Diagnostic Value of Anti-HTLV-1-Antibody Quantification in Cerebrospinal Fluid for HTLV-1-Associated Myelopathy.
Humans
Paraparesis, Tropical Spastic
/ diagnosis
Human T-lymphotropic virus 1
/ immunology
Male
Female
Middle Aged
Sensitivity and Specificity
Adult
Aged
HTLV-I Antibodies
/ cerebrospinal fluid
ROC Curve
HTLV-I Infections
/ diagnosis
Reagent Kits, Diagnostic
Neopterin
/ cerebrospinal fluid
Chemokine CXCL10
/ cerebrospinal fluid
HTLV-1-associated myelopathy
anti-HTLV-1 antibody
cerebrospinal fluid
diagnosis
human T-cell leukemia virus type 1
Journal
Viruses
ISSN: 1999-4915
Titre abrégé: Viruses
Pays: Switzerland
ID NLM: 101509722
Informations de publication
Date de publication:
08 Oct 2024
08 Oct 2024
Historique:
received:
15
09
2024
revised:
05
10
2024
accepted:
07
10
2024
medline:
26
10
2024
pubmed:
26
10
2024
entrez:
26
10
2024
Statut:
epublish
Résumé
The diagnostic accuracy of cerebrospinal fluid (CSF) anti-human T-cell leukemia virus type I (HTLV-1) antibody testing for HTLV-1-associated myelopathy/tropical spastic paraparesis (HAM) remains unclear. Therefore, we measured the anti-HTLV-1 antibody levels in CSF using various test kits, evaluated the stability of CSF antibodies, and performed a correlation analysis using the particle agglutination (PA) method, as well as a receiver operating characteristic (ROC) analysis between patients with HAM and carriers. The CSF anti-HTLV-1 antibody levels were influenced by freeze-thaw cycles but remained stable when the CSF was refrigerated at 4 °C for up to 48 h. Measurements from 92 patients (69 patients with HAM and 23 carriers) demonstrated a strong correlation (r > 0.9) with the PA method across all six quantifiable test kits. All six test kits, along with CSF neopterin and CXCL10, exhibited areas under the ROC curve greater than 0.9, indicating a high diagnostic performance for HAM. Among these, five test kits, Lumipulse and Lumipulse Presto HTLV-I/II, HISCL-UD (a kit under development), HTLV-Abbott, and Elecsys HTLV-I/II, established a cutoff with 100% sensitivity and maximum specificity, achieving a sensitivity of 100% and a specificity ranging from 43.5% to 56.5%. This cutoff value, in combination with clinical findings, will aid in the accurate diagnosis of HAM.
Identifiants
pubmed: 39459915
pii: v16101581
doi: 10.3390/v16101581
pii:
doi:
Substances chimiques
HTLV-I Antibodies
0
Reagent Kits, Diagnostic
0
Neopterin
670-65-5
Chemokine CXCL10
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Health and Labour Sciences Research Grant on Rare and Intractable Diseases from the Ministry of Health, Labour and Welfare of Japan
ID : 22FC1013
Organisme : Practical Research Project for Rare/Intractable Diseases of the Japan Agency for Medical Research and Development
ID : JP22fk0108124, JP23ek0109529, and JP24ek0109735