Safety and performance of the ultrathin sirolimus-eluting coronary stent in an all-comer patient population: the S-FLEX UK-II registry.
cardiology
cardiovascular disease
coronary intervention
Journal
BMJ open
ISSN: 2044-6055
Titre abrégé: BMJ Open
Pays: England
ID NLM: 101552874
Informations de publication
Date de publication:
22 Oct 2024
22 Oct 2024
Historique:
medline:
23
10
2024
pubmed:
23
10
2024
entrez:
22
10
2024
Statut:
epublish
Résumé
We evaluated the clinical safety and performance of the ultrathin strut biodegradable polymer-coated Supraflex Cruz (Sahajanand Medical TechnologiesLtd., Surat, India) sirolimus-eluting stent (SES) in an all-comer patient population requiring coronary stent implantation. The study was a prospective, observational, multicentre, single-arm registry. The study was conducted at 19 NHS Hospitals across the UK, from March 2020 to September 2021. A total of 1904 patients with symptomatic coronary artery disease (age ≥18 years) who underwent percutaneous coronary intervention with at least one Supraflex Cruz SES were enrolled. The primary endpoint was target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI) and clinically indicated target lesion revascularisation (CI-TLR), at 12 months. Safety endpoints were stent thrombosis, all-cause death and any MI. Prespecified subgroups analysis included patients with diabetes mellitus, bifurcation lesion, type B2/C lesion defined as per ACC/AHA (American College of Cardiology/American Heart Association) lesion classification and long coronary lesions (>20 mm). A total of 2973 Supraflex Cruz SES were implanted in 1835 patients (mean age: 65.20±11.03 years). Of these, 404 patients had diabetes mellitus (491 lesions), 271 had bifurcation lesions (293 lesions), 1541 had type B2/C lesions (1832 lesions) and 985 had long coronary lesions (>20 mm, 1139 lesions). Among the overall population, device success was achieved in 98.2% of lesions. TLF occurred in 12 (0.7%) patients (0.3% cardiac death, 0.2% TV-MI, 0.2% CI-TLR) at 30 days and in 43 (2.3%) patients (0.8% cardiac death, 0.8% TV-MI, 0.8% CI-TLR) at 12 months follow-up. The rate of definite stent thrombosis was 0.3% in the overall population at 12 months. The incidence of TLF and stent thrombosis was 6.2% and 1% in the diabetic, 1.8% and none in bifurcation lesion, 2.5% and 0.3% in type B2/C lesion, and 2.7% and 0.3% in long coronary lesions (>20 mm) subgroups, respectively. at 12 months follow-up. The S-FLEX UK-II registry confirms the clinical safety and performance of the ultrathin Supraflex Cruz SES in an all-comer population with complex coronary artery disease, demonstrating low rates of TLF and stent thrombosis. ISRCTN39751665 (https://doi.org/10.1186/ISRCTN39751665).
Identifiants
pubmed: 39438097
pii: bmjopen-2024-084028
doi: 10.1136/bmjopen-2024-084028
doi:
Substances chimiques
Sirolimus
W36ZG6FT64
Types de publication
Journal Article
Observational Study
Multicenter Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
e084028Informations de copyright
© Author(s) (or their employer(s)) 2024. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.
Déclaration de conflit d'intérêts
Competing interests: None declared.