Rapid complete blood count and C-reactive protein determination with the Horiba Microsemi analyzer: the experience in neonatal intensive care unit of Careggi University Hospital.

C-reactive protein Complete blood count Hematology analyzer Microsystem Newborn Performance comparison

Journal

European journal of pediatrics
ISSN: 1432-1076
Titre abrégé: Eur J Pediatr
Pays: Germany
ID NLM: 7603873

Informations de publication

Date de publication:
15 Aug 2024
Historique:
received: 23 05 2024
accepted: 18 07 2024
revised: 12 07 2024
medline: 15 8 2024
pubmed: 15 8 2024
entrez: 14 8 2024
Statut: aheadofprint

Résumé

Microsystems represent an alternative but proficient approach of analysis outside the laboratory, and their use could help in reducing the impact of pre-analytical errors, in particular in challenging newborn samples. The study purpose is to compare the Horiba Microsemi CRP LC-767G system for rapid 3-part complete blood count (CBC) and C-reactive protein (CRP) determination with the laboratory reference systems (respectively Sysmex XN-9100™ and Roche Cobas® c702) in samples of adult patients and newborns hospitalized in the neonatal intensive care unit (NICU) samples. The comparison between the analyzers was performed through Passing-Bablok regression analysis and Bland-Altman plot. One hundred eighty-three blood samples were analyzed. The regression analysis results, performed in the newborn (n = 70) and in adult (n = 113) populations, showed a good agreement between the instruments. The evaluation of the Bland-Altman plots showed comparable values of bias < 10% for most of the parameters, but not for MPV, lymphocyte, and monocyte count. The comparison between the Microsemi CRP LC-767G system and the laboratory instrumentations demonstrated comparable results. The Microsemi CRP LC-767G system provides reliable analytical data and faster turnaround time, particularly useful in NICU. • Microsystems for point-of-care testing (POCT) represent an alternative but proficient approach of analysis outside the laboratory, in order to perform a rapid, safe, and exhaustive evaluation for critical patients' management, acting as a valid support for treatment in acute care. • The Microsemi CRP LC-767G system can represent an alternative but effective testing approach outside the laboratory, particularly in NICU, to reduce the impact of pre-analytical errors on newborn samples.

Identifiants

pubmed: 39143348
doi: 10.1007/s00431-024-05695-0
pii: 10.1007/s00431-024-05695-0
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© 2024. The Author(s).

Références

ISO 15189:2022 - Medical laboratories - requirements for quality and competence (2022) https://www.iso.org/standard/76677.html
Manucha V, Rusia U, Sikka M, Faridi MM, Madan N (2002) Utility of haematological parameters and C-reactive protein in the detection of neonatal sepsis. J Paediatr Child Health 38(5):459–464
doi: 10.1046/j.1440-1754.2002.00018.x pubmed: 12354261
Meraj F, Shaikh S, Maqsood S, Kanani F, Khan H, Jamal S (2023) Monocyte distribution width, a novel biomarker for early sepsis screening and comparison with procalcitonin and C-reactive protein. J Lab Physicians 15(2):294–299
doi: 10.1055/s-0042-1758666 pubmed: 37323592 pmcid: 10264128
Harnik E, Moreiras J (2014) Blood-taking procedures in children. Br J Hosp Med 75(9):C130–C132
doi: 10.12968/hmed.2014.75.9.C130
Giavarina D, Lippi G (2017) Blood venous sample collection: recommendations overview and a checklist to improve quality. Clin Biochem 50(10–11):568–573
doi: 10.1016/j.clinbiochem.2017.02.021 pubmed: 28242283
Carraro P, Plebani M (2007) Errors in a stat laboratory: types and frequencies 10 years later. Clin Chem 53(7):1338–1342
doi: 10.1373/clinchem.2007.088344 pubmed: 17525103
Lippi G, Chance JJ, Church S, Dazzi P, Fontana R, Giavarina D, Simundic AM (2011) Preanalytical quality improvement: from dream to reality. Clin Chem Lab Med 49(7):1113–1126
doi: 10.1515/CCLM.2011.600 pubmed: 21517699
Bahar B, Tuncel AF, Holmes EW, Holmes DT (2017) An interactive website for analytical method comparison and bias estimation. Clinical biochemistry 50(18):1025–9
doi: 10.1016/j.clinbiochem.2017.08.008 pubmed: 28823761
Vidali M, Tronchin M, Dittadi R, Gruppo di Studio SIBioC - Medicina di Laboratorio (2016) Protocollo per la comparazione di due metodi analitici di laboratorio. Biochimica Clinica 40(2):129–142
Shaw JLV (2015) Practical challenges related to point of care testing. Pract Lab Med 9(4):22–29
Cambridge T (2022) The future of point of care testing. Healthcare Transformers. https://healthcaretransformers.com/healthcare-business/strategy-and-operations/future-of-point-of-care-testing/
Oliver P, Fernandez-Calle P, Buno A (2021) POCT accreditation ISO 15189 and ISO 22870: making the point. EJIFCC 32(2):131–139
pubmed: 34421481 pmcid: 8343036
Rampoldi E, Patrucco G, Casati M, Morelli B, Carraro P, Gruppo di Studio Point of Care Testing (POCT) (2021) Principi per l’implementazione e la gestione del point-of-care-testing (POCT): indicazioni essenziali. Biochimica Clinica 45(3):312–326

Auteurs

Francesca Nencini (F)

General Laboratory, Careggi University Hospital, Florence, Italy.

Alessandro Bonari (A)

General Laboratory, Careggi University Hospital, Florence, Italy.

Francesca Romano (F)

General Laboratory, Careggi University Hospital, Florence, Italy.

Sara Ciullini Mannurita (S)

General Laboratory, Careggi University Hospital, Florence, Italy.

Alessandra Mongia (A)

General Laboratory, Careggi University Hospital, Florence, Italy.

Maria Garieri (M)

Division of Neonatology and Neonatal Intensive Care Unit, Careggi University Hospital, Florence, Italy.

Carlo Dani (C)

Division of Neonatology and Neonatal Intensive Care Unit, Careggi University Hospital, Florence, Italy. carlo.dani@unifi.it.
Department of Neurosciences, Psychology, Drug, Research and Child Health (NEUROFARBA), University of Florence, Viale Pieraccini, 6, Florence, Italy. carlo.dani@unifi.it.

Orazio Manzo (O)

General Laboratory, Careggi University Hospital, Florence, Italy.

Maria Pontieri (M)

General Laboratory, Careggi University Hospital, Florence, Italy.

Alessandra Fanelli (A)

General Laboratory, Careggi University Hospital, Florence, Italy.

Classifications MeSH