Augmented reality guidance improves accuracy of orthopedic drilling procedures.


Journal

Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288

Informations de publication

Date de publication:
25 Oct 2024
Historique:
received: 10 09 2023
accepted: 10 10 2024
medline: 25 10 2024
pubmed: 25 10 2024
entrez: 25 10 2024
Statut: epublish

Résumé

In several orthopedic procedures, the accurate use of surgical power tools is critical to avoid damage to surrounding tissues. As such, various guidance techniques and safety measures were developed. Augmented reality (AR) guidance shows promise but requires validation. We evaluated a new approach using an inside-out infrared tracking solution for the HoloLens to compensate for its limited tracking performance. Eighteen participants with varying levels of experience (student, trainee, expert) each drilled twelve trajectories (six perpendicular, six oblique) in equidimensional wooden logs. Three different techniques were evaluated: freehand drilling; proprioception-guided drilling towards the contralateral index finger; and AR-guided drilling using a tracked drill and a virtual overlay of the log with predefined guidance vectors. The angular errors between planned and performed trajectories were compared using a mixed-design ANOVA. The results demonstrated that guidance technique (p < 0.001) and drilling direction (p < 0.001) significantly affected drilling accuracy, while experience (p = 0.75) did not. AR outperformed both other techniques, particularly for oblique trajectories (p < 0.001). For perpendicular trajectories, it only outperformed proprioception guidance (p = 0.04). Target plots revealed an important scatter perpendicular to the longitudinal axis of the log during freehand and proprioception-guided drilling, especially for oblique trajectories. This inaccuracy disappeared during AR-guided drilling. As such, we were able to conclude that AR guidance using inside-out infrared tracking reduced angular uncertainty during directional drilling, resulting in improved drilling accuracy. This improvement was particularly noticeable for complex trajectories and angles. The benefits of AR guidance were observed across all experience levels, highlighting its potential for orthopedic applications. We believe this study opens the way for the methodical evaluation of AR guidance in specific orthopedic use cases.

Identifiants

pubmed: 39448659
doi: 10.1038/s41598-024-76132-3
pii: 10.1038/s41598-024-76132-3
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

25269

Informations de copyright

© 2024. The Author(s).

Références

Dietze, S., Perka, C. & Baecker, H. Gefäß- und nervenverletzungen in der hüftendoprothetik. Orthopäde 43(1), 64–69. https://doi.org/10.1007/s00132-013-2126-9 (2014).
doi: 10.1007/s00132-013-2126-9 pubmed: 24384891
Abdul-Jabbar, A. et al. Neurovascular relationships of S2AI screw placement: Anatomic study. World Neurosurg. 116, e108–e112. https://doi.org/10.1016/j.wneu.2018.04.095 (2018).
doi: 10.1016/j.wneu.2018.04.095 pubmed: 29689397
Han, C. D. et al. Relationship between distal screws and femoral arteries in closed hip nailing on computed tomography angiography. Arch. Orthop. Trauma Surg. 133(3), 361–366. https://doi.org/10.1007/s00402-012-1674-5 (2013).
doi: 10.1007/s00402-012-1674-5 pubmed: 23271663
Iorio, J. A., Jakoi, A. M. & Rehman, S. Percutaneous sacroiliac screw fixation of the posterior pelvic ring. Orthop. Clin. N. Am. 46(4), 511–521. https://doi.org/10.1016/j.ocl.2015.06.005 (2015).
doi: 10.1016/j.ocl.2015.06.005
Robinson, L., Persico, F., Lorenz, E. & Seligson, D. Clavicular caution: an anatomic study of neurovascular structures. Injury 45(12), 1867–1869. https://doi.org/10.1016/j.injury.2014.08.031 (2014).
doi: 10.1016/j.injury.2014.08.031 pubmed: 25306887
Gertzbein, S. D. & Robbins, S. E. Accuracy of pedicular screw placement in vivo. Spine 15(1), 11–14. https://doi.org/10.1097/00007632-199001000-00004 (1990).
doi: 10.1097/00007632-199001000-00004 pubmed: 2326693
Langeveld, A. R. J., Rustenburg, C. M. E., Hoozemans, M. J. M., Burger, B. J. & Meuffels, D. E. To improve your surgical drilling skills, make use of your index fingers. Clin. Orthop. Relat. Res. 477(1), 232–239. https://doi.org/10.1097/corr.0000000000000557 (2019).
doi: 10.1097/corr.0000000000000557 pubmed: 30394951
Rankin, I., Rehman, H. & Frame, M. 3D-printed patient-specific ACL femoral tunnel guide from MRI. Open Orthop. J. 12, 59–68 (2018).
doi: 10.2174/1874325001812010059 pubmed: 29541271 pmcid: 5842381
Yang, J. C. et al. Clinical experience using a 3D-printed patient-specific instrument for medial opening wedge high tibial osteotomy. Biomed. Res. Int. 2018, 9246529. https://doi.org/10.1155/2018/9246529 (2018).
doi: 10.1155/2018/9246529 pubmed: 29854810 pmcid: 5964591
Marengo, N. et al. Cortical bone trajectory screw placement accuracy with a patient-matched 3-dimensional printed guide in lumbar spinal surgery: A clinical study. World Neurosurg. 130, e98-104. https://doi.org/10.1016/j.wneu.2019.05.241 (2019).
doi: 10.1016/j.wneu.2019.05.241 pubmed: 31307931
Audenaert, E. et al. A custom-made guide for femoral component positioning in hip resurfacing arthroplasty: Development and validation study. Comput. Aided Surg. 16(6), 304–309. https://doi.org/10.3109/10929088.2011.613951 (2011).
doi: 10.3109/10929088.2011.613951 pubmed: 21916560
Mezger, U., Jendrewski, C. & Bartels, M. Navigation in surgery. Langenbecks Arch. Surg. 398(4), 501–514. https://doi.org/10.1007/s00423-013-1059-4 (2013).
doi: 10.1007/s00423-013-1059-4 pubmed: 23430289 pmcid: 3627858
Kumar, V., Patel, S., Baburaj, V., Rajnish, R. K. & Aggarwal, S. Does robotic-assisted surgery improve outcomes of total hip arthroplasty compared to manual technique? A systematic review and meta-analysis. Postgrad. Med. J. 99(1171), 375–383. https://doi.org/10.1136/postgradmedj-2021-141135 (2023).
doi: 10.1136/postgradmedj-2021-141135 pubmed: 37294729
Luengo-Matos, S. et al. Efficacy and safety of robotic spine surgery: Systematic review and meta-analysis. J. Orthop. Traumatol. 23(1), 49. https://doi.org/10.1186/s10195-022-00669-0 (2022).
doi: 10.1186/s10195-022-00669-0 pubmed: 36242652 pmcid: 9569281
Wang, H. et al. Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: A pilot study. Int. Orthop. 40(9), 1941–1947. https://doi.org/10.1007/s00264-015-3028-8 (2016).
doi: 10.1007/s00264-015-3028-8 pubmed: 26572882
Ogawa, H., Hasegawa, S., Tsukada, S. & Matsubara, M. A pilot study of augmented reality technology applied to the acetabular cup placement during total hip arthroplasty. J. Arthroplasty 33(6), 1833–1837. https://doi.org/10.1016/j.arth.2018.01.067 (2018).
doi: 10.1016/j.arth.2018.01.067 pubmed: 29502961
Liu, H., Auvinet, E., Giles, J. & Baena, R. Y. Augmented reality based navigation for computer assisted hip resurfacing: A proof of concept study. Ann. Biomed. Eng. 46(10), 1595–1605. https://doi.org/10.1007/s10439-018-2055-1 (2018).
doi: 10.1007/s10439-018-2055-1 pubmed: 29796955 pmcid: 6153979
Frantz, T., Jansen, B., Duerinck, J. & Vandemeulebroucke, J. Augmenting Microsoft’s HoloLens with vuforia tracking for neuronavigation. Healthc. Technol. Lett. 5(5), 221–225 (2018).
doi: 10.1049/htl.2018.5079 pubmed: 30464854 pmcid: 6222243
Van Gestel, F. et al. Augmented reality-assisted neurosurgical drain placement (ARANED): Technical note. Acta Neurochir. Suppl. 131, 267–273. https://doi.org/10.1007/978-3-030-59436-7_50 (2021).
doi: 10.1007/978-3-030-59436-7_50 pubmed: 33839856
Van Gestel, F. et al. The effect of augmented reality on the accuracy and learning curve of external ventricular drain placement. Neurosurg. Focus 51(2), E8. https://doi.org/10.3171/2021.5.focus21215 (2021).
doi: 10.3171/2021.5.focus21215 pubmed: 34333479
Frantz, T., Jansen, B., Vandemeulebroucke, J., Van Gestel, F., Duerinck, J., & Scheerlinck, T. An augmented reality system, an augmented reality HMD, an augmented reality method and a computer program. Belgium; WO2022144116A1 (2022).
Van Gestel, F. et al. Neuro-oncological augmented reality planning for intracranial tumor resection. Front. Neurol. 14, 1104571. https://doi.org/10.3389/fneur.2023.1104571 (2023).
doi: 10.3389/fneur.2023.1104571 pubmed: 36998774 pmcid: 10043492
Schneider, M. et al. Augmented reality-assisted ventriculostomy. Neurosurg. Focus 50(1), E16. https://doi.org/10.3171/2020.10.focus20779 (2021).
doi: 10.3171/2020.10.focus20779 pubmed: 33386016
van Doormaal, T. P. C., van Doormaal, J. A. M. & Mensink, T. Clinical accuracy of holographic navigation using point-based registration on augmented-reality glasses. Oper. Neurosurg. (Hagerstown) 17(6), 588–593. https://doi.org/10.1093/ons/opz094 (2019).
doi: 10.1093/ons/opz094 pubmed: 31081883
Fick, T., van Doormaal, J. A. M., Hoving, E. W., Regli, L. & van Doormaal, T. P. C. Holographic patient tracking after bed movement for augmented reality neuronavigation using a head-mounted display. Acta Neurochir. (Wien) 163(4), 879–884. https://doi.org/10.1007/s00701-021-04707-4 (2021).
doi: 10.1007/s00701-021-04707-4 pubmed: 33515122
Felix, B. et al. Augmented reality spine surgery navigation: increasing pedicle screw insertion accuracy for both open and minimally invasive spine surgeries. Spine 47(12), 865–872. https://doi.org/10.1097/BRS.0000000000004338 (2022).
doi: 10.1097/BRS.0000000000004338 pubmed: 35132049
Kriechling, P. et al. Augmented reality through head-mounted display for navigation of baseplate component placement in reverse total shoulder arthroplasty: A cadaveric study. Arch. Orthop. Trauma Surg. 143(1), 169–175. https://doi.org/10.1007/s00402-021-04025-5 (2023).
doi: 10.1007/s00402-021-04025-5 pubmed: 34213578
Kurosaka, K. et al. Does augmented reality-based portable navigation improve the accuracy of cup placement in THA compared with accelerometer-based portable navigation? A randomized controlled trial. Clin. Orthop. Relat. Res. 481(8), 1515–1523. https://doi.org/10.1097/CORR.0000000000002602 (2023).
doi: 10.1097/CORR.0000000000002602 pubmed: 36862072 pmcid: 10344563
Kunz, C. et al. Infrared marker tracking with the HoloLens for neurosurgical interventions. Curr. Dir. Biomed. Eng. 6(1), 20200027. https://doi.org/10.1515/cdbme-2020-0027 (2020).
doi: 10.1515/cdbme-2020-0027
Gsaxner, C., Li, J., Pepe, A., Schmalstieg, D., & Egger, J. Inside-out instrument tracking for surgical navigation in augmented reality. In Proceedings of the 27th ACM Symposium on Virtual Reality Software and Technology (VRST '21). Association for Computing Machinery, New York, NY, USA, Article 4, 1–11 (2021). https://doi.org/10.1145/3489849.3489863
Martin-Gomez, A. et al. STTAR: Surgical tool tracking using off-the-shelf augmented reality head-mounted displays. IEEE Trans. Vis. Comput. Graph https://doi.org/10.1109/TVCG.2023.3238309 (2023).
doi: 10.1109/TVCG.2023.3238309 pubmed: 37788205
Azimi, E., Qian, L., Navab, N., & Kazanzides, P. Alignment of the Virtual Scene to the Tracking Space of a Mixed Reality Head-Mounted Display (2019). arXiv:1703.05834 https://doi.org/10.48550/arXiv.1703.05834
Moise, E. E. Arcs of Circles. In Elementary Geometry from an Advanced Standpoint 2nd edn 192–197 (Addison Wesley Publishing Company, 1974).
Akaike, H. A new look at the statistical model identification. IEEE Trans. Autom. Control 19(6), 716–723. https://doi.org/10.1109/TAC.1974.1100705 (1974).
doi: 10.1109/TAC.1974.1100705
Neuville, Q., Scheerlinck, T., & Duerinck, J. Current status and future perspectives for augmented reality navigation in neurosurgery and orthopedic surgery. In P Boulanger (Ed.). Applications of Augmented Reality - Current State of the Art. United Kingdom: IntechOpen (2023). https://doi.org/10.5772/intechopen.1002344
Wolf, J. et al. How different augmented reality visualizations for drilling affect trajectory deviation, visual attention, and user experience. Int. J. Comput. Assist. Radiol. Surg. 18(8), 1363–1371. https://doi.org/10.1007/s11548-022-02819-5 (2023).
doi: 10.1007/s11548-022-02819-5 pubmed: 36808552 pmcid: 10363038
Seibold, M., Spirig, J. M., Esfandiari, H., Farshad, M. & Fürnstahl, P. Translation of medical AR research into clinical practice. J. Imaging. 9(2), 44. https://doi.org/10.3390/jimaging9020044 (2023).
doi: 10.3390/jimaging9020044 pubmed: 36826963 pmcid: 9961816

Auteurs

Frederick Van Gestel (F)

Department of Neurosurgery, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090, Brussels, Belgium. frederick.vangestel@uzbrussel.be.
Research Group Center For Neurosciences (C4N-NEUR), Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, 1090, Brussels, Belgium. frederick.vangestel@uzbrussel.be.

Fiene Van Aerschot (F)

Department of Orthopedic Surgery and Traumatology, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090, Brussels, Belgium.
Research Group Beeldvorming en Fysische Wetenschappen (BEFY-ORTHO), Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, 1090, Brussels, Belgium.

Taylor Frantz (T)

Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 9, 1050, Brussels, Belgium.
imec, Kapeldreef 75, 3001, Leuven, Belgium.

Anouk Verhellen (A)

imec, Kapeldreef 75, 3001, Leuven, Belgium.
Department of Studies on Media, Innovation and Technology (SMIT), Vrije Universiteit Brussel (VUB), Pleinlaan 9, 1050, Brussels, Belgium.

Kurt Barbé (K)

Department of Public Health, Research Group Biostatistics and Medical Informatics (BISI), Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, 1090, Brussels, Belgium.

Bart Jansen (B)

Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 9, 1050, Brussels, Belgium.
imec, Kapeldreef 75, 3001, Leuven, Belgium.

Jef Vandemeulebroucke (J)

Department of Electronics and Informatics (ETRO), Vrije Universiteit Brussel (VUB), Pleinlaan 9, 1050, Brussels, Belgium.
imec, Kapeldreef 75, 3001, Leuven, Belgium.
Department of Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium.

Johnny Duerinck (J)

Department of Neurosurgery, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090, Brussels, Belgium.
Research Group Center For Neurosciences (C4N-NEUR), Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, 1090, Brussels, Belgium.

Thierry Scheerlinck (T)

Department of Orthopedic Surgery and Traumatology, Universitair Ziekenhuis Brussel (UZ Brussel), Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090, Brussels, Belgium.
Research Group Beeldvorming en Fysische Wetenschappen (BEFY-ORTHO), Vrije Universiteit Brussel (VUB), Laarbeeklaan 103, 1090, Brussels, Belgium.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH