Department of Prosthodontics and Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul 03080, Korea.
Department of Prosthodontics and Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul 03080, Korea.
Department of Prosthodontics and Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, 101 Daehak-ro, Jongno-gu, Seoul 03080, Korea.
Institute of Materials Science and Engineering, Faculty of Mechanical Engineering, Lodz University of Technology, B. Stefanowskiego 1/15, 90-537 Lodz, Poland.
Institute of Materials Science and Engineering, Faculty of Mechanical Engineering, Lodz University of Technology, B. Stefanowskiego 1/15, 90-537 Lodz, Poland.
Institute of Materials Science and Engineering, Faculty of Mechanical Engineering, Lodz University of Technology, B. Stefanowskiego 1/15, 90-537 Lodz, Poland.
Division of Dental Technology, Department of Biomedical Sciences, University of West Attica, Athens, Greece, Phone: +30 2106848640, e-mail: agal@uniwa.gr agal@teiath.gr.
Department of Prosthetic Dentistry, University Hospital Heidelberg, University of Heidelberg, Im Neuenheimer Feld 400, 69120, Heidelberg, Germany. wolfgang.boemicke@med.uni-heidelberg.de.
Metal-ceramic restorations made from cobalt chromium (Co-Cr) alloy have been increasing, but studies on the effects of different manufacturing techniques on metal-ceramic interface characteristics and...
The purpose of this in vitro study was to examine the metal-ceramic interface and the metal-ceramic bond strength of a Co-Cr alloy produced by casting, milling, and selective laser melting (SLM) with ...
Co-Cr alloys were prepared by casting, milling, and SLM. Two different SLM devices were used. Ninety-six specimens (25×3×0.5 mm) were manufactured. The structure of the oxidation surface of Co-Cr spec...
The main effect of the interactions of the testing condition and manufacturing method variables on the bond strength variable was not statistically significantly different. No significant differences ...
The bond strength between Co-Cr alloy and ceramic is affected by the manufacturing method. The metal-ceramic bond strength is independent of thermal cycling. The bond strength value in all groups was ...
Dental cobalt-chromium (Co-Cr) alloy manufactured by selective laser melting (SLM) is not recommended for clinical applications before annealing because of excessive residual stress. However, limited ...
The purpose of this in vitro study was to investigate the effects of annealing temperature on the metal-ceramic bond properties of SLM Co-Cr alloys....
Four groups with different annealing temperatures (850 °C; 950 °C; 1050 °C; 1150 °C) were prepared by using SLM techniques. Bond strengths were measured by using a 3-point bend test; subsequently, deb...
The mean ±standard deviation values of the metal-ceramic bond strengths were 40.68 ±4.34 MPa for the 850 °C group, 37.54 ±5.34 MPa for the 950 °C group, 45.97 ±2.18 MPa for the 1050 °C group, and 50.7...
Annealing temperatures affected the metal-ceramic bond strengths of SLM Co-Cr porcelain specimens. 1150 °C annealing SLM Co-Cr specimens displayed higher bond strengths and improved fracture and inter...
Ceramic-sintering affects bond strength and longevity of metal-ceramic. This study investigated the effect of sintering temperatures and times on metal-ceramic bond strength vis-a-vis interfacial frac...
One hundred eighty rectangular-shaped (25 × 8 × 1 mm) casting (Auriloy® (CA)) and CAD-milling (Ceramill Sintron® (MA)) alloys were prepared and randomly veneered with ceramic at normal (930 °C; (TN)),...
Significant differences in G due to the effect of alloy, sintering temperature, and time (p < 0.05) were indicated. MA revealed higher G than CA. Raising temperatures enabled increasing G for CA, not ...
Bond strength was influenced by alloy, sintering temperature, and time. Ceramic has better adhesion to MA than CA. Enhancing bond for CA was succeeded through increasing sintering temperature and time...
MA offers stronger bond than CA. Enhancing bond is suggested by extended sintering. Raising temperature can enhance bond for CA, not for MA....
The aim of the present study is to investigate the metal-ceramic bond strength as a result of three different surface treatment methods: (1) oxidation, (2) oxidation and sandblasting, and (3) double o...
A total of 72 metal substrates were made from two different types of metal-ceramic alloys (...
For group I, the materials with oxidation based on the specifications, show mean value of 64.02 Nt. The oxidation and sandblasting materials have mean 55.92 Nt. The double oxidation materials have mea...
The best method of treatment of the metal substrate is specification oxidation, in terms of the strength of the metal-ceramic bond. Further treatment of the metal substrate reduces the strength of the...
A prerequisite for clinical success of metal-ceramic prosthetic restorations is the increased strength of the bond between ceramic material and metal substrate. With that in mind, the present research...
Reusing the powder in selective laser melting machines after multiple cycles is a cost-effective procedure for dental laboratories. However, information on the metal-ceramic bond strength of the frame...
The purpose of this in vitro study was to investigate how the bonding agent and repeated alloy powder reuse affected the metal-ceramic bond strength of cobalt chromium frameworks fabricated by using s...
Four square and 40-bar-shaped cobalt chromium frameworks were fabricated by selective laser melting. Half were produced by using virgin alloy powder (Group V; n...
Mean ±standard deviation bond strengths did not differ significantly (P>.05) between Groups V (31.25 ±4.65) and R (30.88 ±4.78). Group W (35.34 ±1.78) had significantly higher bond strength than Group...
Metal-ceramic bond strength was unaffected by alloy powder reuse. However, the bonding agent brand may affect the bond strength of cobalt chromium frameworks fabricated by using selective laser meltin...
Cobalt chromium (Co-Cr) alloys possess beneficial mechanical properties because alloys, even in thin sections, can resist high mastication forces and exhibit an acceptable bond to the surface porcelai...
This in vitro study investigates the hardness, yield strength, elastic modulus, and microstructure of the most commonly used Co-Cr alloys for fixed prosthodontics based on manufacturing technique. In ...
Five Co-Cr alloys were included (dumbbell and rectangular shaped) based on four manufacturing techniques: cast, milled, laser melted, and presintered milled. Commercially pure titanium grade 4 and tit...
The mechanical properties depend on the manufacturing technique used; the laser-melted and presintered Co-Cr specimens demonstrated the highest mechanical properties, followed by the milled and cast g...
The laser melting and presintered milling techniques produced higher mechanical properties compared with the cast and milled Co-Cr. These findings were confirmed through microstructural analysis with ...
The durability of dental restorations is highly determined by an accurate marginal fit, which is in turn affected by the high temperature of porcelain firing. Information is inadequate about the margi...
Technologies associated with using concentrated energy flows are increasingly used in industry due to the need to manufacture products made of hard alloys and other difficult-to-process materials. Thi...
This study investigates the effects of hollow structures, added by selective laser sintering (SLS), on the mechanical properties of a Co-Cr alloy for providing an optimal structural property to the fr...
The specimens produced using the 3D data of the dumbbell-shaped cylinders were divided into four groups based on the manufacturing method: Cast, Mill, SLS-solid, and SLS-hollow. Tensile tests were per...
The median elastic modulus was the largest in the Cast, followed by SLS-solid, Mill, and SLS-hollow, with no significant differences observed between all conditions. The median ultimate tensile streng...
With the addition of hollow structures, the elastic modulus decreased while the mechanical strength and proof stress remained high in SLS specimens. In addition, the ISO 22674 standard for dental meta...
The purpose of this study is to evaluate the mechanical properties and clinical fitness of 3D-printed bioglass porcelain fused to metal (PFM) dental crowns. To evaluate the mechanical properties, tens...