Obstetrical haemorrhage is a potentially preventable cause of maternal morbidity and mortality; and measurements of surgical blood loss (BL) are often inaccurate. Accurate BL estimation is paramount a...
A total of 60 pregnant patients at term undergoing elective caesarean section under spinal anaesthesia were enrolled into the study. In the theatre, the patients' haemoglobin level was determined befo...
The mean visually estimated BL (EBL) and HemoCue calculated BL (CBL) were 470 ± 221 ml and 563 ± 204 ml, respectively (P = 0.125). The bias (mean difference between both methods) was negligible (45.25...
This study showed that visually EBL was closely related to HemoCue CBL when the quantity of BL was <500 ml....
The objective of this work was to carry out a systematic review of clinical practice guidelines (CPGs) pertaining to intraoperative red blood cell (RBC) transfusions, in terms of indications, decision...
RBC transfusions are common during surgery and there is evidence of wide variability in practice....
Major electronic databases (MEDLINE, EMBASE, and CINAHL), guideline clearinghouses and Google Scholar were systematically searched from inception to January 2019 for CPGs pertaining to indications for...
Ten guidelines published between 1992 and 2018 provided indications for intraoperative transfusions. No guideline addressed intraoperative transfusion decision-making as its primary focus. Six guideli...
This review has identified several clinical practice guidelines providing recommendations for intraoperative transfusion. The existing guidelines were noted to be highly variable in their recommendati...
Blood transfusions in the operating room are associated with increased morbidity and mortality as well as increased cost. The technology exists for continuous noninvasive hemoglobin monitoring (SpHb),...
To determine if a single versus a split equivalent daily dose of elemental iron was superior for hemoglobin mass (Hbmass) gains at altitude while minimizing gastrointestinal (GI) discomfort....
Twenty-four elite runners attended a 3.1 ± 0.3 wk training camp (Flagstaff, AZ; 2106 m). A two-group design, randomized and stratified to baseline Hbmass, sex, and ferritin (>30 μ·L), was implemented ...
Both conditions increased Hbmass from baseline (P < 0.05), with SINGLE (867.3 ± 47.9 g) significantly higher than SPLIT (828.9 ± 48.9 g) (P = 0.048). The GI scores were worse in SINGLE for weeks 1 and...
A single nightly 200-mg dose of elemental iron was superior to a split dose for optimizing Hbmass changes at altitude in runners over an approximately 3-wk training camp....
The effect of menstrual blood loss on oxygen-carrying capacity remains equivocal. The purpose of this study was to determine the effect of menstrual blood loss on hemoglobin mass in young, healthy wom...
Twenty-one women (age, 23 ± 6 yr; height, 168 ± 7 cm; weight, 66.1 ± 12.6 kg) with regular menstrual cycles, either using (n = 10) or not using oral contraceptives, participated in the study. Hemoglob...
Visits for women not using oral contraceptives were performed in the early follicular phase (3 ± 1 d after the onset of menses), late follicular phase (1 ± 1 d after the surge of luteinizing hormone i...
Menstrual blood loss had no measurable effect on hemoglobin mass in eumenorrheic women. However, oral contraceptive use resulted in a greater oxygen-carrying capacity, potentially leading to a greater...
Visual estimation and gravimetric methods are commonly used to quantify the volume of blood loss during cesarean delivery (CD). However, the correlation between blood loss and post-CD hemoglobin (Hb) ...
After obtaining Institutional Review Board approval, we performed a prospective study of 61 women undergoing CD to assess the relations between post-CD Hb and blood loss measured using 4 modalities: g...
The mean (standard deviation) preoperative Hb was 12 (1.1) g/dL and post-CD Hb was 11.3 (1.0) g/dL. Median (interquartile range) values for gBL, oBL, aBL, and tBL were 672 mL (266-970), 700 mL (600-80...
Given that we observed only weak correlations between each modality with post-CD Hb and no significant differences in the magnitude of the correlations across the 4 modalities, there may be limited cl...
We compared the accuracy of 3 point-of-care testing (POCT) devices with central laboratory measurements and the extent to which between-method disagreements could influence decisions to transfuse bloo...
Hemoglobin concentrations [Hb] were measured in 58 adult patients undergoing cardiothoracic surgery using 2 Ilex GEM Premier 3500 blood gas analyzers (BG_A and BG_B) and a HemoCue Hb-201 device (HemoC...
The 70 Lab[Hb] measurements ranged from 5.8 to 16.7 g/dL, of which 25 (36%) were <10.0 g/dL. Measurements by all 4 devices numbered 57. Mean POCT measurements did not differ significantly (P > .99). R...
All 3 POCT devices underestimated the Lab[Hb] and cannot be used interchangeably with standard laboratory measurements. BG_A and BG_B can be considered to be acceptably interchangeable with each other...
Studies of organ dysfunction in children are limited by a lack of consensus around organ dysfunction criteria....
To derive evidence-informed, consensus-based criteria for hematologic dysfunction in critically ill children....
Data sources included PubMed and Embase from January 1992 to January 2020....
Studies were included if they evaluated assessment/scoring tools to screen for hematologic dysfunction and assessed outcomes of mortality, functional status, organ-specific outcomes, or other patient-...
Data were abstracted from each eligible study into a standard data extraction form along with risk of bias assessment....
Twenty-nine studies were included. The systematic review supports the following criteria for hematologic dysfunction: thrombocytopenia (platelet count <100000 cells/µL in patients without hematologic ...
Most studies evaluated pre-specified thresholds of cytopenias. No studies addressed associations between the etiology or progression of cytopenias overtime with outcomes, and no studies evaluated cell...
Hematologic dysfunction, as defined by cytopenia, is a risk factor for poor outcome in critically ill children, although specific threshold values associated with increased mortality are poorly define...
This study tested the hypothesis that autologous blood transfusion (ABT) of ~50% of the red blood cells (RBC) from a standard 450-mL phlebotomy would increase mean power in a cycling time trial. In ad...
In a randomized, double-blind, placebo-controlled crossover design (3-month wash-out), nine highly trained male subjects donated two 450-mL blood bags each (BT trial) or were sham phlebotomized (PLA t...
The mean power was increased in time trials from before to after transfusion (P < 0.05) in BT (213 ± 35 vs 223 ± 38 W; mean ± SD) but not in PLA (223 ± 42 vs 224 ± 46 W). In contrast, the mean power o...
ABT of only ~135 mL of RBC is sufficient to increase mean power in a 650-kcal cycling time trial by ~5% in highly trained men. In contrast, a combined high-volume transfusion of ~135 and ~235 mL of RB...
Although many factors may interfere with hemoglobin (Hb)A1c measurement, Hb variants are among the most important factors....
We tested the HbA1c levels of the patient, a 32 year old Manchu Chinese woman, during a routine health check. We used different methods, including high-performance liquid chromatography (HPLC) and cap...
We discovered that our patient, who had an HbA1c value of 0, also has an Hb variant, Hb Long Island, which we found during the HbA1c analysis as part of her routine health check at the Health Manageme...
When there is no correlation between the clinical signs, glycemic status, and glycated Hb levels of the patient, the chromatogram of HbA1c should be carefully checked to detect possible variants that ...