Efficacy and safety of carbon fiber retrograde intramedullary nailing in tibio-talar-calcaneal fusion: a single-centre retrospective study.
Ankle fusion
Carbon fiber
Retrograde intramedullary nailing
Tibio-talar-calcaneal arthrodesis
Journal
Orthopaedics & traumatology, surgery & research : OTSR
ISSN: 1877-0568
Titre abrégé: Orthop Traumatol Surg Res
Pays: France
ID NLM: 101494830
Informations de publication
Date de publication:
03 Oct 2024
03 Oct 2024
Historique:
received:
27
03
2024
revised:
25
07
2024
accepted:
02
10
2024
medline:
6
10
2024
pubmed:
6
10
2024
entrez:
5
10
2024
Statut:
aheadofprint
Résumé
Tibio-talar-calcaneal (TTC) fusion is a salvage procedure designated for treating various severe hindfoot pathologies. While traditional methods have been effective, the advantage of carbon fiber (CF) retrograde intramedullary nailing (RIMN) presents a potentially superior technique. This study evaluates the efficacy and safety of CF RIMN in TTC fusion, focusing on union rates, complication rates, and patient-reported outcomes. Conducted as a single-center, retrospective study, this research involved 21 patients who underwent TTC with CF RIMN from 2015 to 2021. Patient selection excluded those with active infections or those needing significant bone allografts. Patient follow-up was conducted at multiple intervals postoperatively, with a minimum follow-up of 24 months, assessing for union complications and using tools like the VAS, SF12, and AOFAS for patient-reported outcomes. The study observed a 90% union rate among patients. Complication rates included a 14% incidence of iatrogenic fractures to the anterior tibial cortex and 19% postoperative complications. Significant improvement was noted in VAS scores but not in SF12 and AOFAS scores. The use of 200 mm RIMN was identified as requiring careful consideration due to associated complications. CF RIMN in TTC fusion demonstrates a high union rate with notable complications. The significant improvement in VAS scores indicates patient satisfaction, but the lack of statistical significance in SF12 and AOFAS scores warrants attention. The findings advocate for the cautious use of 200 mm RIMN and highlight the need for further research, suggesting prospective, multicenter studies to validate these findings and explore long-term outcomes. III.
Identifiants
pubmed: 39368703
pii: S1877-0568(24)00304-9
doi: 10.1016/j.otsr.2024.104018
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
104018Informations de copyright
Copyright © 2024 Elsevier Masson SAS. All rights reserved.