New-generation single-layer PTFE-covered coronary stent for endovascular repair of iatrogenic arterial side-branch injury in non-coronary lesions for the RECOVER (REsults after percutaneous interventions with COVERed stents) Investigators.
Covered stent
PTFE
Vascular injury
Journal
Cardiovascular revascularization medicine : including molecular interventions
ISSN: 1878-0938
Titre abrégé: Cardiovasc Revasc Med
Pays: United States
ID NLM: 101238551
Informations de publication
Date de publication:
18 Oct 2024
18 Oct 2024
Historique:
received:
03
08
2024
revised:
25
09
2024
accepted:
26
09
2024
medline:
24
10
2024
pubmed:
24
10
2024
entrez:
23
10
2024
Statut:
aheadofprint
Résumé
The incidence of iatrogenic injuries in peripheral arteries is increasing due to the expanding opportunities of managing various cardiovascular diseases by means of percutaneous intervention. Thus, endovascular repair with implantation of covered stent (CS) after vascular injury is gaining importance as an alternative to open surgery. In cases of smaller side-branch injuries, stenting of the main vessel with subsequent exclusion and sealing of the side-branch is associated with unfavourable revascularization rates and unpredictable ischemic complications in the corresponding supply area. This study reports the procedural and clinical outcomes of patients with iatrogenic vascular side-branch injuries treated with coronary-CS directly at the site of injury. This is a retrospective, multicentre registry study, including 40 patients with acute iatrogenic injuries of arterial side-branches undergoing implantation of single-layer polytetrafluorethylene (PTFE)-CS at 3 different centres in Europe between June 2014 and June 2023. Endpoints were procedural success, death, target vessel reintervention (TVR), bleeding and the need for surgical conversion. A total of 40 patients underwent implantation of single-layer PTFE-CS in the lower (97.5 %) and the upper limbs (2.5 %). The most common mechanisms were injuries after punctures, caused by needle and/or sheath (80 %), balloon-dilations (7.5 %) and during/after non-cardiac surgery (7.5 %). Procedural success was achieved in all cases (100 %). The rate of in-hospital mortality was 7.5 %. The median duration of hospitalization after the CS procedure was 4 days [2; 5.3]. At a median follow-up of 202.5 days [97.3-711.8], 36 patients (90 %) were alive and main vessel patency was 100 %. There were no cases of TVRs, bleedings or surgical conversions. Access-site related complications occurred in 5 % of all cases. In this study, the use of new-generation single-layer PTFE-covered coronary stents in non-coronary side-branch lesions after iatrogenic arterial injury shows a high technical success rate and favourable clinical efficacy and safety.
Sections du résumé
BACKGROUND
BACKGROUND
The incidence of iatrogenic injuries in peripheral arteries is increasing due to the expanding opportunities of managing various cardiovascular diseases by means of percutaneous intervention. Thus, endovascular repair with implantation of covered stent (CS) after vascular injury is gaining importance as an alternative to open surgery. In cases of smaller side-branch injuries, stenting of the main vessel with subsequent exclusion and sealing of the side-branch is associated with unfavourable revascularization rates and unpredictable ischemic complications in the corresponding supply area.
OBJECTIVE
OBJECTIVE
This study reports the procedural and clinical outcomes of patients with iatrogenic vascular side-branch injuries treated with coronary-CS directly at the site of injury.
METHODS
METHODS
This is a retrospective, multicentre registry study, including 40 patients with acute iatrogenic injuries of arterial side-branches undergoing implantation of single-layer polytetrafluorethylene (PTFE)-CS at 3 different centres in Europe between June 2014 and June 2023. Endpoints were procedural success, death, target vessel reintervention (TVR), bleeding and the need for surgical conversion.
RESULTS
RESULTS
A total of 40 patients underwent implantation of single-layer PTFE-CS in the lower (97.5 %) and the upper limbs (2.5 %). The most common mechanisms were injuries after punctures, caused by needle and/or sheath (80 %), balloon-dilations (7.5 %) and during/after non-cardiac surgery (7.5 %). Procedural success was achieved in all cases (100 %). The rate of in-hospital mortality was 7.5 %. The median duration of hospitalization after the CS procedure was 4 days [2; 5.3]. At a median follow-up of 202.5 days [97.3-711.8], 36 patients (90 %) were alive and main vessel patency was 100 %. There were no cases of TVRs, bleedings or surgical conversions. Access-site related complications occurred in 5 % of all cases.
CONCLUSIONS
CONCLUSIONS
In this study, the use of new-generation single-layer PTFE-covered coronary stents in non-coronary side-branch lesions after iatrogenic arterial injury shows a high technical success rate and favourable clinical efficacy and safety.
Identifiants
pubmed: 39443255
pii: S1553-8389(24)00695-X
doi: 10.1016/j.carrev.2024.09.018
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 The Authors. Published by Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest MJ reports speaker fees from Biotronik, personal fees from Orbus Neich, grants and personal fees from Boston Scientific, grants and personal fees from Edwards, personal fees from AstraZeneca, personal fees from Recor, grants from Amgen, not related to the current work, HS reports honoraria from AstraZeneca, Bayer Vital, MSD Sharp & Dohme, Novartis, Servier, Sanofi-Aventis, Boehringer Ingelheim, Daiichi Sankyo, Amgen, Pfizer and consulting fees from AstraZeneca, Amgen, MSD Sharp & Dohme, not related to the current work; SK reports speaker and consulting fees from AstraZeneca, Bristol Myers Squibb, and Bentley and speaker fees from Abbott, Boehringer-Ingelheim and Translumina and a research grant from Bentley, all other authors report no conflict of interest.