A comparative study of shade-matching performance using intraoral scanner, spectrophotometer, and visual assessment.


Journal

Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288

Informations de publication

Date de publication:
09 10 2024
Historique:
received: 12 07 2024
accepted: 25 09 2024
medline: 10 10 2024
pubmed: 10 10 2024
entrez: 9 10 2024
Statut: epublish

Résumé

This study aimed to explore the clinical applicability of the shade-matching function in intraoral scanners. This study measured the tooth colors of maxillary anterior dentitions of 83 adults using visual matching, a spectrophotometer, and a scanner according to two color systems: VITA Classical (VC) and VITA 3D-Master (V3D). Agreement between each method was assessed by weighted Cohen's kappa coefficient (K

Identifiants

pubmed: 39384854
doi: 10.1038/s41598-024-74354-z
pii: 10.1038/s41598-024-74354-z
doi:

Types de publication

Journal Article Comparative Study

Langues

eng

Sous-ensembles de citation

IM

Pagination

23640

Subventions

Organisme : Korean Government
ID : NRF-2022R1F1A1067929

Informations de copyright

© 2024. The Author(s).

Références

Tabatabaian, F., Beyabanaki, E., Alirezaei, P. & Epakchi, S. Visual and digital tooth shade selection methods, related effective factors and conditions, and their accuracy and precision: A literature review. J. Esthet. Restor. Dent. 33, 1084–1104. https://doi.org/10.1111/jerd.12816 (2021).
doi: 10.1111/jerd.12816 pubmed: 34498789
Morsy, N. & Holiel, A. A. Color difference for shade determination with visual and instrumental methods: A systematic review and meta-analysis. Syst. Rev. 12, 95. https://doi.org/10.1186/s13643-023-02263-9 (2023).
doi: 10.1186/s13643-023-02263-9 pubmed: 37291652 pmcid: 10249324
Alnusayri, M. O., Sghaireen, M. G., Mathew, M., Alzarea, B. & Bandela, V. Shade selection in esthetic dentistry: A review. Cureus. 14, e23331. https://doi.org/10.7759/cureus.23331 (2022).
doi: 10.7759/cureus.23331 pubmed: 35464532 pmcid: 9015060
Jouhar, R. et al. Analysis of shade-matching ability in dental students: A comparative study under clinical and correcting light conditions. BMC Med. Educ. 24. https://doi.org/10.1186/s12909-024-05146-2 (2024).
Parameswaran, V., Anilkumar, S., Lylajam, S., Rajesh, C. & Narayan, V. Comparison of accuracies of an intraoral spectrophotometer and conventional visual method for shade matching using two shade guide systems. J. Indian Prosthodont. Soc. 16, 352–358. https://doi.org/10.4103/0972-4052.176537 (2016).
doi: 10.4103/0972-4052.176537 pubmed: 27746599 pmcid: 5062144
Ebeid, K., Sabet, A., El Sergany, O. & Della Bona, A. Accuracy and repeatability of different intraoral instruments on shade determination compared to visual shade selection. J. Esthet. Restor. Dent.Bold">34, 988–993. https://doi.org/10.1111/jerd.12884 (2022).
doi: 10.1111/jerd.12884 pubmed: 35142422
Kim, H. K. Evaluation of the repeatability and matching accuracy between two identical intraoral spectrophotometers: An in vivo and in vitro study. J. Adv. Prosthodont. 10, 252–258. https://doi.org/10.4047/jap.2018.10.3.252 (2018).
doi: 10.4047/jap.2018.10.3.252 pubmed: 29930796 pmcid: 6004350
Kim, H. K. A study on the color distribution of natural teeth by age and gender in the Korean population with an intraoral spectrophotometer. J. Esthet. Restor. Dent. 30, 408–414. https://doi.org/10.1111/jerd.12424 (2018).
doi: 10.1111/jerd.12424 pubmed: 30267604
Shah, P. et al. Investigating working practices of dentists on shade taking: Evidence based good practice versus observed practice. J. Dent. 97, 103341. https://doi.org/10.1016/j.jdent.2020.103341 (2020).
doi: 10.1016/j.jdent.2020.103341 pubmed: 32348795
Mehl, A., Bosch, G., Fischer, C. & Ender, A. In vivo tooth-color measurement with a new 3D intraoral scanning system in comparison to conventional digital and visual color determination methods. Int. J. Comput. Dent. 20, 343–361 (2017).
pubmed: 29292410
Amornvit, P., Rokaya, D., Peampring, C. & Sanohkan, S. Confocal 3D optical intraoral scanners and comparison of image capturing accuracy. Comput. Mater. Contin. 66 https://doi.org/10.32604/cmc.2020.011943 (2021).
Shetty, S., Gali, S., Augustine, D. & Sv, S. Artificial intelligence systems in dental shade-matching: A systematic review. J. Prosthodont. https://doi.org/10.1111/jopr.13805 (2023).
doi: 10.1111/jopr.13805 pubmed: 37986239
Akl, M. A., Mansour, D. E. & Zheng, F. The role of Intraoral Scanners in the shade matching process: A systematic review. J. Prosthodont. 32, 196–203. https://doi.org/10.1111/jopr.13576 (2023).
doi: 10.1111/jopr.13576 pubmed: 35919949
Czigola, A. et al. Comparing the effectiveness of shade measurement by intraoral scanner, digital spectrophotometer, and visual shade assessment. J. Esthet. Restor. Dent. 33, 1166–1174. https://doi.org/10.1111/jerd.12810 (2021).
doi: 10.1111/jerd.12810 pubmed: 34397163
Floriani, F. et al. A comparative study of shade-matching reproducibility using an intraoral scanner and a spectrophotometer. Dent. J. (Basel). 12, 62. https://doi.org/10.3390/dj12030062 (2024).
doi: 10.3390/dj12030062 pubmed: 38534286
Rutkūnas, V., Dirsė, J. & Bilius, V. Accuracy of an intraoral digital scanner in tooth color determination. J. Prosthet. Dent. 123, 322–329. https://doi.org/10.1016/j.prosdent.2018.12.020 (2020).
doi: 10.1016/j.prosdent.2018.12.020 pubmed: 31227232
Huang, M. et al. Evaluation of accuracy and characteristics of tooth-color matching by intraoral scanners based on Munsell color system: An in vivo study. Odontology. 110, 759–768. https://doi.org/10.1007/s10266-022-00694-9 (2022).
doi: 10.1007/s10266-022-00694-9 pubmed: 35212853
McHugh, M. L. Interrater reliability: The kappa statistic. Biochem. Med. (Zagreb). 22, 276–282 (2012).
doi: 10.11613/BM.2012.031 pubmed: 23092060
Yoon, H. I. et al. A study on possibility of clinical application for color measurements of shade guides using an intraoral digital scanner. J. Prosthodont. 27, 670–675. https://doi.org/10.1111/jopr.12559 (2018).
doi: 10.1111/jopr.12559 pubmed: 29377326
Revilla-León, M., Methani, M. M. & Özcan, M. Impact of the ambient light illuminance conditions on the shade matching capabilities of an intraoral scanner. J. Esthet. Restor. Dent. 33, 906–912. https://doi.org/10.1111/jerd.12662 (2021).
doi: 10.1111/jerd.12662 pubmed: 32959520
Rao, D. & Joshi, S. Evaluation of natural tooth color space of the Indian population and its comparison to manufacturer’s shade systems. Contemp. Clin. Dent. 9, 395–399. https://doi.org/10.4103/ccd.ccd_144_18 (2018).
doi: 10.4103/ccd.ccd_144_18 pubmed: 30166833 pmcid: 6104365
Michou, S. et al. Automated caries detection in vivo using a 3D intraoral scanner. Sci. Rep. 11, 21276. https://doi.org/10.1038/s41598-021-00259-w (2021).
doi: 10.1038/s41598-021-00259-w pubmed: 34711853 pmcid: 8553860
Sirintawat, N., Leelaratrungruang, T., Poovarodom, P., Kiattavorncharoen, S. & Amornsettachai, P. The accuracy and reliability of tooth shade selection using different instrumental techniques: An in vitro study. Sensors (Basel). 21, 7490. https://doi.org/10.3390/s21227490 (2021).
doi: 10.3390/s21227490 pubmed: 34833565
Hampé-Kautz, V., Roman, T., Schwob, T., Cournault, B. & Etienne, O. In-vivo repeatability of three intra-oral spectrophotometers. J. Esthet. Restor. Dent. 36, 520–526. https://doi.org/10.1111/jerd.13182 (2024).
doi: 10.1111/jerd.13182 pubmed: 38168888
Yilmaz, B., Irmak, O. & Yaman, B. C. Outcomes of visual tooth shade selection performed by operators with different experience. J. Esthet. Restor. Dent. 31, 500–507. https://doi.org/10.1111/jerd.12507 (2019).
doi: 10.1111/jerd.12507 pubmed: 31228358
Özat, P. B., Tuncel, İ. & Eroğlu, E. Repeatability and reliability of human eye in visual shade selection. J. Oral Rehabil. 40, 958–964. https://doi.org/10.1111/joor.12103 (2013).
doi: 10.1111/joor.12103 pubmed: 24127905
Dozic, A., Kleverlaan, C. J., Aartman, I. H. & Feilzer, A. J. Relation in color of three regions of vital human incisors. Dent. Mater. 20, 832–838. https://doi.org/10.1016/j.dental.2003.10.013 (2004).
doi: 10.1016/j.dental.2003.10.013 pubmed: 15451238

Auteurs

Joo-Hyun Lee (JH)

Department of Perio-Prosthodontic Implantology, Graduate School of Clinical Dentistry, Ajou University, Suwon, Republic of Korea.

Hee-Kyung Kim (HK)

Department of Perio-Prosthodontic Implantology, Graduate School of Clinical Dentistry, Ajou University, Suwon, Republic of Korea. denthk@ajou.ac.kr.
Department of Prosthodontics, Institute of Oral Health Science, Ajou University School of Medicine, Suwon, Republic of Korea. denthk@ajou.ac.kr.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH