Clinical practice guidelines on intrapartum cardiotocography (CTG) interpretation provide structured tools to detect fetal hypoxia. Despite frequent use of different guidelines, little is known about ...
To compare existing intrapartum CTG interpretation guidelines....
We searched PubMed, CINAHL, Cochrane, Embase, guideline databases and websites of guideline development institutions using terms 'cardiotocography', 'electronic fetal/foetal monitoring', and 'guidelin...
Nineteen studies were considered for full review, and 13 met inclusion criteria. Two reviewers independently assessed guideline quality using the AGREE II instrument, and synthesised consensus and non...
There are significant differences between key intrapartum CTG interpretation guidelines currently being used. Greater consistency is needed across CTG interpretation guidelines to improve the quality ...
In many countries, the healthcare sector is dealing with important challenges such as increased demand for healthcare services, capacity problems in hospitals and rising healthcare costs. Therefore, o...
A budget impact analysis was conducted to estimate the actual costs and reimbursement of aCTG performed in midwife-led care and obstetrician-led care (ie, base-case analysis) from the Dutch healthcare...
Shifting aCTG from obstetrician-led care to midwife-led-care would increase actual costs with €311 763 (97.5% CI €188 574 to €426 072) and €1 247 052 (97.5% CI €754 296 to €1 704 290) for implementati...
From the Dutch healthcare perspective, we estimated that implementing aCTG in midwife-led care may increase the associated actual costs. At the same time, it might lower the healthcare reimbursement....
To compare diagnostic values of four intrapartum cardiotocography (CTG) classifications in predicting neonatal acidemia at birth....
Retrospective case-control study. Forty-three CTG traces with an umbilical artery pH < 7.00 (study group) and 43 traces with a pH ≥ 7.00 (control group) were analyzed. Inclusion criteria were singleto...
FIGO, RCOG, and NICHD classifications predicted neonatal acidemia with areas under the ROC curves (AUC) of 0.73, 95% confidence interval (CI) 0.63-0.84; 0.72, 95% CI 0.60-0.83; and 0.69, 95% CI 0.57-0...
The 5-tier classification system proposed by Parer and Ikeda for assessing CTG in labour was superior to FIGO, RCOG, and NICHD intrapartum CTG classifications in predicting severe neonatal acidemia at...
New guidelines for the interpretation of cardiotocography (CTG) have been presented by FIGO in 2015 (FIGO-15) and by NICE in 2017 (NICE-17) and 2022 (NICE-22) In Sweden, a previous template from 2009 ...
This is a historical cohort study including singleton births in Lund November 2015-February 2016, after spontaneous or induced labor at ≥34 completed gestational weeks with validated umbilical cord ac...
SWE-09 and NICE-22 had significantly higher sensitivity (both 92%; 95% CI 79-98%) than NICE-17 (68%; 51-82%), FIGO-15 (42%; 26-59%) and SWE-17 (39%; 24-57%) to identify neonates with acidemia by the c...
Current CTG interpretation templates either have low sensitivity to identify fetal acidemia or low specificity. Among current guidelines, NICE 2022 had the highest sensitivity to identify neonates wit...
Cardiotocography is defined as the recording of fetal heart rate and uterine contractions and is widely used during labor as a screening tool to determine fetal wellbeing. The visual interpretation of...
Admission cardiotocography (CTG), a noninvasive procedure, is used to indicate the state of oxygenation of the fetus on admission into the labor ward....
This study assessed the association of admission CTG findings with neonatal outcome at a tertiary health facility....
A prospective, observational study of 206 pregnant women who were admitted into the labor ward with singleton live pregnancies. Information on the demographic characteristics, obstetrics and medical h...
The admission CTG findings were normal in 73.3%, suspicious in 13.6%, and pathological in 13.1% of the women. The occurrence of low birth weight, special care baby unit (SCBU) admission, asphyxiated n...
Admission CTG was effective in identifying fetuses with a higher incidence of perinatal asphyxia. Neonatal outcome such as low birth weight, APGAR score, SCBU admission, and prolonged hospital admissi...
This study uses convolutional neural networks (CNNs) and cardiotocography data for the real-time classification of fetal status in the mobile application of a pregnant woman and the computer server of...
Modern technological advancements have made it possible to perform cardiotocography at home. Home-based management of high-risk pregnancies using a mobile cardiotocography system has been reported; ho...
The authors conducted a single-center, retrospective case series of patients with FGR. Seventeen women diagnosed with FGR were enrolled. Patients performed iCTG for 1 hour twice daily to examine their...
The median and minimum compliance rates were 93.33 (interquartile range [IQR], 70.00-100.00) and 40.7, respectively. The median and minimum validity rates were 100.00 (IQR, 90.48-100.00) and 36.4, res...
Even when the fetal prognosis is good, careful pre-evaluation is required before initiating home care management. The current study shows that the economic burden of hospitalization for patients can b...
Cardiotocography (CTG) applicability to improve fetal outcomes remains controversial. This study aimed to determine the clinically optimal CTG assessment duration using the integrated score index to p...
Intelligent cardiotocography (CTG) classification can assist obstetricians in evaluating fetal health. However, high classification performance is often achieved by complex machine learning (ML)-based...
Aiming to improve CTG classification performance and prediction interpretability, a hybrid model was proposed using a stacked ensemble strategy with mixed features and Kernel SHapley Additive exPlanat...
For intelligent CTG classification using 10-fold cross-validation, the accuracy and average F1 score were 0.9539 and 0.9249 in the public dataset, respectively; and those were 0.9201 and 0.8926 in the...
The proposed model has high classification performance and reasonable interpretability for intelligent fetal monitoring....