High-sensitivity dual-comb and cross-comb spectroscopy across the infrared using a widely tunable and free-running optical parametric oscillator.


Journal

Nature communications
ISSN: 2041-1723
Titre abrégé: Nat Commun
Pays: England
ID NLM: 101528555

Informations de publication

Date de publication:
22 Aug 2024
Historique:
received: 21 09 2023
accepted: 05 08 2024
medline: 23 8 2024
pubmed: 23 8 2024
entrez: 22 8 2024
Statut: epublish

Résumé

Dual-comb spectroscopy (DCS) enables high-resolution measurements at high speeds without the trade-off between resolution and update rate inherent to mechanical delay scanning. However, high complexity and limited sensitivity remain significant challenges for DCS systems. We address these via a wavelength-tunable dual-comb optical parametric oscillator (OPO) combined with an up-conversion detection method. The OPO is tunable from 1300-1670 nm (signal) and 2700-5000 nm (idler). Spatial multiplexing in both the laser and OPO cavities creates a near-common path arrangement, enabling comb-line-resolved measurements in free-running operation. The narrow instantaneous bandwidth results in high power per comb-line up to 160 μW in the mid-infrared. Through intra-cavity up-conversion based on cross-comb spectroscopy, we leverage these power levels while overcoming the sensitivity limitations of direct mid-infrared detection. This approach yields a high signal-to-noise ratio (50.2 dB Hz

Identifiants

pubmed: 39174545
doi: 10.1038/s41467-024-51392-9
pii: 10.1038/s41467-024-51392-9
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

7211

Subventions

Organisme : Swiss National Science Foundation | National Center of Competence in Research Affective Sciences - Emotions in Individual Behaviour and Social Processes (National Centre of Competence in Research Affective Sciences)
ID : 40B2-0\_180933
Organisme : EC | EU Framework Programme for Research and Innovation H2020 | H2020 Priority Excellent Science | H2020 European Research Council (H2020 Excellent Science - European Research Council)
ID : 966718

Informations de copyright

© 2024. The Author(s).

Références

Coburn, S. et al. Regional trace-gas source attribution using a field-deployed dual frequency comb spectrometer. Optica 5, 320–327 (2018).
doi: 10.1364/OPTICA.5.000320
Ycas, G. et al. Mid-infrared dual-comb spectroscopy of volatile organic compounds across long open-air paths. Optica 6, 165–168 (2019).
doi: 10.1364/OPTICA.6.000165
Herman, D. I. et al. Open-path measurement of stable water isotopologues using mid-infrared dual-comb spectroscopy. Atmos. Meas. Tech. 16, 4053–4066 (2023).
doi: 10.5194/amt-16-4053-2023
Westberg, J. et al. Urban open-air chemical sensing using a mobile quantum cascade laser dual-comb spectrometer. APL Photonics 8, 120803 (2023).
doi: 10.1063/5.0163308
Mead, G. J. et al. Open-path dual-comb spectroscopy of methane and voc emissions from an unconventional oil well development in northern colorado. Front. Chem. 11, 1202255 (2023).
Schroeder, P. J. et al. Dual frequency comb laser absorption spectroscopy in a 16 MW gas turbine exhaust. Proc. Combust. Inst. 36, 4565–4573 (2017).
doi: 10.1016/j.proci.2016.06.032
Makowiecki, A. S. et al. Mid-infrared dual frequency comb spectroscopy for combustion analysis from 2.8 to 5 μm. Proc. Combust. Inst. 38, 1627–1635 (2021).
doi: 10.1016/j.proci.2020.06.195
Yun, D. et al. Thermometry and velocimetry in a ramjet using dual comb spectroscopy of the o2 a-band. Opt. Express 31, 42571–42580 (2023).
pubmed: 38087628 doi: 10.1364/OE.507647
Abbas, M. A. et al. Broadband time-resolved absorption and dispersion spectroscopy of methane and ethane in a plasma using a mid-infrared dual-comb spectrometer. Sensors 20, 6831 (2020).
Muraviev, A. V., Smolski, V. O., Loparo, Z. E. & Vodopyanov, K. L. Massively parallel sensing of trace molecules and their isotopologues with broadband subharmonic mid-infrared frequency combs. Nat. Photonics 12, 209–214 (2018).
doi: 10.1038/s41566-018-0135-2
Parriaux, A., Hammani, K., Thomazo, C., Musset, O. & Millot, G. Isotope ratio dual-comb spectrometer. Phys. Rev. Res. 4, 023098 (2022).
doi: 10.1103/PhysRevResearch.4.023098
Egbert, S. C., Sung, K., Coburn, S. C., Drouin, B. J. & Rieker, G. B. Water-vapor absorption database using dual comb spectroscopy from 300 to 1300 k part i: Pure h2o, 6600 to 7650 cm-1. J. Quant. Spectrosc. Radiat. Transf. 318, 108940 (2024).
doi: 10.1016/j.jqsrt.2024.108940
Villares, G., Hugi, A., Blaser, S. & Faist, J. Dual-comb spectroscopy based on quantum-cascade-laser frequency combs. Nat. Commun. 5, 1–9 (2014).
doi: 10.1038/ncomms6192
Sterczewski, L. A. et al. Mid-infrared dual-comb spectroscopy with interband cascade lasers. Opt. Lett. 44, 2113–2116 (2019).
pubmed: 30985824 doi: 10.1364/OL.44.002113
Yu, M. et al. Silicon-chip-based mid-infrared dual-comb spectroscopy. Nat. Commun. 9, 1–6 (2018).
Keilmann, F., Gohle, C. & Holzwarth, R. Time-domain mid-infrared frequency-comb spectrometer. Opt. Lett. 29, 1542–1544 (2004).
pubmed: 15259740 doi: 10.1364/OL.29.001542
Yan, M. et al. Mid-infrared dual-comb spectroscopy with electro-optic modulators. Light. Sci. Appl. 6, e17076 (2017).
pubmed: 30167208 pmcid: 6061907 doi: 10.1038/lsa.2017.76
Zhang, Z. et al. Asynchronous midinfrared ultrafast optical parametric oscillator for dual-comb spectroscopy. Opt. Lett. 37, 187–189 (2012).
pubmed: 22854462 doi: 10.1364/OL.37.000187
Jin, Y., Cristescu, S. M., Harren, F. J. M. & Mandon, J. Two-crystal mid-infrared optical parametric oscillator for absorption and dispersion dual-comb spectroscopy. Opt. Lett. 39, 3270–3270 (2014).
pubmed: 24876030 doi: 10.1364/OL.39.003270
Bernhardt, B. et al. Mid-infrared dual-comb spectroscopy with 2.4 μm Cr2+:ZnSe femtosecond lasers. Appl. Phys. B 100, 3–8 (2010).
doi: 10.1007/s00340-010-4080-0
Vasilyev, S. et al. Longwave infrared (6.6-11.4 μm) dual-comb spectroscopy with 240,000 comb-mode-resolved data points at video rate. Opt. Lett. 48, 2273–2276 (2023).
pubmed: 37126252 doi: 10.1364/OL.477346
Konnov, D., Muraviev, A., Vasilyev, S. & Vodopyanov, K. High-resolution frequency-comb spectroscopy with electro-optic sampling and instantaneous octave-wide coverage across mid-ir to thz at a video rate. APL Photonics 8, 110801 (2023).
Ycas, G. et al. High-coherence mid-infrared dual-comb spectroscopy spanning 2.6 to 5.2 μm. Nat. Photonics 12, 202–208 (2018).
doi: 10.1038/s41566-018-0114-7
Timmers, H. et al. Molecular fingerprinting with bright, broadband infrared frequency combs. Optica 5, 727–732 (2018).
doi: 10.1364/OPTICA.5.000727
Kowligy, A. S. et al. Infrared electric field sampled frequency comb spectroscopy. Sci. Adv. 5, eaaw8794 (2019).
pubmed: 31187063 pmcid: 6555623 doi: 10.1126/sciadv.aaw8794
Hoghooghi, N. et al. Complete reactants-to-products observation of a gas-phase chemical reaction with broad, fast mid-infrared frequency combs. arXiv https://arxiv.org/abs/2307.07029 (2023).
Newbury, N. R., Coddington, I. & Swann, W. Sensitivity of coherent dual-comb spectroscopy. Opt. Express 18, 7929–7945 (2010).
pubmed: 20588636 doi: 10.1364/OE.18.007929
Komagata, K. N., Wittwer, V. J., Südmeyer, T., Emmenegger, L. & Gianella, M. Absolute frequency referencing for swept dual-comb spectroscopy with midinfrared quantum cascade lasers. Phys. Rev. Res. 5, 013047 (2023).
doi: 10.1103/PhysRevResearch.5.013047
Hébert, N. B., Michaud-Belleau, V., Deschênes, J. D. & Genest, J. Self-correction limits in dual-comb interferometry. IEEE J. Quantum Electron. 55, 1–11 (2019).
doi: 10.1109/JQE.2019.2918935
Roy, J., Deschênes, J.-D., Potvin, S. & Genest, J. Continuous real-time correction and averaging for frequency comb interferometry. Opt. Express 20, 21932–21939 (2012).
pubmed: 23037343 doi: 10.1364/OE.20.021932
Hébert, N. B. et al. Self-corrected chip-based dual-comb spectrometer. Opt. Express 25, 8168–8179 (2017).
pubmed: 28380932 doi: 10.1364/OE.25.008168
Camenzind, S. L. et al. Free-running Yb:KYW dual-comb oscillator in a MOPA architecture. Opt. Express 31, 6633–6648 (2023).
pubmed: 36823915 doi: 10.1364/OE.482747
Phillips, C. R. et al. Coherently averaged dual-comb spectroscopy with a low-noise and high-power free-running gigahertz dual-comb laser. Opt. Express 31, 7103–7119 (2023).
pubmed: 36859848 doi: 10.1364/OE.479356
Benedick, A. J., Fujimoto, J. G. & Kärtner, F. X. Optical flywheels with attosecond jitter. Nat. Photonics 6, 97–100 (2012).
doi: 10.1038/nphoton.2011.326
Endo, M., Shoji, T. D. & Schibli, T. R. Ultralow noise optical frequency combs. IEEE J. Sel. Top. Quantum Electron. 24, 1–13 (2018).
doi: 10.1109/JSTQE.2018.2818461
Burneika, K., Ignatavicius, M., Kabelka, V., Piskarskas, A. & Stabinis, A. Parametric light amplification and oscillation in KDP with mode-locked pump. IEEE J. Quantum Electron. 8, 574–574 (1972).
doi: 10.1109/JQE.1972.1077077
Edelstein, D. C., Wachman, E. S. & Tang, C. L. Broadly tunable high repetition rate femtosecond optical parametric oscillator. Appl. Phys. Lett. 54, 1728–1730 (1989).
doi: 10.1063/1.101272
Dudley, J. M., Reid, D. T., Ebrahimzadeh, M. & Sibbett, W. Characteristics of a noncritically phasematched Ti: sapphire pumped femtosecond optical parametric oscillator. Opt. Commun. 104, 419–430 (1994).
doi: 10.1016/0030-4018(94)90578-9
Liao, R. et al. Dual-comb generation from a single laser source: principles and spectroscopic applications towards mid-IR-A review. J. Phys. Photonics 2, 042006 (2020).
doi: 10.1088/2515-7647/aba66e
Zhang, C. et al. Recent advances and outlook in single-cavity dual comb lasers. Photonics 10, 221 (2023).
Abbas, M. A. et al. Time-resolved mid-infrared dual-comb spectroscopy. Sci. Rep. 9, 17247 (2019).
pubmed: 31754263 pmcid: 6872568 doi: 10.1038/s41598-019-53825-8
Zhang, Z., Gardiner, T. & Reid, D. T. Mid-infrared dual-comb spectroscopy with an optical parametric oscillator. Opt. Lett. 38, 3148–3150 (2013).
pubmed: 24104672 doi: 10.1364/OL.38.003148
Jin, Y., Cristescu, S. M., Harren, F. J. M. & Mandon, J. Femtosecond optical parametric oscillators toward real-time dual-comb spectroscopy. Appl. Phys. B 119, 65–74 (2015).
doi: 10.1007/s00340-015-6035-y
Long, D. A. et al. Nanosecond time-resolved dual-comb absorption spectroscopy. Nat. Photonics 18, 127–131 (2024).
doi: 10.1038/s41566-023-01316-8
Bauer, C. P. et al. Dual-comb optical parametric oscillator in the mid-infrared based on a single free-running cavity. Opt. Express 30, 19904–19921 (2022).
pubmed: 36221754 doi: 10.1364/OE.459305
Pupeikis, J. et al. Spatially multiplexed single-cavity dual-comb laser. Optica 9, 713–716 (2022).
doi: 10.1364/OPTICA.457787
Kochanov, R. V. et al. HITRAN application programming interface (HAPI): a comprehensive approach to working with spectroscopic data. J. Quant. Spectrosc. Radiat. Transf. 177, 15–30 (2016).
doi: 10.1016/j.jqsrt.2016.03.005
Guay, P., Walsh, M., Tourigny-Plante, A. & Genest, J. Linear dual-comb interferometry at high power levels. Opt. Express 31, 4393–4404 (2023).
pubmed: 36785409 doi: 10.1364/OE.481671
Liu, M. et al. Mid-infrared cross-comb spectroscopy. Nat. Commun. 14, 1044 (2023).
pubmed: 36828826 pmcid: 9957991 doi: 10.1038/s41467-023-36811-7
Connes, P. High resolution and high information fourier spectroscopy. In: Handbook of high-resolution spectroscopy, 54 (1971).
Deschênes, J.-D., Giaccari, P. & Genest, J. Optical referencing technique with cw lasers as intermediate oscillators for continuous full delay range frequency comb interferometry. Opt. Express 18, 23358–23370 (2010).
pubmed: 21164677 doi: 10.1364/OE.18.023358
Keller, U. et al. Solid-state low-loss intracavity saturable absorber for Nd:YLF lasers: an antiresonant semiconductor Fabry-Perot saturable absorber. Opt. Lett. 17, 505–507 (1992).
pubmed: 19794540 doi: 10.1364/OL.17.000505
Keller, U. et al. Semiconductor saturable absorber mirrors (SESAM’s) for femtosecond to nanosecond pulse generation in solid-state lasers. IEEE J. Sel. Top. Quantum Electron. 2, 435–453 (1996).
doi: 10.1109/2944.571743
Shoji, T. D. et al. Ultra-low-noise monolithic mode-locked solid-state laser. Optica 3, 995–998 (2016).
doi: 10.1364/OPTICA.3.000995
Nitzsche, L. et al. Tunable dual-comb spectrometer for mid-infrared trace gas analysis from 3 to 4.7 μm. Opt. Express 29, 25449–25461 (2021).
pubmed: 34614876 doi: 10.1364/OE.428709
Gordon, I. E. et al. The HITRAN2020 molecular spectroscopic database. J. Quant. Spectrosc. Radiat. Transf. 277, 107949 (2022).
doi: 10.1016/j.jqsrt.2021.107949
Millot, G. et al. Frequency-agile dual-comb spectroscopy. Nat. Photonics 10, 27–30 (2016).
doi: 10.1038/nphoton.2015.250
Chen, Z., Hänsch, T. W. & Picqué, N. Upconversion mid-infrared dual-comb spectroscopy. arXiv https://arxiv.org/abs/2003.06930 (2020).
Winzer, P. J. Shot-noise formula for time-varying photon rates: a general derivation. J. Opt. Soc. Am. B 14, 2424–2429 (1997).
doi: 10.1364/JOSAB.14.002424
Zurich, E. Research collection (2024). https://www.research-collection.ethz.ch/ .

Auteurs

Carolin P Bauer (CP)

Department of Physics, Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland. cabauer@phys.ethz.ch.

Zofia A Bejm (ZA)

Department of Physics, Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland.

Michelle K Bollier (MK)

Department of Physics, Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland.

Justinas Pupeikis (J)

Department of Physics, Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland.

Benjamin Willenberg (B)

Department of Physics, Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland.

Ursula Keller (U)

Department of Physics, Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland.

Christopher R Phillips (CR)

Department of Physics, Institute for Quantum Electronics, ETH Zurich, Zurich, Switzerland.

Classifications MeSH