery (1), middle cerebral artery (1), and superior cerebellar artery (1). The aneurysms were initially treated endovascularly (9) and by clipping (1). Retreatment failed in one case where the smallest available CNS proved to be too small and had to be removed. Adjunctive coiling was performed in two large remnants of partially thrombosed basilar tip aneurysms. There were no procedural complications or morbidity. At a median follow-up of nine months, 4/8 (50%) aneurysms were completely occluded, 2/8 (25%) had neck remnants, and 2/8 (25%) had aneurysm remnants. The two aneurysm remnants were retreated with coiling and stent-assisted coiling, respectively. CNS treatment of aneurysm remnants may be feasible, especially for shallow, wide-necked aneurysm geometries. Further studies are needed to identify aneurysm subsets that benefit from CNS retreatment and to define mid- and long-term occlusion rates.
Identifiants
pubmed: 39091055
doi: 10.1177/15910199241264871
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
15910199241264871Déclaration de conflit d'intérêts
Declaration of conflicting interestsThe authors declared the following potential conflicts of interest with respect to the research, authorship, and/or publication of this article: CK serves as consultant for Acandis GmbH (Pforzheim, Germany) and as proctor for MicroVention Inc./Sequent Medical (Aliso Viejo, CA, USA). TL serves or previously served as proctor for MicroVention Inc./Sequent Medical (Aliso Viejo, CA, USA), CERUS Endovascular (Fremont, CA, USA), Phenox (Bochum, Germany), Stryker (Kalamazoo, MI, USA), and Medtronic (Dublin, Ireland). The other authors declare that they have no competing interests.