Color imaging is a tried and true method for the evaluation of cosmetic and dermatological effects, but it fails to capture all the information in a scene's spectral reflectance. For this reason, ther...
We developed a novel HyperSpectral Imager (HSI) able to take in vivo full-face format images as a next generation instrument for skin color measurement and beyond. Here, we report part of the results ...
We find that the measurements from the HSI provide repeatability and reproducibility as good or better than those of our previous benchmark devices....
From these results, we conclude that not only is the HSI suitable for use in color evaluation studies, but also that it gives operational advantages over the previous generation of evaluation instrume...
Stakeholders in the modeling and simulation (M&S) community organized a workshop at the 2019 Annual Meeting of the Orthopaedic Research Society (ORS) entitled "Reproducibility in Modeling and Simulati...
Although high-resolution manometry (HR_ARM) is commonly used to diagnose defecatory disorders, its intraindividual day-to-day reproducibility is unknown. Since these measurements entail voluntary effo...
In 22 healthy women (35 years [14] mean [SD]) and 53 constipated patients (42 years [13], 46 women), the rectal balloon expulsion time (BET), and anorectal pressures were measured with HR_ARM on 2 day...
Among constipated patients, the anal resting (mean CCC [95%CI] 0.62 [0.43-0.76]) and squeeze pressures (CCC 0.65 [0.47-0.79]), rectoanal gradient during evacuation (CCC 0.42 [0.17-0.62]), and rectal s...
While HR_ARM variables and the BET are reproducible within healthy and constipated persons, the outcome on repeat testing differed in 79% of constipated patients....
Incorporating open science practices has become a priority for submission criteria in the International Journal of Eating Disorders (IJED). In this systematic review, we used the rigor and reproducibi...
For this systematic review, six trained coders examined 1145 articles published from January 2011 to May 2021, including the 5 years prior to the 2016 introduction of the Open Science Foundation artic...
There was evidence of a significant positive relationship between time and total rigor and reproducibility (Total RR) criteria included in IJED articles following the implementation of preregistration...
Although findings indicate that statistical rigor and reproducibility in this field has increased, the lack of direct relationship between open science methods and article visibility for scientists su...
Statistical controversies within science threaten the rigor and reproducibility of published research. Open science practices, including the preregistration of study hypotheses, links to statistical c...
To evaluate multicenter repeatability and reproducibility of T...
MRF experiments were performed on 5 different 3 Tesla MRI scanners at 3 different institutions: University Hospitals Cleveland Medical Center (Cleveland, OH), Brigham and Women's Hospital (Boston, MA)...
The intrascanner variation of values measured using MRF was less than 2% for T...
Prostate MRF measurements of T...
Western blot is a popular biomolecular analysis method for measuring the relative quantities of independent proteins in complex biological samples. However, variability in quantitative western blot da...
This study aimed to validate a semiquantitative electronic food frequency questionnaire (eFFQ) in estimating the intake of a comprehensive list of nutrients and bioactive compounds among adults from s...
Publicly available speech corpora facilitate reproducible research by providing open-access data for participants who have consented/assented to data sharing among different research teams. Such corpo...
In this research note, we introduce the PERCEPT (Perceptual Error Rating for the Clinical Evaluation of Phonetic Targets) corpora, PERCEPT-R (Rhotics) and PERCEPT-GFTA (Goldman-Fristoe Test of Articul...
We demonstrate the use of PERCEPT corpora, PhonBank, and Phon for clinical training and research questions appropriate to child citation speech. Increased use of these tools has the potential to enhan...
There is reason to believe that the favorable measurement properties of the 6‑minute walk test (6MWT) reported for retest reliability and its capability to detect a true change in healthy individuals ...
Immediately before postacute rehabilitation, 50 LuTXr completed 6MWT testing twice, separated by 1-2 workdays (retest reliability), and were reassessed after completion of rehabilitation 2 months late...
Baseline retest 6‑minute walk distance (6MWD) and the age-related predicted walking distance (6MWD%...
The 6MWT overall represents a reliable functional performance tool in LuTXr that is sensitive to detect changes in physical performance as a result of medical postacute rehabilitation....
Artificial intelligence (AI) algorithms hold the potential to revolutionize radiology. However, a significant portion of the published literature lacks transparency and reproducibility, which hampers ...