Computational techniques to monitoring fractional order type-1 diabetes mellitus model for feedback design of artificial pancreas.
Artificial pancreas
Diabetes type 1
Existence
Fractal fractional operator
Stability
Uniqueness
Journal
Computer methods and programs in biomedicine
ISSN: 1872-7565
Titre abrégé: Comput Methods Programs Biomed
Pays: Ireland
ID NLM: 8506513
Informations de publication
Date de publication:
14 Sep 2024
14 Sep 2024
Historique:
received:
12
07
2024
revised:
03
09
2024
accepted:
09
09
2024
medline:
21
9
2024
pubmed:
21
9
2024
entrez:
20
9
2024
Statut:
aheadofprint
Résumé
In this paper, we developed a significant class of control issues regulated by nonlinear fractal order systems with input and output signals, our goal is to design a direct transcription method with impulsive instant order. Recent advances in the artificial pancreas system provide an emerging treatment option for type 1 diabetes. The performance of the blood glucose regulation directly relies on the accuracy of the glucose-insulin modeling. This work leads to the monitoring and assessment of comprehensive type-1 diabetes mellitus for controller design of artificial panaceas for the precision of the glucose-insulin glucagon in finite time with Caputo fractional approach for three primary subsystems. For the proposed model, we admire the qualitative analysis with equilibrium points lying in the feasible region. Model satisfied the biological feasibility with the Lipschitz criteria and linear growth is examined, considering positive solutions, boundedness and uniqueness at equilibrium points with Leray-Schauder results under time scale ideas. Within each subsystem, the virtual control input laws are derived by the application of input to state theorems and Ulam Hyers Rassias. Chaotic Relation of Glucose insulin glucagon compartmental in the feasible region and stable in finite time interval monitoring is derived through simulations that are stable and bounded in the feasible regions. Additionally, as blood glucose is the only measurable state variable, the unscented power-law kernel estimator appropriately takes into account the significant problem of estimating inaccessible state variables that are bound to significant values for the glucose-insulin system. The comparative results on the simulated patients suggest that the suggested controller strategy performs remarkably better than the compared methods. In the model under investigation, parametric uncertainties are identified since the glucose, insulin, and glucagon system's parameters are accurately measured numerically at different fractional order values. In terms of algorithm resilience and Caputo tracking in the presence of glucagon and insulin intake disturbance to maintain the glucose level. A comprehensive analysis of numerous difficult test issues is conducted in order to offer a thorough justification of the planned strategy to control the type 1 diabetes mellitus with designed the artificial pancreas.
Sections du résumé
BACKGROUND AND OBJECTIVES
OBJECTIVE
In this paper, we developed a significant class of control issues regulated by nonlinear fractal order systems with input and output signals, our goal is to design a direct transcription method with impulsive instant order. Recent advances in the artificial pancreas system provide an emerging treatment option for type 1 diabetes. The performance of the blood glucose regulation directly relies on the accuracy of the glucose-insulin modeling. This work leads to the monitoring and assessment of comprehensive type-1 diabetes mellitus for controller design of artificial panaceas for the precision of the glucose-insulin glucagon in finite time with Caputo fractional approach for three primary subsystems.
METHODS
METHODS
For the proposed model, we admire the qualitative analysis with equilibrium points lying in the feasible region. Model satisfied the biological feasibility with the Lipschitz criteria and linear growth is examined, considering positive solutions, boundedness and uniqueness at equilibrium points with Leray-Schauder results under time scale ideas. Within each subsystem, the virtual control input laws are derived by the application of input to state theorems and Ulam Hyers Rassias.
RESULTS
RESULTS
Chaotic Relation of Glucose insulin glucagon compartmental in the feasible region and stable in finite time interval monitoring is derived through simulations that are stable and bounded in the feasible regions. Additionally, as blood glucose is the only measurable state variable, the unscented power-law kernel estimator appropriately takes into account the significant problem of estimating inaccessible state variables that are bound to significant values for the glucose-insulin system. The comparative results on the simulated patients suggest that the suggested controller strategy performs remarkably better than the compared methods.
CONCLUSION
CONCLUSIONS
In the model under investigation, parametric uncertainties are identified since the glucose, insulin, and glucagon system's parameters are accurately measured numerically at different fractional order values. In terms of algorithm resilience and Caputo tracking in the presence of glucagon and insulin intake disturbance to maintain the glucose level. A comprehensive analysis of numerous difficult test issues is conducted in order to offer a thorough justification of the planned strategy to control the type 1 diabetes mellitus with designed the artificial pancreas.
Identifiants
pubmed: 39303363
pii: S0169-2607(24)00413-9
doi: 10.1016/j.cmpb.2024.108420
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
108420Informations de copyright
Copyright © 2024 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.