Optimal combination of microcoils, flow control, and n-butyl cyanoacrylate-Lipiodol-iopamidol (2:3:1) for feasible embolization of medium-sized arteries in an in vitro vascular model.

Embolization Flow control Medium-sized arteries Microcoils N-butyl cyanoacrylate–Lipiodol–iopamidol

Journal

Japanese journal of radiology
ISSN: 1867-108X
Titre abrégé: Jpn J Radiol
Pays: Japan
ID NLM: 101490689

Informations de publication

Date de publication:
28 Sep 2024
Historique:
received: 05 07 2024
accepted: 19 09 2024
medline: 28 9 2024
pubmed: 28 9 2024
entrez: 28 9 2024
Statut: aheadofprint

Résumé

To evaluate the behavior of n-butyl cyanoacrylate-Lipiodol-iopamidol at a ratio of 2:3:1 (NLI231) with and without microcoils and/or flow control in embolization of medium-sized arteries in an in vitro vascular model. A vessel model representing a common hepatic artery was prepared. Six scenarios were set for embolization, each ran three times: 1) NLI231 injected alone with flow control to 0 ml/min during and up to 5 min after embolization; 2) NLI231 injected into a mesh of microcoil of 5% density with the flow control; 3) NLI231 injected into a microcoil of 10% density with the flow control; 4) NLI231 injected alone without the flow control; 5) NLI231 injected into microcoil of 5% density without the flow control; 6) NLI231 injected into a microcoil of 10% density without the flow control. The microcoils were delivered to the embolization site, and NLI231 was injected. After 1 h of observation, distal filters were collected, and grades of migration (I = none, II = partial, III = almost all-all) were assessed for each scenario. Embolization was achieved in scenarios with NLI231 and microcoils regardless of flow control (p < 0.01). NLI231 did not migrate in scenarios with microcoils and flow control (p < 0.05). NLI231 with microcoils without flow control can embolize the vessel, but partial migration occurred, and the distal distance of the NLI231 complex from the embolization site was longer (p < 0.01). Combining sparse coiling with NLI231 may be feasible but is limited to use when flow control is available, or where distal embolization is permissible to some extent.

Identifiants

pubmed: 39340741
doi: 10.1007/s11604-024-01667-4
pii: 10.1007/s11604-024-01667-4
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© 2024. The Author(s).

Références

Loffroy R, Desmyttere AS, Mouillot T, Pellegrinelli J, Facy O, Drouilllard A, Falvo N, Charles PE, Bardou M, Midulla M, Aho-Gléglé S, Chevallier O. Ten-year experience with arterial embolization for peptic ulcer bleeding: N-butyl cyanoacrylate glue versus other embolic agents. Eur Radiol. 2021;31(5):3015–26. https://doi.org/10.1007/s00330-020-07427-y . (Epub 2020 Oct 31 PMID: 33128601).
doi: 10.1007/s00330-020-07427-y pubmed: 33128601
Sugawara S, Arai Y, Sone M, Ishiguchi T, Kitagawa A, Aramaki T, Sato R, Morishita H, Takeuchi Y, Inaba Y. Phase II Trial of Transarterial embolization using an n-Butyl-2-Cyanoacrylate/Lipiodol mixture (JIVROSG-0802). Cardiovasc Intervent Radiol. 2019;42(4):534–41. https://doi.org/10.1007/s00270-018-2141-7 . (Epub 2018 Dec 6 PMID: 30523386).
doi: 10.1007/s00270-018-2141-7 pubmed: 30523386
Higashino N, Sonomura T, Fukuda K, Ikoma A, Okuhira R, Ueda S, Kawai N. Feasibility and safety of n-Butyl Cyanoacrylate-Lipiodol-Iopamidol as an alternative liquid embolic material. Cardiovasc Intervent Radiol. 2021;44(3):482–8. https://doi.org/10.1007/s00270-020-02681-5 . (Epub 2020 Nov 23 PMID: 33230651).
doi: 10.1007/s00270-020-02681-5 pubmed: 33230651
Fukuda K, Higashino N, Sonomura T, Okuhira R, Koike M, Ikoma A, Kawai N, Minamiguchi H. Determination of the optimal ratio and the relationship between viscosity and adhesion of n-Butyl Cyanoacrylate-Lipiodol-Iopamidol for balloon-assisted embolization of wide-neck aneurysms in swine. Cardiovasc Intervent Radiol. 2022;45(3):357–64. https://doi.org/10.1007/s00270-021-03055-1 . (Epub 2022 Jan 21 PMID: 35064286).
doi: 10.1007/s00270-021-03055-1 pubmed: 35064286
Ikoma A, Sonomura T, Higashino N, Fukuda K, Ihira H, Furotani H, Koike M, Sato H, Murata SI, Minamiguchi H. Feasibility of the glue-in-plug technique using a novel liquid embolic material in a swine model. J Vasc Interv Radiol. 2023;34(12):2233–9. https://doi.org/10.1016/j.jvir.2023.08.044 . (Epub 2023 Sep 9 PMID: 37678753).
doi: 10.1016/j.jvir.2023.08.044 pubmed: 37678753
Okuhira R, Higashino N, Sonomura T, Fukuda K, Koike M, Kamisako A, Tanaka R, Koyama T, Sato H, Ikoma A, Minamiguchi H. Balloon-assisted portal vein embolization using n-Butyl-2-Cyanoacrylate-Lipiodol-iopamidol mixture in swine: A comparison of 2 formulations. J Vasc Interv Radiol. 2023;10(23):00831.
Fukamatsu F, Sugiura K, Takekoshi D, Fukuzawa T, Oyama K, Tsukahara Y, Kurozumi M, Shimizu A, Fujinaga Y. A ruptured splenic artery aneurysm treated by transcatheter arterial embolization using n-butyl cyanoacrylate-Lipiodol-Iopamidol. Radiol Case Rep. 2023;18(7):2385–90. https://doi.org/10.1016/j.radcr.2023.04.005.PMID:37179814;PMCID:PMC10172629 .
doi: 10.1016/j.radcr.2023.04.005.PMID:37179814;PMCID:PMC10172629 pubmed: 37179814 pmcid: 10172629
Higashino N, Sonomura T, Ikoma A, Tamai K, Fukuda K, Kawai N, Minamiguchi H. Balloon-assisted arterial embolization of pseudoaneurysms using NBCA-Lipiodol-Iopamidol mixture in two clinical cases. Cardiovasc Intervent Radiol. 2024;47(2):268–70. https://doi.org/10.1007/s00270-023-03571-2 . (Epub 2023 Oct 24 PMID: 37875616).
doi: 10.1007/s00270-023-03571-2 pubmed: 37875616
Suga T, Akamatsu T, Kawamura Y, Saegusa H, Kajiyama M, Nakamura N, Takei M, Matsumoto A. Actual behaviour of N-butyl-2-cyanoacrylate (histoacryl) in a blood vessel: a model of the varix. Endoscopy. 2002;34(1):73–7. https://doi.org/10.1055/s-2002-19384 . (PMID: 11778133).
doi: 10.1055/s-2002-19384 pubmed: 11778133
Ishikawa M, Horikawa M, Yamagami T, Uchida BT, Awai K, Kaufman JA. Embolization of arteriovenous malformations: effect of flow control and composition of n-Butyl-2 cyanoacrylate and iodized oil mixtures with and without ethanol in an in vitro model. Radiology. 2016;279(3):910–6. https://doi.org/10.1148/radiol.2015142583 . (Epub 2015 Dec 19 PMID: 26690906).
doi: 10.1148/radiol.2015142583 pubmed: 26690906
Hayashi N, Takeuchi Y, Miura H, Arima Y, Toda M, Okamoto T, Asai S, Sakai K, Hirota T, Yamada K. Is the cessation of blood flow faster than the polymerization of an n-Butyl cyanoacrylate-lipiodol mixture? An in vitro phantom study. Cardiovasc Intervent Radiol. 2020;43(4):630–5. https://doi.org/10.1007/s00270-019-02393-5 . (Epub 2019 Dec 12 PMID: 31832724).
doi: 10.1007/s00270-019-02393-5 pubmed: 31832724
Hübner GH, Steudel N, Kleber G, Behrmann C, Lotterer E, Fleig WE. Hepatic arterial blood flow velocities: assessment by transcutaneous and intravascular Doppler sonography. J Hepatol. 2000;32(6):893–9. https://doi.org/10.1016/s0168-8278(00)80093-8 . (PMID: 10898309).
doi: 10.1016/s0168-8278(00)80093-8 pubmed: 10898309
Miller SR, Jernigan SR, Abraham RJ, Buckner GD. Comparison of bolus versus dual-syringe administration systems on glass yttrium-90 microsphere deposition in an in vitro microvascular hepatic tumor model. J Vasc Interv Radiol. 2023;34(1):11–20. https://doi.org/10.1016/j.jvir.2022.07.032 . (Epub 2022 Sep 13 PMID: 36108898).
doi: 10.1016/j.jvir.2022.07.032 pubmed: 36108898
Libicher M, Reichert V, Aleksic M, Brunkwall J, Lackner KJ, Gawenda M. Balloon occlusion of the celiac artery: a test for evaluation of collateral circulation prior endovascular coverage. Eur J Vasc Endovasc Surg. 2008;36(3):303–5. https://doi.org/10.1016/j.ejvs.2008.04.009 . (Epub 2008 Jun 3 PMID: 18524649).
doi: 10.1016/j.ejvs.2008.04.009 pubmed: 18524649
Mathis JM, Barr JD, Jungreis CA, Yonas H, Sekhar LN, Vincent D, Pentheny SL, Horton JA. Temporary balloon test occlusion of the internal carotid artery: experience in 500 cases. AJNR Am J Neuroradiol. 1995;16(4):749–54.
pubmed: 7611033 pmcid: 8332245
Li YJ, Barthès-Biesel D, Salsac AV. Polymerization kinetics of n-butyl cyanoacrylate glues used for vascular embolization. J Mech Behav Biomed Mater. 2017;69:307–17. https://doi.org/10.1016/j.jmbbm.2017.01.003 . (Epub 2017 Jan 3 PMID: 28131066).
doi: 10.1016/j.jmbbm.2017.01.003 pubmed: 28131066
Yasumoto T, Osuga K, Yamamoto H, Ono Y, Masada M, Mikami K, Kanamori D, Nakamura M, Tanaka K, Nakazawa T, Higashihara H, Maeda N, Tomiyama N. Long-term outcomes of coil packing for visceral aneurysms: correlation between packing density and incidence of coil compaction or recanalization. J Vasc Interv Radiol. 2013;24(12):1798–807. https://doi.org/10.1016/j.jvir.2013.04.030 . (Epub 2013 Jun 27 PMID: 23810652).
doi: 10.1016/j.jvir.2013.04.030 pubmed: 23810652
BlackSwan Vascular, Inc. Lava Liquid Embolic System – P220020. the U.S. Food and Drug Administration. 2023. https://www.fda.gov/medical-devices/recently-approved-devices/lava-liquid-embolic-system-p220020
Albadawi H, Altun I, Hu J, Zhang Z, Panda A, Kim HJ, Khademhosseini A, Oklu R. Nanocomposite hydrogel with tantalum microparticles for rapid endovascular hemostasis. Adv Sci (Weinh). 2020;8(1):2003327. https://doi.org/10.1002/advs.202003327.PMID:33437588;PMCID:PMC7788497 .
doi: 10.1002/advs.202003327.PMID:33437588;PMCID:PMC7788497 pubmed: 33437588 pmcid: 7788497
Wang BH, Boulton M, Lee DH, Pelz DM, Lownie SP. A systematic characterization of the factors influencing polymerization and dynamic behavior of n-butyl cyanoacrylate. J Neurointerv Surg. 2018;10(2):150–5. https://doi.org/10.1136/neurintsurg-2017-013009 . (Epub 2017 May 2 PMID: 28465402).
doi: 10.1136/neurintsurg-2017-013009 pubmed: 28465402
Takasawa C, Seiji K, Matsunaga K, Matsuhashi T, Ohta M, Shida S, Takase K, Takahashi S. Properties of N-butyl cyanoacrylate-iodized oil mixtures for arterial embolization: in vitro and in vivo experiments. J Vasc Interv Radiol. 2012;23(9):1215-1221.e1. https://doi.org/10.1016/j.jvir.2012.06.022 . (PMID: 22920981).
doi: 10.1016/j.jvir.2012.06.022 pubmed: 22920981

Auteurs

Takeshi Suzuki (T)

Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan. suzutake@shinshu-u.ac.jp.

Jun Matsuda (J)

Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.

Yoshinori Tsukahara (Y)

Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.

Ayumi Ohya (A)

Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.

Akira Yamada (A)

Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.

Masahiro Kurozumi (M)

Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.

Yasunari Fujinaga (Y)

Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, Nagano, 390-8621, Japan.

Classifications MeSH