Hybrid-3D robotic suite in spine and trauma surgery - experiences in 210 patients.


Journal

Journal of orthopaedic surgery and research
ISSN: 1749-799X
Titre abrégé: J Orthop Surg Res
Pays: England
ID NLM: 101265112

Informations de publication

Date de publication:
14 Sep 2024
Historique:
received: 14 07 2024
accepted: 31 08 2024
medline: 14 9 2024
pubmed: 14 9 2024
entrez: 13 9 2024
Statut: epublish

Résumé

In modern Hybrid ORs, the synergies of navigation and robotics are assumed to contribute to the optimisation of the treatment in trauma, orthopaedic and spine surgery. Despite promising evidence in the area of navigation and robotics, previous publications have not definitively proven the potential benefits. Therefore, the aim of this retrospective study was to evaluate the potential benefit and clinical outcome of patients treated in a fully equipped 3D-Navigation Hybrid OR. Prospective data was collected (March 2022- March 2024) after implementation of a fully equipped 3D-Navigation Hybrid OR ("Robotic Suite") in the authors level 1 trauma centre. The OR includes a navigation unit, a cone beam CT (CBCT), a robotic arm and mixed reality glasses. Surgeries with different indications of the spine, the pelvis (pelvic ring and acetabulum) and the extremities were performed. Spinal and non-spinal screws were inserted. The collected data was analysed retrospectively. Pedicle screw accuracy was graded according to the Gertzbein and Robbins (GR) classification. A total of n = 210 patients (118 m:92f) were treated in our 3D-Navigation Hybrid OR, with 1171 screws inserted. Among these patients, 23 patients (11.0%) arrived at the hospital via the trauma room with an average Injury Severity Score (ISS) of 25.7. There were 1035 (88.4%) spinal screws inserted at an accuracy rate of 98.7% (CI95%: 98.1-99.4%; 911 GR-A & 111 GR-B screws). The number of non-spinal screws were 136 (11.6%) with an accuracy rate of 99.3% (CI95%: 97.8-100.0%; 135 correctly placed screws). This resulted in an overall accuracy rate of 98.8% (CI95%: 98.2-99.4%). The robotic arm was used in 152 cases (72.4%), minimally invasive surgery (MIS) was performed in 139 cases (66.2%) and wound infection occurred in 4 cases (1,9%). Overall, no revisions were needed. By extending the scope of application, this study showed that interventions in a fully equipped 3D-Navigation Hybrid OR can be successfully performed not only on the spine, but also on the pelvis and extremities. In trauma, orthopaedics and spinal surgery, navigation and robotics can be used to perform operations with a high degree of precision, increased safety, reduced radiation exposure for the OR-team and a very low complication rate.

Sections du résumé

BACKGROUND BACKGROUND
In modern Hybrid ORs, the synergies of navigation and robotics are assumed to contribute to the optimisation of the treatment in trauma, orthopaedic and spine surgery. Despite promising evidence in the area of navigation and robotics, previous publications have not definitively proven the potential benefits. Therefore, the aim of this retrospective study was to evaluate the potential benefit and clinical outcome of patients treated in a fully equipped 3D-Navigation Hybrid OR.
METHODS METHODS
Prospective data was collected (March 2022- March 2024) after implementation of a fully equipped 3D-Navigation Hybrid OR ("Robotic Suite") in the authors level 1 trauma centre. The OR includes a navigation unit, a cone beam CT (CBCT), a robotic arm and mixed reality glasses. Surgeries with different indications of the spine, the pelvis (pelvic ring and acetabulum) and the extremities were performed. Spinal and non-spinal screws were inserted. The collected data was analysed retrospectively. Pedicle screw accuracy was graded according to the Gertzbein and Robbins (GR) classification.
RESULTS RESULTS
A total of n = 210 patients (118 m:92f) were treated in our 3D-Navigation Hybrid OR, with 1171 screws inserted. Among these patients, 23 patients (11.0%) arrived at the hospital via the trauma room with an average Injury Severity Score (ISS) of 25.7. There were 1035 (88.4%) spinal screws inserted at an accuracy rate of 98.7% (CI95%: 98.1-99.4%; 911 GR-A & 111 GR-B screws). The number of non-spinal screws were 136 (11.6%) with an accuracy rate of 99.3% (CI95%: 97.8-100.0%; 135 correctly placed screws). This resulted in an overall accuracy rate of 98.8% (CI95%: 98.2-99.4%). The robotic arm was used in 152 cases (72.4%), minimally invasive surgery (MIS) was performed in 139 cases (66.2%) and wound infection occurred in 4 cases (1,9%). Overall, no revisions were needed.
CONCLUSION CONCLUSIONS
By extending the scope of application, this study showed that interventions in a fully equipped 3D-Navigation Hybrid OR can be successfully performed not only on the spine, but also on the pelvis and extremities. In trauma, orthopaedics and spinal surgery, navigation and robotics can be used to perform operations with a high degree of precision, increased safety, reduced radiation exposure for the OR-team and a very low complication rate.

Identifiants

pubmed: 39272126
doi: 10.1186/s13018-024-05044-9
pii: 10.1186/s13018-024-05044-9
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

565

Informations de copyright

© 2024. The Author(s).

Références

Settmacher U. [Hybrid operation theatre]. Chirurg. 2013;84(12):1020–1.
pubmed: 24220953 doi: 10.1007/s00104-013-2553-5
Richter PH, Gebhard F. [The interdisciplinary hybrid operation theatre. Current experience and future]. Chirurg, 2013. 84(12): pp. 1036-40.
Marketos SG, Skiadas P. Hippocrates. The father of spine surgery. Spine (Phila Pa 1976). 1999;24(13):1381–7.
pubmed: 10404583 doi: 10.1097/00007632-199907010-00018
Tarpada SP, Morris MT, Burton DA. Spinal fusion surgery: a historical perspective. J Orthop. 2017;14(1):134–6.
pubmed: 27872518 doi: 10.1016/j.jor.2016.10.029
Markham JW. The history of laminectomy prior to 1866. Bull Hist Med. 1952;26(4):375–84.
pubmed: 14954289
Walker CT, et al. History and advances in spinal neurosurgery. J Neurosurg Spine. 2019;31(6):775–85.
pubmed: 31786543 doi: 10.3171/2019.9.SPINE181362
Enchev Y. Neuronavigation: geneology, reality, and prospects. Neurosurg Focus. 2009;27(3):E11.
pubmed: 19722813 doi: 10.3171/2009.6.FOCUS09109
Mao JZ, et al. Technologic Evolution of Navigation and Robotics in spine surgery: a historical perspective. World Neurosurg. 2021;145:159–67.
pubmed: 32916361 doi: 10.1016/j.wneu.2020.08.224
Haemmerli J, et al. Comparison of intraoperative CT- and cone beam CT-based spinal navigation for the treatment of atlantoaxial instability. Spine J. 2023;23(12):1799–807.
pubmed: 37619869 doi: 10.1016/j.spinee.2023.08.010
Morrell ALG, et al. The history of robotic surgery and its evolution: when illusion becomes reality. Rev Col Bras Cir. 2021;48:e20202798.
pubmed: 33470371 pmcid: 10683436 doi: 10.1590/0100-6991e-20202798
Staub BN, Sadrameli SS. The use of robotics in minimally invasive spine surgery. J Spine Surg. 2019;5(Suppl 1):S31–40.
pubmed: 31380491 pmcid: 6626754 doi: 10.21037/jss.2019.04.16
Oh BK, et al. A single-center experience of robotic-assisted spine surgery in Korea: analysis of Screw Accuracy, potential risk factor of Screw Malposition and learning curve. J Korean Neurosurg Soc. 2024;67(1):60–72.
pubmed: 38224963 doi: 10.3340/jkns.2023.0128
Kantelhardt SR, et al. Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placement. Eur Spine J. 2011;20(6):860–8.
pubmed: 21384205 pmcid: 3099153 doi: 10.1007/s00586-011-1729-2
Shin BJ, et al. Pedicle screw navigation: a systematic review and meta-analysis of perforation risk for computer-navigated versus freehand insertion. J Neurosurg Spine. 2012;17(2):113–22.
pubmed: 22724594 doi: 10.3171/2012.5.SPINE11399
Luther N, et al. Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech. 2015;28(5):E298–303.
pubmed: 23511642 doi: 10.1097/BSD.0b013e31828af33e
Bredow J, et al. The accuracy of 3D fluoroscopy-navigated screw insertion in the upper and subaxial cervical spine. Eur Spine J. 2015;24(12):2967–76.
pubmed: 25925249 doi: 10.1007/s00586-015-3974-2
Tkatschenko D, et al. Navigated percutaneous versus open pedicle screw implantation using intraoperative CT and robotic cone-beam CT imaging. Eur Spine J. 2020;29(4):803–12.
pubmed: 31820094 doi: 10.1007/s00586-019-06242-4
Pojskić M et al. Initial Intraoperative Experience with Robotic-Assisted Pedicle Screw Placement with Cirq(
Farah K, et al. Robotic assistance for minimally invasive cervical pedicle instrumentation: report on feasibility and safety. World Neurosurg. 2021;150:e777–82.
pubmed: 33831617 doi: 10.1016/j.wneu.2021.03.150
Abel F, et al. Robotic-navigated assistance in spine surgery. Bone Joint J. 2023;105–b(5):543–50.
pubmed: 37121590 doi: 10.1302/0301-620X.105B5.BJJ-2022-0810.R3
Gabrovsky N, Ilkov P, Laleva M. Cirq
pubmed: 37383441 pmcid: 10293294 doi: 10.1016/j.bas.2023.101717
Wang X et al. Effectiveness and safety of robot-assisted versus fluoroscopy-assisted cortical bone trajectory screw instrumentation in spinal surgery: a systematic review and meta-analysis. J Robotic Surg, 2024. 18(1).
Alaei P, Spezi E. Imaging dose from cone beam computed tomography in radiation therapy. Phys Med. 2015;31(7):647–58.
pubmed: 26148865 doi: 10.1016/j.ejmp.2015.06.003
Gertzbein SD, Robbins SE. Accuracy of pedicular screw placement in vivo. Spine (Phila Pa 1976). 1990;15(1):11–4.
pubmed: 2326693 doi: 10.1097/00007632-199001000-00004
Onyekwelu I, et al. Surgical Wound classification and Surgical Site infections in the Orthopaedic Patient. J Am Acad Orthop Surg Glob Res Rev. 2017;1(3):e022.
pubmed: 30211353 pmcid: 6132296
Schupper AJ, et al. Improving Surgeon Well-Being: Ergonomics in Neurosurgery. World Neurosurg. 2023;175:e1220–5.
pubmed: 37427701 doi: 10.1016/j.wneu.2023.04.102
Mengis-Palleck CL, et al. Surgical Site infection after Polymethyl Methacrylate Pedicle Screw Augmentation in osteoporotic spinal vertebrae: a Series of 537 cases. Int J Spine Surg. 2023;17(4):587–97.
pubmed: 37217274 pmcid: 10478696 doi: 10.14444/8474
Janssen IK, et al. Minimally invasive posterior pedicle screw fixation versus open instrumentation in patients with thoracolumbar spondylodiscitis. Acta Neurochir (Wien). 2021;163(6):1553–60.
pubmed: 33655377 doi: 10.1007/s00701-021-04744-z
Akazawa T et al. Safety of robotic-assisted screw placement for spine surgery: experience from the initial 125 cases. J Orthop Sci, 2023.
Jung B, et al. Robotic-assisted Versus Fluoroscopic-guided surgery on the Accuracy of Spine Pedicle Screw Placement: a systematic review and Meta-analysis. Cureus. 2024;16(2):e54969.
pubmed: 38410625 pmcid: 10896625
Lopez IB, et al. Robotics in spine surgery: systematic review of literature. Int Orthop. 2023;47(2):447–56.
pubmed: 35849162 doi: 10.1007/s00264-022-05508-9
Beyer RS, et al. Spinal robotics in cervical spine surgery: a systematic review with key concepts and technical considerations. J Neurosurg Spine. 2023;38(1):66–74.
pubmed: 36087333 doi: 10.3171/2022.7.SPINE22473
Zhou LP, et al. Clinical application of spinal robot in cervical spine surgery: safety and accuracy of posterior pedicle screw placement in comparison with conventional freehand methods. Neurosurg Rev. 2023;46(1):118.
pubmed: 37166553 doi: 10.1007/s10143-023-02027-y
Asada T, et al. Robot-navigated pedicle screw insertion can reduce intraoperative blood loss and length of hospital stay: analysis of 1,633 patients utilizing propensity score matching. Spine J. 2024;24(1):118–24.
pubmed: 37704046 doi: 10.1016/j.spinee.2023.09.004
Mendelsohn D, et al. Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation. Spine J. 2016;16(3):343–54.
pubmed: 26686604 doi: 10.1016/j.spinee.2015.11.020
Elbakri IA, Kirkpatrick ID. Dose-length product to effective dose conversion factors for common computed tomography examinations based on Canadian clinical experience. Can Assoc Radiol J. 2013;64(1):15–7.
pubmed: 22406136 doi: 10.1016/j.carj.2011.12.013
Compagnone G, et al. Calculation of conversion factors for effective dose for various interventional radiology procedures. Med Phys. 2012;39(5):2491–8.
pubmed: 22559619 doi: 10.1118/1.3702457
Chen DS, et al. Dose-area product-to-effective dose Conversion coefficients for pelvic radiography using a Monte Carlo Program. AJR Am J Roentgenol. 2020;215(3):679–84.
pubmed: 32755183 doi: 10.2214/AJR.19.22013
Huber-Wagner S, et al. Effect of whole-body CT during trauma resuscitation on survival: a retrospective, multicentre study. Lancet. 2009;373(9673):1455–61.
pubmed: 19321199 doi: 10.1016/S0140-6736(09)60232-4
Pape HC, et al. Pathophysiology in patients with polytrauma. Injury. 2022;53(7):2400–12.
pubmed: 35577600 doi: 10.1016/j.injury.2022.04.009
Jones EL, et al. Cervical pedicle screws versus lateral mass screws. Anatomic feasibility and biomechanical comparison. Spine (Phila Pa 1976). 1997;22(9):977–82.
pubmed: 9152447 doi: 10.1097/00007632-199705010-00009
Zhou LP, et al. Robotics in cervical spine surgery: feasibility and safety of posterior screw Placement. Neurospine. 2023;20(1):329–39.
pubmed: 37016881 pmcid: 10080448 doi: 10.14245/ns.2244952.476
Garg B, Mehta N, Malhotra R. Robotic spine surgery: ushering in a new era. J Clin Orthop Trauma. 2020;11(5):753–60.
pubmed: 32904238 pmcid: 7452360 doi: 10.1016/j.jcot.2020.04.034
Farah K, et al. Cirq
pubmed: 32710770 doi: 10.1093/ons/opaa208
Wu J et al. Accuracy and clinical characteristics of robot-assisted cervical spine surgery: a systematic review and meta-analysis. Int Orthop, 2024.
Chesney K, et al. Cirq robotic arm-assisted transpedicular instrumentation with intraoperative navigation: technical note and case series with 714 thoracolumbar screws. J Robot Surg. 2022;16(4):893–8.
pubmed: 34606045 doi: 10.1007/s11701-021-01313-5
Devito DP, et al. Clinical acceptance and accuracy assessment of spinal implants guided with SpineAssist surgical robot: retrospective study. Spine (Phila Pa 1976). 2010;35(24):2109–15.
pubmed: 21079498 doi: 10.1097/BRS.0b013e3181d323ab
Kanaly CW, et al. A retrospective analysis of Pedicle Screw Placement Accuracy using the ExcelsiusGPS Robotic Guidance System: Case Series. Oper Neurosurg (Hagerstown). 2023;24(3):242–7.
pubmed: 36454079 doi: 10.1227/ons.0000000000000498
Vardiman AB, et al. Pedicle screw accuracy in clinical utilization of minimally invasive navigated robot-assisted spine surgery. J Robot Surg. 2020;14(3):409–13.
pubmed: 31321615 doi: 10.1007/s11701-019-00994-3
Perdomo-Pantoja A, et al. Accuracy of current techniques for Placement of Pedicle screws in the spine: a comprehensive systematic review and Meta-analysis of 51,161 screws. World Neurosurg. 2019;126:664–e6783.
pubmed: 30880208 doi: 10.1016/j.wneu.2019.02.217
Naik A, et al. Trends in Technology for Pedicle Screw Placement: a temporal Meta-analysis. Spine (Phila Pa 1976). 2023;48(11):791–9.
pubmed: 36799728
Gilani S, et al. The Use of a robotic arm for fixation of pelvic fractures. J Orthop Trauma. 2023;37(11s):S28–32.
pubmed: 37828699 doi: 10.1097/BOT.0000000000002691
Yu T, et al. Computer navigation-assisted minimally invasive percutaneous screw placement for pelvic fractures. World J Clin Cases. 2020;8(12):2464–72.
pubmed: 32607323 pmcid: 7322419 doi: 10.12998/wjcc.v8.i12.2464
Schuijt HJ, et al. Robot-assisted fracture fixation in orthopaedic trauma surgery: a systematic review. OTA Int. 2021;4(4):e153.
pubmed: 34765903 pmcid: 8575426 doi: 10.1097/OI9.0000000000000153
Küper MA, et al. Robotic-assisted plate osteosynthesis of the anterior pelvic ring and acetabulum: an anatomical feasibility study. J Robot Surg. 2022;16(6):1401–7.
pubmed: 35147842 doi: 10.1007/s11701-022-01381-1
Smith AF, Carlson JB. Robotic-assisted percutaneous pelvis fixation: a case report. Clin Case Rep. 2023;11(6):e7527.
pubmed: 37323256 pmcid: 10264929 doi: 10.1002/ccr3.7527
Lee NJ, et al. The accuracy of robot-assisted S2 alar-iliac screw placement at two different healthcare centers. J Spine Surg. 2021;7(3):326–34.
pubmed: 34734137 pmcid: 8511558 doi: 10.21037/jss-21-14
Laratta JL, et al. Accuracy of S2 Alar-Iliac Screw Placement under Robotic Guidance. Spine Deform. 2018;6(2):130–6.
pubmed: 29413734 doi: 10.1016/j.jspd.2017.08.009
Bederman SS, et al. Robotic Guidance for S2-Alar-iliac screws in spinal deformity correction. Clin Spine Surg. 2017;30(1):E49–53.
pubmed: 28107243 doi: 10.1097/BSD.0b013e3182a3572b
Arora A, Berven S. Challenges and complications in Freehand S2-Alar-iliac spinopelvic fixation and the potential for Robotics to Enhance Patient Safety. Global Spine J. 2022;12(2suppl):s45–52.
doi: 10.1177/21925682211036664
Fiani B, et al. Impact of robot-assisted spine surgery on health care quality and neurosurgical economics: a systemic review. Neurosurg Rev. 2020;43(1):17–25.
pubmed: 29611081 doi: 10.1007/s10143-018-0971-z
Zhang Q, et al. Comparison of Superior-Level Facet Joint violations between Robot-assisted Percutaneous Pedicle Screw Placement and Conventional Open fluoroscopic-guided Pedicle Screw Placement. Orthop Surg. 2019;11(5):850–6.
pubmed: 31663290 pmcid: 6819175 doi: 10.1111/os.12534
Ahern DP, et al. Image-guidance, Robotics, and the future of spine surgery. Clin Spine Surg. 2020;33(5):179–84.
pubmed: 31425306 doi: 10.1097/BSD.0000000000000809
Fan M, et al. Improved accuracy of cervical spinal surgery with Robot-assisted screw insertion: a prospective, randomized, controlled study. Spine (Phila Pa 1976). 2020;45(5):285–91.
pubmed: 31568094 doi: 10.1097/BRS.0000000000003258

Auteurs

Dominik M Haida (DM)

Department of Trauma Surgery, Technical University of Munich, Klinikum rechts der Isar, Ismaninger Straße 22, 81675, Munich, Germany.
Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany.

Peter Mohr (P)

Radiation Protection, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany.

Sae-Yeon Won (SY)

Department of Neurosurgery, Rostock University Medical Center, Schillingallee 35, 18057, Rostock, Germany.

Thorsten Möhlig (T)

Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany.

Mike Holl (M)

Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany.

Thorsten Enk (T)

Department of Neurosurgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany.

Marc Hanschen (M)

Department of Trauma Surgery, Technical University of Munich, Klinikum rechts der Isar, Ismaninger Straße 22, 81675, Munich, Germany.

Stefan Huber-Wagner (S)

Department of Trauma Surgery, Technical University of Munich, Klinikum rechts der Isar, Ismaninger Straße 22, 81675, Munich, Germany. s.huber-wagner@tum.de.
Department of Trauma Surgery, Diakonie-Klinikum Schwäbisch Hall, Diakoniestraße 10, 74523, Schwäbisch Hall, Germany. s.huber-wagner@tum.de.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH