Departamento de Ciencias Básicas de la Salud, Facultad de Ciencias de la Salud, Universidad Rey Juan Carlos, Alcorcón, Spain.
Unidad Asociada al Instituto de Química Medica (IQM) del Consejo Superior de Investigaciones Científicas (CSIC), Universidad Rey Juan Carlos, Alcorcón, Spain.
High Performance Research Group in Experimental Pharmacology (Pharmakom-URJC), URJC, Alcorcón, Spain.
Departamento de Ciencias Básicas de la Salud, Facultad de Ciencias de la Salud, Universidad Rey Juan Carlos, Alcorcón, Spain.
Unidad Asociada al Instituto de Química Medica (IQM) del Consejo Superior de Investigaciones Científicas (CSIC), Universidad Rey Juan Carlos, Alcorcón, Spain.
High Performance Research Group in Experimental Pharmacology (Pharmakom-URJC), URJC, Alcorcón, Spain.
Department of Psychiatry, The Second Xiangya Hospital, Central South University, Changsha, Hunan 410011, China; Mental Health Institute of the Second Xiangya Hospital, Central South University, Chinese National Clinical Research Center on Mental Disorders (xiangya), Chinese National Technology Institute on Mental Disorders, Hunan Key Laboratory of Psychiatry and Mental Health, Changsha, Hunan 410011, China.
Suction cannula (SC) is an important instrument for a neurosurgeon. Currently used suction control valves, kept in the sterile field, are controlled by the surgeon, for which he needs to leave the sur...
Seven SC with various diameters of their lumen and TH were used for the study. Suction pressures were measured with suction tip open, immersed in saline and TH open and closed. TH of 2 SC were made sm...
Pressure and diameter of ST or TH were related in opposite direction. As the diameter increases the pressure decreases. A strong negative association was observed between the diameter of TH and the pr...
TH diameter of SC is important to control suction pressure with any size of SC. One should use tear-drop type TH or appropriate diameter of the circular type of TH to contemplate safe microneurosurger...
The principles of chest drainage have not changed significantly since 1875 when Bülau introduced the idea of underwater drainage tube which became a trademark of thoracic surgery. We performed a prosp...
A multi-center, prospective, parallel group, randomized, controlled trial enrolling patients after thoracic procedures in which visceral pleura remained intact at the end of surgery between August 202...
During the study period, 111 patients were recruited. Eleven patients had negative Suction-seal test and were excluded by inserting a traditional underwater seal. The remaining 100 patients were rando...
The results of this study suggest that either omitting drain or inserting a low auto suction drain safely substitutes the one-way valve when the visceral pleura remains intact. Omitting drain or inser...
Suction pressure is one of the most important factors influencing the amount of tissue obtained during endoscopic ultrasound-guided fine-needle aspiration/biopsy (EUS-FNA/FNB). In this study we aimed ...
Different types of fine needles and suction techniques were used, including the slow pull technique (SPT), dry suction technique (DST), wet suction technique (WST), neutralizing negative pressure tech...
Actual suction pressure and weight of the suctioning liquid were lower using SPT than using DST, while they were higher when using WST compared with those using DST. In general, the actual suction pre...
WST is superior to SPT and DST in terms of actual suction pressure and weight of suctioning liquid. Diameter of the FNA needle was an important factor that may affect the actual suction pressure and w...
Surgery, by nature, involves blood loss. Thus, suction plays an important role in ensuring a clean operating view and ease of access. In ophthalmology, there is a void for an efficient and flexible su...
Blood loss is common during surgical procedures, especially in open cardiac surgery. Allogenic blood transfusion is associated with increased morbidity and mortality. Blood conservation programs in ca...
We evaluated magnetic resonance imaging (MRI) as a qualitative tool for detection of turbulence. MRI is sensitive to flow; this study uses velocity-compensated T1-weighted 3D MRI for turbulence detect...
Our standard control suction head Model A showed pronounced signs of turbulence at all flow rates measured, while turbulence was only detectable in our modified Models 1-3 at higher flow rates (Models...
The comparison of flow performance of surgical suction heads with different geometries via acceleration-sensitized 3D MRI revealed significant differences in turbulence development between our standar...
The glenoid labrum acts as a bumper, deepening glenoid concavity and amplifying the concavity-compression mechanism, and serves as the scapular attachment for glenohumeral ligaments. The role of the p...
Fourteen fresh-frozen cadaveric shoulders were tested on a custom stability ratio measurement apparatus. The peak force that was required to translate the humeral head in anterior, anteroinferior, pos...
The suction cup effect was usually present with the intact labrum and always disappeared after removal of the labrum for anterior (100% vs. 0%) and posterior (86% vs. 0%) translations (P < .001). Afte...
Anteroinferior labral tears decreased posterior stability and posterosuperior labral tears decreased anterior and anteroinferior stability, largely because of loss of the suction cup effect....
To observe the characteristics of suction loss in small-incision lenticule extraction (SMILE) and analyze the factors affecting the stability of the suction ring, classify and grade suction loss, and ...
This study enrolled patients who underwent SMILE between June 2014 and June 2017. The relationship between the stability of the suction ring and suction loss was ascertained using surgical records and...
Suction loss can be divided into sudden and progressive types. According to the severity, the latter was divided into three grades (grade 1A or 1B, 2 and 3). Of the 1200 eyes (608 patients), two (0.17...
Progressive suction loss was the most frequently observed suction loss during SMILE procedure. Grading suction loss can elucidate its underlying mechanism, which can guide targeted intervention measur...
As the global community begins recovering from the COVID-19 pandemic, the challenges due to its aftermath remain. This health crisis has highlighted challenges associated with airborne pathogens and t...
This paper presents a novel suction device designed to counteract the spread of aerosols and droplets and be cost-effective and adaptable to diverse environments. We also conducted an experimental stu...
The device reduced airborne disease transmission risk, as evidenced by its capacity to decrease the half-life of aerosol volume from 23.6 minutes to 15.6 minutes, effectively capturing aerosol-sized d...
The experiment's findings confirm the suction device's capability to effectively remove droplets from the environment, making it a vital tool in enhancing indoor air quality. Given the sustained perfo...
To study the biometric modifications of the eyeball during suction in Laser assisted in Situ Keratomileusis (LASIK)....
Observational and cross-sectional study. We studied 43 patients who underwent surgery for myopia and myopic astigmatism. Mean age was 38.3 ± 11.5 years, and 19 were female (44.2%). Conventional LASIK ...
The mean spherical equivalent refractive error was -4.5 ± 2.3 diopters. During suction, the AQD did not change significantly (p = 0.231). However, AXL and VCL increased by 0.12 mm and 0.22 mm respecti...
Suction maneuvres during LASIK surgery produce changes of little magnitude in the eye globe, mainly a decrease in LT and an increase in VCL and AXL. Therefore, these modifications are expected to prod...