Flow quantification within the aortic ejection tract using 4D flow cardiac MRI in patients with bicuspid aortic valve: Implications for the assessment of aortic regurgitation.
4D flow cardiac MRI
Aortic valve insufficiency
Bicuspid aortic valve disease
Cardiac magnetic resonance imaging
Journal
Diagnostic and interventional imaging
ISSN: 2211-5684
Titre abrégé: Diagn Interv Imaging
Pays: France
ID NLM: 101568499
Informations de publication
Date de publication:
12 Sep 2024
12 Sep 2024
Historique:
received:
22
04
2024
revised:
05
08
2024
accepted:
03
09
2024
medline:
14
9
2024
pubmed:
14
9
2024
entrez:
13
9
2024
Statut:
aheadofprint
Résumé
The purpose of this study was to evaluate the performance of four-dimensional (4D) flow cardiac MRI in quantifying aortic flow in patients with bicuspid aortic valve (BAV). Patients with BAV who underwent transthoracic echocardiography (TTE) and 4D flow cardiac MRI were prospectively included. Aortic flow was quantified using two-dimensional phase contrast velocimetry at the sinotubular junction and in the ascending aorta and using 4D flow in the regurgitant jet, in the left ventricular outflow tract, at the aortic annulus, the sinotubular junction, and the ascending aorta, with or without anatomical tracking. Flow quantification was compared with ventricular volumes, pulmonary flow using Pearson correlation test, bias and limits of agreement (LOA) using Bland Altman method, and with multiparametric transthoracic echocardiography quantification using weighted kappa test. Eighty-eight patients (63 men, 25 women) with a mean age of 50.5 ± 14.8 (standard deviation) years (age range: 20.8-78.3) were included. Changes in flow with or without tracking were modest (< 5 mL). The best correlation was obtained at the aortic annulus for forward volume (r = 0.84; LOA [-28.4; 25.3] mL) and at the regurgitant jet and sinotubular junction for regurgitant volume (r = 0.68; LOA [-27.8; 33.8] and r = 0.69; LOA [-28.6; 24.2] mL). A combined approach for regurgitant fraction and net volume calculations using forward volume measured at ANN and regurgitant volume at sinotubular junction performed better than each level taken separately (r = 0.90; LOA [-20.7; 10.0] mL and r = 0.48, LOA [-33.8; 33.4] %). The agreement between transthoracic echocardiography and 4D flow cardiac MRI for aortic regurgitation grading was poor (kappa, 0.13 to 0.42). In patients with BAV, aortic flow quantification by 4D flow cardiac MRI is the most accurate at the annulus for the forward volume, and at the sinotubular junction or directly in the jet for the regurgitant volume.
Identifiants
pubmed: 39271367
pii: S2211-5684(24)00194-3
doi: 10.1016/j.diii.2024.09.001
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.