Division of Ophthalmology, School of Medicine, VISSUM Alicante, Universidad Miguel Hernández, Calle Cabañal 1, 03016, Alicante, Spain. jlalio@vissum.com.
Cornea, Cataract and Refractive Surgery Department, VISSUM Corporation, Alicante, Spain. jlalio@vissum.com.
Publications dans "Lentilles intraoculaires multifocales" :
The purpose of this study was to investigate and compare the optical performance of five trifocal intraocular lenses (IOLs) following the ISO 11979-2 standards, analysing the impact of tilt and decent...
Extended depth of focus (EDOF) and multifocal (Multi) intraocular lenses (IOL) can provide a fixed distance of near vision, which may result in some discomfort for patients who prefer different near d...
A total of 100 eyes were implanted with Tecnis ZXR00, ZMB00 or ZCB00 IOLs. Uncorrected distance, intermediate, and near visual acuity (UDVA, UIVA, and UNVA, respectively), corrected distance visual ac...
At 3 months postoperative, the EDOF and Multi groups showed non-inferiority compared to the Mono group in the UDVA (P > 0.05) and CDVA (P > 0.05) but superiority in the UNVA (P < 0.001). The UIVA was ...
The EDOF and Multi IOLs achieved excellent visual quality and superior UNVA compared to the Mono IOL, but the CNDVA was significantly inferior to the UNVA. Patients' near visual experience can be effe...
To analyze and compare the visual performance and patient satisfaction following the implantation of toric multifocal intraocular lenses (TMIOLs) in adult patients with different types of developmenta...
This is a prospective observational cohort study. Patients diagnosed with DC aged 18-30 years were divided into three groups according to the anatomic location of the lens opacity: cortical, nuclear, ...
Fifty-five eyes of 37 patients were enrolled and completed a 1-year follow-up. The mean CA was 2.06 ± 0.79 D preoperatively, and the mean RA was 0.29 ± 0.30 D 3-month postoperatively. The IOL rotation...
In adult patients with DC accompanied by CA, TMIOLs implantation achieved good postoperative visual outcomes and significantly reduced glasses dependency. Patients with cortical or nuclear lens opacit...
To evaluate the optical performance and safety of a new multifocal lens with a novel optical design featuring two additional foci (or intensifiers) in patients with cataract and presbyopia....
In this single-center, non-randomized prospective observational study, 31 patients underwent implantation of the new multifocal IOL between March 2020 and November 2021 at a tertiary clinical center i...
Of the 31 patients who underwent implantation of the new IOL, 30 underwent bilateral surgery (61 eyes in total). At 3 months, all 61 eyes had an uncorrected distance visual acuity (UCDVA) of at least ...
The new multifocal IOL with a novel optical concept (5 foci) showed a wide range of visual acuity especially at intermediate and near distances in patients undergoing cataract surgery. Uncorrected vis...
Cataract, defined as an opacity of the lens in one or both eyes, is the leading cause of blindness worldwide. Cataract may initially be treated with new spectacles, but often surgery is required, whic...
To compare visual outcomes after implantation of trifocal intraocular lenses (IOLs) to those of extended depth of focus (EDOF) IOLs. To produce a brief economic commentary summarising recent economic ...
We searched CENTRAL (which contains the Cochrane Eyes and Vision Trials Register), MEDLINE, Embase, and three trial registries on 15 June 2022. For our economic evaluation, we also searched MEDLINE an...
We included studies comparing trifocal and EDOF IOLs in adults undergoing cataract surgery. We did not include studies involving people receiving IOLs for correction of refractive error alone (or refr...
We used standard Cochrane methods. Two review authors working independently selected studies for inclusion and extracted data from the reports. We assessed the risk of bias in the studies, and we asse...
We included five studies that compared trifocal and EDOF lenses in people undergoing cataract surgery. Three trifocal lenses (AcrySof IQ PanOptix, ATLISA Tri 839MP, FineVision Micro F) and one EDOF le...
Distance visual acuity after cataract surgery may be similar whether the lenses implanted are trifocal IOLs or EDOF (TECNIS Symfony) IOLs. People receiving trifocal IOLs may achieve better near vision...
To compare the clinical and aberrometric outcomes obtained with a new diffractive pentafocal intraocular lens (IOL) and a diffractive trifocal IOL....
Patients bilaterally implanted with the pentafocal Intensity SeeLens IOL (Hanita Lenses) (n = 30) and the trifocal FineVision POD F IOL (PhysIOL) (n = 30) during cataract surgery were studied after 1 ...
Distance and near visual acuities were similar with the two IOLs, but distance-corrected intermediate visual acuity was better with the Intensity IOLs (0.03 ± 0.04 vs 0.11 ± 0.04 logMAR in the FineVis...
In this comparative series, the pentafocal Intensity IOL provided better intermediate vision and better defocus curve than the FineVision IOL, with comparable distance and near vision. The optical dis...
To evaluate the feasibility of creating flanges using an optic piercing technique with a 6 - 0 polypropylene monofilament for scleral fixation of dislocated one-piece diffractive multifocal intraocula...
Experimental study and case series....
Optical bench test and eyes with IOL dislocation....
Two separate 6 - 0 polypropylenes were penetrated twice at the opposite peripheral optic of the TECNIS Synergy IOL (Johnson & Johnson Vision). The root mean square of the modulation transfer function ...
The optical bench test showed no differences in MTF...
The four-flanged polypropylene optic piercing technique for multifocal IOL scleral fixation can provide excellent clinical outcomes and IOL stability after surgery without diminishing the performance ...
This study aimed to observe the tilt and decentration of multifocal intraocular lens (IOL) with optic capture in Berger space within 2 years after pediatric cataract surgery....
This is a prospective observational study. The implantation of multifocal IOL (Tecnis ZMB00) with optic capture in Berger space was performed on 33 patients (48 eyes) with pediatric cataract at Qingda...
All the multifocal IOLs were successfully implanted in Berger space with optic capture and no visually significant complications were detected during the follow-up. The mean tilt of IOLs was 2.779° ± ...
The follow-up results suggest the tilt and decentration of multifocal IOL implantation with optic capture in Berger space remain stable in an acceptable range within 2 years after cataract surgery in ...
The study was approved by the Ethics Committee of Qingdao Eye Hospital, and registered on Chinese Clinical Trial Registry (ChiCTR identifier: 1900023155)....
To discuss factors influencing corneal aberrations that might influence the optical quality after intraocular lens (IOL) implantation....
PubMed and Scopus were the main resources used to search the medical literature. An extensive search was performed to identify relevant articles concerning factors influencing the level of corneal abe...
Conclusive evidence is lacking regarding the correlation between age and changes in corneal aberrations. Patients with astigmatism have greater corneal higher-order aberrations than those with minimal...
Several factors influence the level of corneal higher-order aberrations. Multifocal and extended depth-of-focus IOLs can share similarities in their optical properties, and the main difference arises ...
The purpose of the study is to evaluate the visual and patient-reported outcomes of patients undergoing cataract surgery with implantation of an extended depth of focus (EDOF) intraocular lens (IOL) w...
Retrospective analysis of data from 30 eyes (23 patients) undergoing cataract surgery with implantation of one of two EDOF IOLs (follow-up: 37.9 ± 16.2 months) and prospective observational study incl...
In the retrospective phase, significant improvements were found in uncorrected distance (UDVA), corrected distance (CDVA), and corrected near visual acuity (CNVA) (...
EDOF IOLs seem to be a viable option for providing an efficient visual rehabilitation with good levels of patient satisfaction and spectacle independence associated in patients that are not primarily ...