Is cone-beam computed tomography more accurate than periapical radiography for detection of vertical root fractures? A systematic review and meta-analysis.
Cone-Beam Computed Tomography
Dental Digital Radiography
Tooth Fractures
Tooth Root
Journal
BMC medical imaging
ISSN: 1471-2342
Titre abrégé: BMC Med Imaging
Pays: England
ID NLM: 100968553
Informations de publication
Date de publication:
22 Oct 2024
22 Oct 2024
Historique:
received:
28
07
2024
accepted:
17
10
2024
medline:
23
10
2024
pubmed:
23
10
2024
entrez:
22
10
2024
Statut:
epublish
Résumé
This study aimed to conduct a systematic review and meta-analysis to summarize the available evidence comparing the diagnostic accuracy of periapical radiography (PA) and cone-beam computed tomography (CBCT) for detection of vertical root fractures (VRFs). A search was conducted in PubMed, Scopus, and Web of Science for articles published regarding all types of human teeth. Data were analyzed by Comprehensive Meta-Analysis statistical software V3 software program. The I2 statistic was applied to analyze heterogeneity among the studies. Twenty-three articles met the criteria for inclusion in the systematic review and 16 for the meta-analysis. The sensitivity and specificity for detection of VRFs were calculated to be 0.51 and 0.87, respectively for PA radiography, and 0.70 and 0.84, respectively for CBCT. The sensitivity of CBCT was higher than PA radiography; however, difference between the specificity of the two modalities was not statistically significant.
Sections du résumé
BACKGROUND
BACKGROUND
This study aimed to conduct a systematic review and meta-analysis to summarize the available evidence comparing the diagnostic accuracy of periapical radiography (PA) and cone-beam computed tomography (CBCT) for detection of vertical root fractures (VRFs).
METHODS
METHODS
A search was conducted in PubMed, Scopus, and Web of Science for articles published regarding all types of human teeth. Data were analyzed by Comprehensive Meta-Analysis statistical software V3 software program. The I2 statistic was applied to analyze heterogeneity among the studies.
RESULTS
RESULTS
Twenty-three articles met the criteria for inclusion in the systematic review and 16 for the meta-analysis. The sensitivity and specificity for detection of VRFs were calculated to be 0.51 and 0.87, respectively for PA radiography, and 0.70 and 0.84, respectively for CBCT.
CONCLUSIONS
CONCLUSIONS
The sensitivity of CBCT was higher than PA radiography; however, difference between the specificity of the two modalities was not statistically significant.
Identifiants
pubmed: 39438817
doi: 10.1186/s12880-024-01472-5
pii: 10.1186/s12880-024-01472-5
doi:
Types de publication
Journal Article
Systematic Review
Meta-Analysis
Comparative Study
Langues
eng
Sous-ensembles de citation
IM
Pagination
286Informations de copyright
© 2024. The Author(s).
Références
Uysal S, Akcicek G, Yalcin ED, Tuncel B, Dural S. The influence of voxel size and artifact reduction on the detection of vertical root fracture in endodontically treated teeth. Acta Odontol Scand. 2021;79(5):354–8.
pubmed: 33337942
doi: 10.1080/00016357.2020.1859611
Maddalone M, Gagliani M, Citterio CL, Karanxha L, Pellegatta A, Del Fabbro M. Prevalence of vertical root fractures in teeth planned for apical surgery. A retrospective cohort study. Int Endod J. 2018;51(9):969–74.
pubmed: 29478245
doi: 10.1111/iej.12910
Chai H, Tamse A. Vertical Root Fracture in Buccal Roots of Bifurcated Maxillary Premolars from Condensation of Gutta-percha. J Endod. 2018;44(7):1159–63.
pubmed: 29861061
doi: 10.1016/j.joen.2018.03.017
Tamse A. Vertical root fractures in endodontically treated teeth: diagnostic signs and clinical management. Endod Top. 2006;13(1):84–94.
doi: 10.1111/j.1601-1546.2006.00200.x
Khasnis SA, Kidiyoor KH, Patil AB, Kenganal SB. Vertical root fractures and their management. J Conserv Dent. 2014;17(2):103–10.
pubmed: 24778502
pmcid: 4001262
doi: 10.4103/0972-0707.128034
Lustig JP, Tamse A, Fuss Z. Pattern of bone resorption in vertically fractured, endodontically treated teeth. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000;90(2):224–7.
pubmed: 10936842
doi: 10.1067/moe.2000.107445
Fox A, Basrani B, Kishen A, Lam EWN. A Novel Method for Characterizing Beam Hardening Artifacts in Cone-beam Computed Tomographic Images. J Endod. 2018;44(5):869–74.
pubmed: 29571911
doi: 10.1016/j.joen.2018.02.005
Kositbowornchai S, Nuansakul R, Sikram S, Sinahawattana S, Saengmontri S. Root fracture detection: a comparison of direct digital radiography with conventional radiography. Dentomaxillofac Radiol. 2001;30(2):106–9.
pubmed: 11313731
doi: 10.1038/sj/dmfr/4600587
Salineiro FCS, Kobayashi-Velasco S, Braga MM, Cavalcanti MGP. Radiographic diagnosis of root fractures: a systematic review, meta-analyses and sources of heterogeneity. Dentomaxillofac Radiol. 2017;46(8):20170400.
pubmed: 28749700
pmcid: 5965946
doi: 10.1259/dmfr.20170400
Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am. 2008;52(4):707–30v.
pubmed: 18805225
doi: 10.1016/j.cden.2008.05.005
Scarfe WC, Farman AG, Levin MD, Gane D. Essentials of maxillofacial cone beam computed tomography. Alpha Omegan. 2010;103(2):62–7.
pubmed: 20645632
doi: 10.1016/j.aodf.2010.04.001
Chang E, Lam E, Shah P, Azarpazhooh A. Cone-beam Computed Tomography for Detecting Vertical Root Fractures in Endodontically Treated Teeth: A Systematic Review. J Endod. 2016;42(2):177–85.
pubmed: 26631300
doi: 10.1016/j.joen.2015.10.005
Freitas DQ, Vasconcelos TV, Noujeim M. Diagnosis of vertical root fracture in teeth close and distant to implant: an in vitro study to assess the influence of artifacts produced in cone beam computed tomography. Clin Oral Investig. 2019;23(3):1263–70.
pubmed: 29984377
doi: 10.1007/s00784-018-2558-z
Angelopoulos C, Scarfe WC, Farman AG. A comparison of maxillofacial CBCT and medical CT. Atlas Oral Maxillofac Surg Clin North Am. 2012;20(1):1–17.
pubmed: 22365427
doi: 10.1016/j.cxom.2011.12.008
Chavda R, Mannocci F, Andiappan M, Patel S. Comparing the in vivo diagnostic accuracy of digital periapical radiography with cone-beam computed tomography for the detection of vertical root fracture. J Endod. 2014;40(10):1524–9.
pubmed: 25154316
doi: 10.1016/j.joen.2014.05.011
da Silveira PF, Vizzotto MB, Liedke GS, da Silveira HL, Montagner F, da Silveira HE. Detection of vertical root fractures by conventional radiographic examination and cone beam computed tomography - an in vitro analysis. Dent Traumatol. 2013;29(1):41–6.
pubmed: 22413921
doi: 10.1111/j.1600-9657.2012.01126.x
Junqueira RB, Verner FS, Campos CN, Devito KL, do Carmo AMR. Detection of vertical root fractures in the presence of intracanal metallic post a comparison between periapical radiography and cone-beam computed tomography. J Endod. 2013;39(12):1620–4.
pubmed: 24238460
doi: 10.1016/j.joen.2013.08.031
Patel S, Brady E, Wilson R, Brown J, Mannocci F. The detection of vertical root fractures in root filled teeth with periapical radiographs and CBCT scans. Int Endod J. 2013;46(12):1140–52.
pubmed: 23617242
doi: 10.1111/iej.12109
Taghiloo H, Shokri H, Esmaeili F, Taghiloo S, Dehghani A-H, Rahbar M. Comparison of Digital Diagnostic Value and Cone Beam Computed Tomography (CBCT) in Determining Vertical Root Fracture in Single-Root Teeth. Pesquisa Brasileira em Odontopediatria e Clinica Integrada. 2018;18(1):10.
Hassan B, Metska ME, Ozok AR, van der Stelt P, Wesselink PR. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod. 2009;35(5):719–22.
pubmed: 19410091
doi: 10.1016/j.joen.2009.01.022
Bernardes RA, de Moraes IG, Húngaro Duarte MA, Azevedo BC, de Azevedo JR, Bramante CM. Use of cone-beam volumetric tomography in the diagnosis of root fractures. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;108(2):270–7.
pubmed: 19272806
doi: 10.1016/j.tripleo.2009.01.017
Kamburoğlu K, Murat S, Yüksel SP, Cebeci AR, Horasan S. Detection of vertical root fracture using cone-beam computerized tomography: an in vitro assessment. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010;109(2):e74–81.
pubmed: 20031454
doi: 10.1016/j.tripleo.2009.09.005
Varshosaz M, Tavakoli MA, Mostafavi M, Baghban AA. Comparison of conventional radiography with cone beam computed tomography for detection of vertical root fractures: an in vitro study. J Oral Sci. 2010;52(4):593–7.
pubmed: 21206162
doi: 10.2334/josnusd.52.593
Valiozadeh S, Khosravi M, Azizi Z. Diagnostic accuracy of conventional, digital and Cone Beam CT in vertical root fracture detection. Iranian Endodontic Journal. 2011;6(1):15–20.
Wang P, Yan XB, Lui DG, Zhang WL, Zhang Y, Ma XC. Detection of dental root fractures by using cone-beam computed tomography. Dentomaxillofac Radiol. 2011;40(5):290–8.
pubmed: 21697154
pmcid: 3520261
doi: 10.1259/dmfr/84907460
Khedmat S, Rouhi N, Drage N, Shokouhinejad N, Nekoofar MH. Evaluation of three imaging techniques for the detection of vertical root fractures in the absence and presence of gutta-percha root fillings. Int Endod J. 2012;45(11):1004–9.
pubmed: 22551491
doi: 10.1111/j.1365-2591.2012.02062.x
Kambungton J, Janhom A, Prapayasatok S, Pongsiriwet S. Assessment of vertical root fractures using three imaging modalities: cone beam CT, intraoral digital radiography and film. Dentomaxillofac Radiol. 2012;41(2):91–5.
pubmed: 22301636
pmcid: 3520378
doi: 10.1259/dmfr/49798768
Gunduz K, Avsever H, Orhan K, Çelenk P, Ozmen B, Cicek E, et al. Comparison of intraoral radiography and cone-beam computed tomography for the detection of vertical root fractures: an in vitro study. Oral Radiol. 2013;29:6–12.
doi: 10.1007/s11282-012-0098-9
Bechara B, McMahan CA, Noujeim M, Faddoul T, Moore WS, Teixeira FB, et al. Comparison of cone beam CT scans with enhanced photostimulated phosphor plate images in the detection of root fracture of endodontically treated teeth. Dentomaxillofac Radiol. 2013;42(7):20120404.
pubmed: 23625067
pmcid: 3699972
doi: 10.1259/dmfr.20120404
Brady E, Mannocci F, Brown J, Wilson R, Patel S. A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth. Int Endod J. 2014;47(8):735–46.
pubmed: 24182358
doi: 10.1111/iej.12209
Jakobson SJ, Westphalen VP, Silva Neto UX, Fariniuk LF, Schroeder AG, Carneiro E. The influence of metallic posts in the detection of vertical root fractures using different imaging examinations. Dentomaxillofac Radiol. 2014;43(1):20130287.
pubmed: 24191261
doi: 10.1259/dmfr.20130287
Takeshita WM, Iwaki LC, da Silva MC, Sabio S, Albino PR. Comparison of periapical radiography with cone beam computed tomography in the diagnosis of vertical root fractures in teeth with metallic post. J Conserv Dent. 2014;17(3):225–9.
pubmed: 24944444
pmcid: 4056392
doi: 10.4103/0972-0707.131781
Ezzodini Ardakani F, Razavi SH, Tabrizizadeh M. Diagnostic value of cone-beam computed tomography and periapical radiography in detection of vertical root fracture. Iran Endod J. 2015;10(2):122–6.
pubmed: 25834597
pmcid: 4372787
Abdinian M, Razavian H, Jenabi N. In vitro comparison of cone beam computed tomography with digital periapical radiography for detection of vertical root fracture in posterior teeth. J Dent. 2016;17(2):84.
Shaker IS, Mohamed NS, Abdelsamad AM. Effect of applying metal artifact reduction algorithm in cone beam computed tomography in detection of vertical root fractures of teeth with metallic post versus digital intraoral radiography. Saudi Endodontic Journal. 2019;9(1):51–5.
doi: 10.4103/sej.sej_56_18
Mizuhashi F, Ogura I, Sugawara Y, Oohashi M, Sekiguchi H, Saegusa H. Characteristics of root fractures: Image on intraoral radiography, panoramic radiography, and cone-beam computed tomography. Oral Science International. 2020;17(1):34–8.
doi: 10.1002/osi2.1037
Sha X, Jin L, Han J, Li Y, Zhang L, Qi S. Comparison between periapical radiography and cone beam computed tomography for the diagnosis of anterior maxillary trauma in children and adolescents. Dent Traumatol. 2022;38(1):62–70.
pubmed: 34275178
doi: 10.1111/edt.12706
Avsever H, Gunduz K, Orhan K, Uzun I, Ozmen B, Egrioglu E, et al. Comparison of intraoral radiography and cone-beam computed tomography for the detection of horizontal root fractures: an in vitro study. Clin Oral Investig. 2014;18(1):285–92.
pubmed: 23397452
doi: 10.1007/s00784-013-0940-4
Bornstein MM, Wölner-Hanssen AB, Sendi P, Von Arx T. Comparison of intraoral radiography and limited cone beam computed tomography for the assessment of root-fractured permanent teeth. Dent Traumatol. 2009;25(6):571–7.
pubmed: 19843131
doi: 10.1111/j.1600-9657.2009.00833.x
Talwar S, Utneja S, Nawal RR, Kaushik A, Srivastava D, Oberoy SS. Role of Cone-beam Computed Tomography in Diagnosis of Vertical Root Fractures: A Systematic Review and Meta-analysis. J Endod. 2016;42(1):12–24.
pubmed: 26699923
doi: 10.1016/j.joen.2015.09.012
Corbella S, Del Fabbro M, Tamse A, Rosen E, Tsesis I, Taschieri S. Cone beam computed tomography for the diagnosis of vertical root fractures: a systematic review of the literature and meta-analysis. Oral Surg Oral Med Oral Pathol Oral Radiol. 2014;118(5):593–602.
pubmed: 25442497
doi: 10.1016/j.oooo.2014.07.014
Nakata K, Naitoh M, Izumi M, Inamoto K, Ariji E, Nakamura H. Effectiveness of dental computed tomography in diagnostic imaging of periradicular lesion of each root of a multirooted tooth: a case report. J Endod. 2006;32(6):583–7.
pubmed: 16728257
doi: 10.1016/j.joen.2005.09.004
Tsai P, Torabinejad M, Rice D, Azevedo B. Accuracy of cone-beam computed tomography and periapical radiography in detecting small periapical lesions. J Endod. 2012;38(7):965–70.
pubmed: 22703662
doi: 10.1016/j.joen.2012.03.001
Edwards R, Altalibi M, Flores-Mir C. The frequency and nature of incidental findings in cone-beam computed tomographic scans of the head and neck region: a systematic review. J Am Dent Assoc. 2013;144(2):161–70.
pubmed: 23372132
doi: 10.14219/jada.archive.2013.0095
Schulze R, Heil U, Gross D, Bruellmann DD, Dranischnikow E, Schwanecke U, et al. Artefacts in CBCT: a review. Dentomaxillofac Radiol. 2011;40(5):265–73.
pubmed: 21697151
pmcid: 3520262
doi: 10.1259/dmfr/30642039
Byakova SF, Novozhilova NE, Makeeva IM, Grachev VI, Kasatkina IV. The detection of vertical root fractures in post-core restored teeth with cone-beam CT: in vivo and ex vivo. Dentomaxillofacial Radiology. 2019;48(6):20180327.
pubmed: 31095425
pmcid: 6747434
doi: 10.1259/dmfr.20180327
de Diniz Lima E, de Lira Farias Freitas AP, Mariz Suassuna FC, Sousa Melo SL, Bento PM, de Pita Melo D. Assessment of Cone-beam Computed Tomographic Artifacts from Different Intracanal Materials on Birooted Teeth. J Endod. 2019;45(2):209–13e2.
doi: 10.1016/j.joen.2018.11.007
Marinho Vieira LE, de Diniz Lima E, Peixoto LR, Oliveira Pinto MG, Sousa Melo SL, Oliveira ML, et al. Assessment of the Influence of Different Intracanal Materials on the Detection of Root Fracture in Birooted Teeth by Cone-beam Computed Tomography. J Endod. 2020;46(2):264–70.
pubmed: 31812360
doi: 10.1016/j.joen.2019.10.028
Hamidaddin A, Sarkis T, Lee R, Nummikoski P. A breath away from high resolution: patient movement during cone-beam computed tomography exposure. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology and Endodontology. 2007;2(103):e49.
doi: 10.1016/j.tripleo.2006.09.032
de Kinkelder R, Kalkman J, Faber DJ, Schraa O, Kok PHB, Verbraak FD, et al. Heartbeat-induced axial motion artifacts in optical coherence tomography measurements of the retina. Invest Ophthalmol Vis Sci. 2011;52(6):3908–13.
pubmed: 21467182
doi: 10.1167/iovs.10-6738
Shokri A, Eskandarloo A, Zahedi F, Karkehabadi H, Foroozandeh M, Farhadian M. Effect of different intracanal posts and exposure parameters on detection of vertical root fractures by cone-beam computed tomography. Aust Endod J. 2023;49(Suppl 1):132–45.
pubmed: 36269003
doi: 10.1111/aej.12700