Green highly sensitive and selective spectroscopic detection of guaifenesin in multiple dosage forms and spiked human plasma.
Chemometry
Green metric tools
Guaifenesin
Spectrofluorimetry
Spiked human plasma
Journal
Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288
Informations de publication
Date de publication:
12 Aug 2024
12 Aug 2024
Historique:
received:
05
03
2024
accepted:
26
07
2024
medline:
13
8
2024
pubmed:
13
8
2024
entrez:
12
8
2024
Statut:
epublish
Résumé
Guaifenesin (GUA) is determined in dosage forms and plasma using two methods. The spectrofluorimetric technique relies on the measurement of native fluorescence intensity at 302 nm upon excitation wavelength "223 nm". The method was validated according to ICH and FDA guidelines. A concentration range of 0.1-1.1 μg/mL was used, with limit of detection (LOD) and quantification (LOQ) values 0.03 and 0.08 µg/mL, respectively. This method was used to measure GUA in tablets and plasma, with %recovery of 100.44% ± 0.037 and 101.03% ± 0.751. Furthermore, multivariate chemometric-assisted spectrophotometric methods are used for the determination of GUA, paracetamol (PARA), oxomemazine (OXO), and sodium benzoate (SB) in their lab mixtures. The concentration ranges of 2.0-10.0, 4.0-16.0, 2.0-10.0, and 3.0-10.0 µg/mL for OXO, GUA, PARA, and SB; respectively, were used. LOD and LOQ were 0.33, 0.68, 0.28, and 0.29 µg/mL, and 1.00, 2.06, 0.84, and 0.87 µg/mL for PARA, GUA, OXO, and SB. For the suppository application, the partial least square (PLS) model was used with %recovery 98.49% ± 0.5, 98.51% ± 0.64, 100.21% ± 0.36 & 98.13% ± 0.51, although the multivariate curve resolution alternating least-squares (MCR-ALS) model was used with %recovery 101.39 ± 0.45, 99.19 ± 0.2, 100.24 ± 0.12, and 98.61 ± 0.32 for OXO, GUA, PARA, and SB. Analytical Eco-scale and Analytical Greenness Assessment were used to assess the greenness level of our techniques.
Identifiants
pubmed: 39134599
doi: 10.1038/s41598-024-68711-1
pii: 10.1038/s41598-024-68711-1
doi:
Substances chimiques
Guaifenesin
495W7451VQ
Tablets
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
18694Informations de copyright
© 2024. The Author(s).
Références
Guaifenesin @ Pubchem.Ncbi.Nlm.Nih.Gov.
Albrecht, H. H., Dicpinigaitis, P. V. & Guenin, E. P. Role of guaifenesin in the management of chronic bronchitis and upper respiratory tract infections. Multidiscipl. Respir. Med. 12, 1–11 (2017).
Dicpinigaitis, P. V. & Gayle, Y. E. Effect of guaifenesin on cough reflex sensitivity. Chest 124, 2178–2181 (2003).
pubmed: 14665498
doi: 10.1378/chest.124.6.2178
Ohar, J. A., Donohue, J. F. & Spangenthal, S. The role of guaifenesin in the management of chronic mucus hypersecretion associated with stable chronic bronchitis: A comprehensive review. Chronic obstruct. Pulm. Dis. (Miami, Fla). 6, 341–349 (2019).
doi: 10.15326/jcopdf.6.4.2019.0139
Deshpande, S. S. Principles and applications of luminescence spectroscopy. Crit. Rev. Food Sci. Nutr. 41, 155–224 (2001).
pubmed: 11310779
doi: 10.1080/20014091091797
Karwasara, V., Nahata, A. & Dixit, V. A simple, rapid and sensitive spectrofluorimetric method for the determination of camptothecin. Orient. Pharm. Exp. Med. 12, 151–156 (2012).
doi: 10.1007/s13596-011-0053-z
Sharaf, M. & Stiff, D. Determination of guaifenesin in human serum by capillary gas chromatography and electron capture detection. J. Pharm. Biomed. Anal. 35, 801–806 (2004).
pubmed: 15193724
doi: 10.1016/j.jpba.2004.01.028
Harsono, T., Yuwono, M. & Indrayanto, G. Simultaneous determination of some active ingredients in cough and cold preparations by gas chromatography, and method validation. J. AOAC Int. 88, 1093–1098 (2005).
pubmed: 16152925
doi: 10.1093/jaoac/88.4.1093
Hamid, S. et al. GC–MS study of thermochemical conversion of guaifenesin in the presence of 1-butyl-3-methylimidazolium-based ionic liquids. Res. Chem. Intermed. 43, 4007–4021 (2017).
doi: 10.1007/s11164-016-2858-3
Héberger, K. Chapter 7—Chemoinformatics—Multivariate Mathematical–Statistical Methods for Data Evaluation 141–169 (Elsevier, 2008).
Frost, T. Quantitative Analysis 811–815 (Academic Press, 2018).
Eriksson, L., Johansson, E. & Trygg, J. An Introduction to Some Basic Chemometric Tools 69–88 (Wiley, 2021).
Tantawy, M., Yehia, A. & Aboul-Enein, H. Simultaneous determination of guaifenesin enantiomers and ambroxol HCl using 50-mm chiral column for a negligible environmental impact. Chirality 31, 835–844 (2019).
pubmed: 31368587
doi: 10.1002/chir.23116
Itagimatha, N. & Manjunatha, D. H. RP-HPLC-UV method development and validation for simultaneous determination of terbutaline sulphate, ambroxol HCl and guaifenesin in pure and dosage forms. Ann. Pharm. Françaises 77, 295–301 (2019).
doi: 10.1016/j.pharma.2019.02.004
El-Kimary, E. et al. Robust chromatographic methods for the analysis of two quaternary mixtures containing paracetamol, codeine, guaifenesin and pseudoephedrine or phenylephrine in their dosage forms. J. Chromatogr. Sci. 57, 828–837 (2019).
pubmed: 31504290
doi: 10.1093/chromsci/bmz057
Hayun, Y. H. Development of a high performance liquid chromatography method for simultaneous analysis of theophylline, guaifenesin and diphenhydramine in an elixir. Trop. J. Pharm. Res. 16, 2501–2506 (2017).
doi: 10.4314/tjpr.v16i10.25
Njaria, P. et al. A versatile HPLC method for the simultaneous determination of bromhexine, guaifenesin, ambroxol, salbutamol/terbutaline, pseudoephedrine, triprolidine, and chlorpheniramine maleate in cough-cold syrups. Chromatographia 79, 1507–1514 (2016).
doi: 10.1007/s10337-016-3158-1
Imamoglu, E. & Kucuk Tunca, A. Simultaneous determination of guaifenesin and ephedrine HCl binary mixture in syrup dosage forms and human plasma by using rp-hplc-dad. J. Liq. Chromatogr. Relat. Technol. 37, 1039–1051 (2014).
doi: 10.1080/10826076.2013.765459
Farid, N. F. et al. Simultaneous determination of a quaternary mixture of oxomemazine, sodium benzoate, guaifenesin and paracetamol by chromatographic methods. Beni-Suef Univ. J. Basic Appl. Sci. 3, 260–268 (2014).
Maithani, M. et al. Development and validation of a novel RP-HPLC method for simultaneous determination of salbutamol sulfate, guaifenesin, and ambroxol hydrochloride in tablet formulation. J. Liq. Chromatogr. Relat. Technol. 35, 1156–1170 (2012).
doi: 10.1080/10826076.2011.615289
Dubey, N., Sahu, S. & Singh, G. N. Development of HPLC method for simultaneous estimation of ambroxol, guaifenesin and salbutamol in single dose form. Indian J. Chem. Sect. B Org. Med. Chem. 51, 1633–1636 (2012).
Reddy, S. P. et al. Development and validation of stability indicating the RP-HPLC method for the estimation of related compounds of guaifenesin in pharmaceutical dosage forms. Pharm. Methods 2, 229–234 (2011).
pubmed: 23781462
pmcid: 3658082
doi: 10.4103/2229-4708.93391
Dönmez, Ö. A. et al. Simultaneous determination of potassium guaiacolsulfonate, guaifenesin, diphenhydramine HCl and carbetapentane citrate in syrups by using HPLC-DAD coupled with partial least squares multivariate calibration. Talanta 83, 1601–1605 (2011).
pubmed: 21238758
doi: 10.1016/j.talanta.2010.11.054
Abdelkawy, M., Metwally, F. & Raghy, N. Simultaneous determination of ambroxol hydrochloride and guaifenesin by HPLC, TLC-spectrodensitometric and multivariate calibration methods in pure form and in cough cold formulations. J. Chromatogr. Sep. Tech. 02, 2–9 (2011).
doi: 10.4172/2157-7064.1000112
Kulikov, A. & Verushkin, A. Simultaneous determination of paracetamol, caffeine, guaifenesin and preservatives in syrups by Micellar LC. Chromatographia 67, 347–355 (2008).
doi: 10.1365/s10337-007-0510-5
Grosa, G. et al. Simultaneous, stability indicating, HPLC-DAD determination of guaifenesin and methyl and propyl-parabens in cough syrup. J. Pharm. Biomed. Anal. 41, 798–803 (2006).
pubmed: 16497471
doi: 10.1016/j.jpba.2006.01.026
Ansari Dogaheh, M., Kazemipour, M. & Shahriar, M. Simultaneous quantitation of theophylline and guaifenesin in syrup by HPLC, derivative and derivative ratio spectrophotometry for quality control purposes. Iran. J. Pharmacol. Ther. 5, 67–72 (2006).
Galli, V. & Barbas, C. High-performance liquid chromatographic analysis of dextromethorphan, guaifenesin and benzoate in a cough syrup for stability testing. J. Chromatogr. A 1048, 207–211 (2004).
pubmed: 15481258
doi: 10.1016/S0021-9673(04)01210-5
Wilcox, M. L. & Stewart, J. T. HPLC determination of guaifenesin with selected medications on underivatized silica with an aqueous-organic mobile phase. J. Pharm. Biomed. Anal. 23, 909–916 (2000).
pubmed: 11022915
doi: 10.1016/S0731-7085(00)00359-9
Buleandră, M. et al. Facile electrochemical sensor for sensitive and selective determination of guaifenesin, phenylephrine and paracetamol on electrochemically pretreated pencil graphite electrode. Micromachines 13, 1213 (2022).
pubmed: 36014134
pmcid: 9414709
doi: 10.3390/mi13081213
Işık, H. et al. Electroanalytical analysis of guaifenesin on poly(acridine orange) modified glassy carbon electrode and its determination in pharmaceuticals and serum samples. Comb. Chem. High Throughput Screen. 24, 376–385 (2021).
pubmed: 32646355
doi: 10.2174/1386207323666200709170450
Dehnavi, A. & Soleymanpour, A. Silver nanoparticles/poly(L-cysteine) nanocomposite modified pencil graphite for selective electrochemical measurement of guaifenesin in real samples. Measurement 175, 109103 (2021).
doi: 10.1016/j.measurement.2021.109103
Hatamvand, R., Adeli, M. & Yari, A. Synthesis of glycerol-thiophene nanoparticles, a suitable sensing platform for voltammetric determination of guaifenesin. J. Polym. Sci. 58, 2784–2791 (2020).
doi: 10.1002/pol.20200446
Ağın, F. Voltammetric determination of guaifenesin in pharmaceuticals and urine samples based on poly(bromocresol purple) modified glassy carbon electrode. Curr. Pharm. Anal. 16, 633–639 (2020).
doi: 10.2174/1573412915666190114154434
Hendawy, H. et al. Voltammetric method for simultaneous determination of ascorbic acid, paracetamol and guaifenesin using a sequential experimentation strategy. Microchem. J. 145, 428–434 (2018).
doi: 10.1016/j.microc.2018.11.010
Kalambate, P. K., Rawool, C. R. & Srivastava, A. K. Fabrication of graphene nanosheet–multiwalled carbon nanotube–polyaniline modified carbon paste electrode for the simultaneous electrochemical determination of terbutaline sulphate and guaifenesin. New J. Chem. 41, 7061–7072 (2017).
doi: 10.1039/C7NJ00101K
Jos, T. et al. Voltammetric determination of guaifenesin on a MWCNT modified Pt electrode. ECS Electrochem. Lett. 3, B23 (2014).
doi: 10.1149/2.0021412eel
Tapsoba, I., Belgaied, J. E. & Boujlel, K. Voltammetric assay of guaifenesin in pharmaceutical formulation. J. Pharm. Biomed. Anal. 38, 162–165 (2005).
pubmed: 15907635
doi: 10.1016/j.jpba.2004.11.056
Roshdy, A. et al. Fast concurrent determination of guaifenesin and pholcodine in formulations and spiked plasma using first derivative synchronous spectrofluorimetric approach. Luminescence 39, e4660 (2024).
pubmed: 38286595
doi: 10.1002/bio.4660
Elawadi, G. G. et al. Two green and sensitive spectrofluorimetric approaches for determination of Ambroxol and guaifenesin in their single and combined pharmaceutical formulations. Luminescence 39, e4711 (2024).
pubmed: 38501299
doi: 10.1002/bio.4711
Chanchala, M. et al. Development and validation of UV spectroscopic method for estimation of lamivudine in tablet dosage form. Int. J. Pharm. Sci. Med. 8, 73–79 (2023).
Ebrahimi, M. et al. Rapid simultaneous spectrophotometric determination of acetaminophen, phenylephrine, and guaifenesin in a cold syrup formulation based on continuous wavelet transform and first derivative transform methods. Optik 230, 166323–166323 (2021).
doi: 10.1016/j.ijleo.2021.166323
Maher, H. M., Alshehri, M. M. & Al-taweel, S. M. Derivative emission spectrofluorimetry for the simultaneous determination of guaifenesin and phenylephrine hydrochloride in pharmaceutical tablets. Luminescence 30, 330–336 (2015).
pubmed: 25044215
doi: 10.1002/bio.2735
Lamedara, R., Raj, H. & Jain, V. Development and validation of analytical method for bromhexine hydrochloride, chlorpheniramine maleate and guaifenesin by simultaneous equation spectroscopic method. Asian J. Res. Pharm. Sci. 5, 76–82 (2015).
Abdallah, O. M. Sensitive spectrophotometric method for quantitation of guaifenesin and dropropizine in their dosage forms. Int. J. Anal. Chem. 2010, 1–5 (2010).
doi: 10.1155/2010/704564
Branch, S. K. Guidelines from the international conference on harmonisation (ICH). J. Pharm. Biomed. Anal. 38, 798–805 (2005).
pubmed: 16076542
doi: 10.1016/j.jpba.2005.02.037
<FDA bioanalytical validation 2018.pdf>.
Brereton, R. G. Multilevel multifactor designs for multivariate calibration. Analyst 122, 1521–1529 (1997).
doi: 10.1039/a703654j
Yehia, A. M. et al. Chemometrics for resolving spectral data of cephalosporines and tracing their residue in waste water samples. Spectrochim. Acta A Mol. Biomol. Spectrosc. 219, 436–443 (2019).
pubmed: 31063958
doi: 10.1016/j.saa.2019.04.081
Antunes, M. C. et al. Application of multivariate curve resolution to the voltammetric study of the complexation of fulvic acids with cadmium(II) ion. Anal. Chim. Acta 459, 291–304 (2002).
doi: 10.1016/S0003-2670(02)00117-4
Dicks, A., Hent, A. & Koroluk, K. The EcoScale as a framework for undergraduate green chemistry teaching and assessment. Green Chem. Lett. Rev. 11, 29–35 (2018).
doi: 10.1080/17518253.2018.1431313
Gałuszka, A. et al. Analytical eco-scale for assessing the greenness of analytical procedures. TrAC Trends Anal. Chem. 37, 61–72 (2012).
doi: 10.1016/j.trac.2012.03.013
Van Aken, K., Strekowski, L. & Patiny, L. EcoScale, a semi-quantitative tool to select an organic preparation based on economical and ecological parameters. Beilstein J. Org. Chem. 2, 3 (2006).
pubmed: 16542013
pmcid: 1409775
Pena-Pereira, F., Wojnowski, W. & Tobiszewski, M. AGREE—Analytical GREEnness metric approach and software. Anal. Chem. 92, 10076–10082 (2020).
pubmed: 32538619
pmcid: 7588019
doi: 10.1021/acs.analchem.0c01887
Imam, M. S. & Abdelrahman, M. M. How environmentally friendly is the analytical process? A paradigm overview of ten greenness assessment metric approaches for analytical methods. Trends Environ. Anal. Chem. 38, e00202 (2023).
doi: 10.1016/j.teac.2023.e00202