This study intended to evaluate the effect of digital veneering on four-point flexural strength (FS) and microtensile bond strength (μTBS) of veneered zirconia. Two different zirconia blocks, a lithiu...
The aim of this study was to compare composition, microstructure, and mechanical strength of current multilayer zirconia blanks....
Bar shaped specimens were made from several layers of multilayer zirconia blanks (Cercon ht ML, Dentsply Sirona, US; Katana Zirconia YML, Kuraray, J;SHOFU Disk ZR Lucent Supra, Shofu, J; priti multidi...
Mean flexural strength varied between 467.5 ± 97.5 MPa (top layer, IPS e.max ZirCAD Prime) and 898.0 ± 188.5 MPa (bottom layer, Cercon ht ML) with significant (p ≤ 0.055) differences between the indiv...
The investigated blanks differ predominantly in the intermediate layers. In addition to dimensioning of restorations, the milling position in the blanks must also be taken into account when using mult...
Effects of the aging process on the flexural strength of Y-TZP and different Y-PSZ ceramics of different thicknesses were investigated....
300 disc-shaped samples (12 mm diameter, 0.8 and 1.5 mm thicknesses) were made from 5 different zirconia materials 3Y-TZP LA, 4Y-PSZ, 5Y-PSZ, 3 + 5Y-PSZ and 4 + 5Y-PSZ. Experimental groups were artifi...
Statistically significant differences in flexural strength were observed among the materials and the material thicknesses (p < 0.05), while there were no significant differences among the aging times ...
Both material type and thickness significantly affect the flexural strength of zirconia ceramics, whereas aging time does not; thus, material selection and thickness are crucial considerations for cli...
To evaluate the flexural strength of digitally milled and printed denture base materials....
The materials tested were Lucitone 199 denture base disc (Dentsply Sirona), AvaDent denture base puck (AvaDent), KeyMill denture base disc (Keystone), Lucitone digital print denture base resin (Dentsp...
The milled materials exhibited higher flexural strength than the printed materials. Thermocycling and fatigue reduce the flexural strengths of printed and milled materials. The repaired groups exhibit...
The milled denture base materials showed higher flexural strength than the printed ones....
This study aimed to evaluate the impact of silver nanoparticles (AgNPs) on the flexural strength of feldspathic porcelain....
Eighty bar-shaped ceramic specimens were prepared in five groups, including a control group and four case groups containing 5, 10, 15, and 20% w/w of AgNPs. Each group consisted of 16 specimens. Silve...
The results implied that the average flexural strength of the samples in the control group was 90.97 MPa and for the experimental groups reinforced with 5, 10, 15, and 20% w/w of AgNPs were 89, 81, 76...
The addition of AgNPs with a certain amount (up to a concentration of 15% w/w) without reducing the flexural strength improves the antimicrobial properties of the materials used and ultimately improve...
The addition of AgNPs can improve the antimicrobial properties and suitability of the materials....
This study evaluated the effects of 3D-printing build orientation on accuracy, flexural modulus (FM), flexural strength (FS), and microhardness of selected, commercial 3D-printed provisional resins (3...
PMMA CAD/CAM provisional material (Vita Temp/Vita) served as Control. Four 3DRs (Cosmos-SLA/Yller, Cosmos-DLP/Yller, PriZma-Bioprov/Makertech, Nanolab/Wilcos) were used in three printing orientations ...
Except for Cosmos-DLP, the 90° orientation demonstrated the best overall accuracy in all dimensions evaluated. The overall accuracy of Cosmos-SLA was not significantly different from Control and highe...
In general, although build orientation did not influence microhardness results, the 90° -orientation resulted in the best overall accuracy for most 3DRs. After 1-year water storage, Cosmos-SLA printed...
The purpose of this study was to evaluate the flexural strength of heat polymerized denture base resin after thermocycling and different surface treatments done prior to repair or relining....
In this...
The values of average flexural strength of denture base resin measured were as follows: group I: 111.1 MPa, group II: 86.9 MPa, group III: 73.1 MPa, and group IV: 78.8 MPa. Groups II and IV possessed ...
The flexural strength of heat-polymerized denture base resin gets affected by different surface treatments done prior to relining procedures. Lowest flexural strength was obtained when treated with MM...
Prior to denture repair procedures, operators must choose the chemical surface treatment judiciously. It should not affect the mechanical properties such as flexural strength of denture base resins. R...
Different surface treatments have been applied to zirconia restorations in clinical practice to increase the bond strength between zirconia and cement, but their effect on flexural strength is unknown...
The purpose of this in vitro study was to evaluate the effect of different surface treatments before and after sintering on the flexural strength of zirconia....
Sixty disk-shaped specimens with an initial diameter of 18.6 ±0.1 mm and thickness of 2 ±0.1 mm were prepared from preshaded presintered 3Y-TZP blocks. The specimens were randomly divided into 3 group...
According to the XRD analysis, no monoclinic phases were determined on the surface of the presintered laser-treated specimens, but tetragonal phases were observed on the surface of the postsintered sp...
Postsintered specimens showed higher monoclinic content than presintered specimens. Laser-treated specimens showed the lowest biaxial flexural strength for both presintered and postsintered specimens....
Durability of provisional restoration is crucial for full-mouth reconstruction, which may be influenced by aging. This study evaluated the effect of aging on the flexural strength of provisional mater...
Bar specimens (2×2×25 mm) were fabricated from CAD-CAM [Vita CAD-Temp...
TCNG indicated the highest mean of σ (133.49 ±4.32), whereas VCNG indicated the lowest mean of σ (84.62 ±3.73) for nonaging. Upon aging process, TCAG revealed the highest mean of σ (123.11 ±4.55), whi...
The CAD-CAM provisional material possessed higher flexural strength than heat-polymerized PMMA and autopolymerized PMMA, which was suggested as a provisional material for rehabilitation. Aging reduced...
Glass-ceramics are often selected for use in dental restorations based upon advertised flexural strengths obtained from standardized tests on prefabricated specimens (bars and disks); these may not ac...
The purpose of this in vitro study was to determine and compare 4-point flexural strength, biaxial flexural strength, hardness, and crown failure loads for 3 commercially available glass-ceramics....
Specimens were pressed and prepared from 3 brands of glass-ceramics: Celtra (CEL), IPS e.max (EMA), and Lisi (LIS). Rectangular bars, circular disks, and fully contoured crowns were created (n=15 spec...
The general linear modeling revealed significant differences (P<.05) in the failure load for crown specimens (EMA>LIS>CEL), the 4-point flexural strength (EMA>LIS>CEL), and the biaxial flexural streng...
The 4-point flexural strength correlated significantly with crown failure load....