Equivalent Electrical Circuit Approach to Enhance a Transducer for Insulin Bioavailability Assessment.
Bioimpedance spectroscopy
diabetes
equivalent circuit approach
insulin bioavailability
metrological characterization
smart transducer
Journal
IEEE journal of translational engineering in health and medicine
ISSN: 2168-2372
Titre abrégé: IEEE J Transl Eng Health Med
Pays: United States
ID NLM: 101623153
Informations de publication
Date de publication:
2024
2024
Historique:
received:
28
02
2024
revised:
11
06
2024
accepted:
05
07
2024
medline:
19
8
2024
pubmed:
19
8
2024
entrez:
19
8
2024
Statut:
epublish
Résumé
The equivalent electrical circuit approach is explored to improve a bioimpedance-based transducer for measuring the bioavailability of synthetic insulin already presented in previous studies. In particular, the electrical parameter most sensitive to the variation of insulin amount injected was identified. Eggplants were used to emulate human electrical behavior under a quasi-static assumption guaranteed by a very low measurement time compared to the estimated insulin absorption time. Measurements were conducted with the EVAL-AD5940BIOZ by applying a sinusoidal voltage signal with an amplitude of 100 mV and acquiring impedance spectra in the range [1-100] kHz. 14 units of insulin were gradually administered using a Lilly's Insulin Pen having a 0.4 cm long needle. Modified Hayden's model was adopted as a reference circuit and the electrical component modeling the extracellular fluids was found to be the most insulin-sensitive parameter. The trnasducer achieves a state-of-the-art sensitivity of 225.90 ml1. An improvement of 223 % in sensitivity, 44 % in deterministic error, 7 % in nonlinearity, and 42 % in reproducibility was achieved compared to previous experimental studies. The clinical impact of the transducer was evaluated by projecting its impact on a Smart Insulin Pen for real-time measurement of insulin bioavailability. The wide gain in sensitivity of the bioimpedance-based transducer results in a significant reduction of the uncertainty of the Smart Insulin Pen. Considering the same improvement in in-vivo applications, the uncertainty of the Smart Insulin Pen is decreased from [Formula: see text]l to [Formula: see text]l.Clinical and Translational Impact Statement: A Smart Insulin Pen based on impedance spectroscopy and equivalent electrical circuit approach could be an effective solution for the non-invasive and real-time measurement of synthetic insulin uptake after subcutaneous administration.
Identifiants
pubmed: 39155919
doi: 10.1109/JTEHM.2024.3425269
pmc: PMC11329217
doi:
Substances chimiques
Insulin
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
533-541Informations de copyright
© 2024 The Authors.