Effect of volumetric concentration factor on virus removal for low-pressure reverse osmosis membrane in drinking water production: A study on different scales.

Drinking water production Low-pressure reverse osmosis Scaling-up Virus concentration Virus removal

Journal

Water research
ISSN: 1879-2448
Titre abrégé: Water Res
Pays: England
ID NLM: 0105072

Informations de publication

Date de publication:
27 Sep 2024
Historique:
received: 06 12 2023
revised: 17 09 2024
accepted: 26 09 2024
medline: 7 10 2024
pubmed: 7 10 2024
entrez: 6 10 2024
Statut: aheadofprint

Résumé

Reverse osmosis membranes are intended to constitute a complete physical barrier against nanometric-sized pathogens such as enteric viruses. Literature describes that low-pressure reverse osmosis achieves high viral removal rates (above 5 log), surpassing those of ultrafiltration (1 to 3 log). However, these studies often used individual viruses and high feed viral concentrations (above 10

Identifiants

pubmed: 39369511
pii: S0043-1354(24)01435-0
doi: 10.1016/j.watres.2024.122536
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

122536

Informations de copyright

Copyright © 2024 The Author(s). Published by Elsevier Ltd.. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Hugo Taligrot (H)

Aix Marseille Univ., CNRS, Centrale Med., M2P2 UMR 7340, Equipe Procédés Membranaires (EPM), Europôle de l'Arbois, BP80, Pavillon Laennec, Hall C, 13545, Aix en Provence Cedex, France.

Sébastien Wurtzer (S)

Eau de Paris, Direction de la Recherche du Développement et de la Qualité de l'Eau, 33 Avenue Jean Jaurès, 94200, Ivry-Sur-Seine, France.

Mathias Monnot (M)

Aix Marseille Univ., CNRS, Centrale Med., M2P2 UMR 7340, Equipe Procédés Membranaires (EPM), Europôle de l'Arbois, BP80, Pavillon Laennec, Hall C, 13545, Aix en Provence Cedex, France.

Jacques Geslin (J)

Eau de Paris, Direction de la Recherche du Développement et de la Qualité de l'Eau, 33 Avenue Jean Jaurès, 94200, Ivry-Sur-Seine, France.

Laurent Moulin (L)

Eau de Paris, Direction de la Recherche du Développement et de la Qualité de l'Eau, 33 Avenue Jean Jaurès, 94200, Ivry-Sur-Seine, France.

Philippe Moulin (P)

Aix Marseille Univ., CNRS, Centrale Med., M2P2 UMR 7340, Equipe Procédés Membranaires (EPM), Europôle de l'Arbois, BP80, Pavillon Laennec, Hall C, 13545, Aix en Provence Cedex, France. Electronic address: philippe.moulin@univ-amu.fr.

Classifications MeSH