Photon-counting CT systems: A technical review of current clinical possibilities.

Computed tomography Dual-energy CT Image quality Photon counting CT Spectral photon counting CT

Journal

Diagnostic and interventional imaging
ISSN: 2211-5684
Titre abrégé: Diagn Interv Imaging
Pays: France
ID NLM: 101568499

Informations de publication

Date de publication:
20 Sep 2024
Historique:
received: 12 08 2024
accepted: 03 09 2024
medline: 21 9 2024
pubmed: 21 9 2024
entrez: 20 9 2024
Statut: aheadofprint

Résumé

In recent years, computed tomography (CT) has undergone a number of developments to improve radiological care. The most recent major innovation has been the development of photon-counting detectors. By comparison with the energy-integrating detectors traditionally used in CT, these detectors offer better dose efficiency, eliminate electronic noise, improve spatial resolution and have intrinsic spectral sensitivity. These detectors also allow the energy of each photon to be counted, thus improving the sampling of the X-ray spectrum in multiple energy bins, to better distinguish between photoelectric and Compton attenuation coefficients, resulting in better spectral images and specific color K-edge images. The purpose of this article was to make the reader more familiar with the basic principles and techniques of new photon-counting CT systems equipped with photon-counting detectors and also to describe the currently available devices that could be used in clinical practice.

Identifiants

pubmed: 39304365
pii: S2211-5684(24)00195-5
doi: 10.1016/j.diii.2024.09.002
pii:
doi:

Types de publication

Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

Copyright © 2024 The Author(s). Published by Elsevier Masson SAS.. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors have no relevant conflict of interest to disclose in relation with this article.

Auteurs

Joël Greffier (J)

IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30900 Nîmes, France. Electronic address: joel.greffier@chu-nimes.fr.

Anaïs Viry (A)

Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, 1007 Lausanne, Switzerland.

Antoine Robert (A)

University of Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, 69621 Villeurbanne, France.

Mouad Khorsi (M)

Institute of Radiation Physics, Lausanne University Hospital and University of Lausanne, 1007 Lausanne, Switzerland.

Salim Si-Mohamed (S)

University of Lyon, INSA-Lyon, University Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, 69621 Villeurbanne, France; Department of Radiology, Louis Pradel Hospital, Hospices Civils de Lyon, 69500 Bron, France.

Classifications MeSH