Aortic aneurysm endovascular treatment with the parallel graft technique from the aortic arch to the iliac axis.
Aged
Aged, 80 and over
Aortic Aneurysm, Abdominal
/ diagnostic imaging
Aortic Aneurysm, Thoracic
/ diagnostic imaging
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation
/ adverse effects
Endovascular Procedures
/ adverse effects
Female
Humans
Male
Postoperative Complications
/ etiology
Progression-Free Survival
Prosthesis Design
Retrospective Studies
Risk Factors
Stents
Time Factors
Journal
The Journal of cardiovascular surgery
ISSN: 1827-191X
Titre abrégé: J Cardiovasc Surg (Torino)
Pays: Italy
ID NLM: 0066127
Informations de publication
Date de publication:
Oct 2019
Oct 2019
Historique:
pubmed:
27
5
2017
medline:
18
12
2019
entrez:
27
5
2017
Statut:
ppublish
Résumé
The chimney technique has been developed for the treatment of complex aortic aneurysms. We analyzed the midterm to long-term outcomes of this approach from a single-center experience. From October 2008 to July 2016, 58 patients underwent endovascular aortic aneurysm repair using the chimney technique. Indications for treatment were thoracic aortic aneurysm (TAA) (N.=11), thoracoabdominal aortic aneurysm (TAAA) (N.=2), pararenal aortic aneurysm (PAAA) (N.=15), aortoiliac/isolated hypogastric artery aneurysm (N.=25), type I endoleak after previous TEVAR/EVAR (N.=4), proximal pseudoaneurysm after AAA open repair (N.=1). Elective (82.8%) and emergent (17.2%) procedures were included. The immediate technical success was 100%. Single, double and triple chimneys were performed in 46, 10, and two patients, respectively. Overall, 61 target vessels (three left common carotid arteries, eight left subclavian arteries, three celiac trunks, three superior mesenteric arteries, 19 renal arteries and 25 hypogastric arteries) were involved. Postoperative mortality was 0. No neurologic complications were registered. Primary patency rate of the chimney stent/stent graft was 98.3%. Low-flow type I endoleak was observed in four patients (6.9%). Postoperative chimney graft re-intervention rate was 1.7%. The median follow-up was 32±20 months (range 3-96 months). Overall estimated survival at 12, 50, and 80 months was 100%, 89% and 44%, respectively. Estimated freedom from endoleak at 1, 12, 24, and 36 months was 96.5%, 95%, 95%, and 93%, respectively. One hypogastric artery stent-graft occluded at the 3rd month of follow-up. No reintervention was performed. Our experience with the chimney technique for aortic aneurysms from the aortic arch to the iliac axis shows promising and durable mid- and long-term results. Endograft oversizing, associated with the chimney graft diameter and length choice remain fundamental to reduce the risk of the most frequent procedure complications: type I endoleak and CG occlusion. The wider use of this technique should be justified in patients considered at high risk for open repair and/or not suitable for the custom-made branched/fenestrated endografts.
Sections du résumé
BACKGROUND
BACKGROUND
The chimney technique has been developed for the treatment of complex aortic aneurysms. We analyzed the midterm to long-term outcomes of this approach from a single-center experience.
METHODS
METHODS
From October 2008 to July 2016, 58 patients underwent endovascular aortic aneurysm repair using the chimney technique. Indications for treatment were thoracic aortic aneurysm (TAA) (N.=11), thoracoabdominal aortic aneurysm (TAAA) (N.=2), pararenal aortic aneurysm (PAAA) (N.=15), aortoiliac/isolated hypogastric artery aneurysm (N.=25), type I endoleak after previous TEVAR/EVAR (N.=4), proximal pseudoaneurysm after AAA open repair (N.=1). Elective (82.8%) and emergent (17.2%) procedures were included.
RESULTS
RESULTS
The immediate technical success was 100%. Single, double and triple chimneys were performed in 46, 10, and two patients, respectively. Overall, 61 target vessels (three left common carotid arteries, eight left subclavian arteries, three celiac trunks, three superior mesenteric arteries, 19 renal arteries and 25 hypogastric arteries) were involved. Postoperative mortality was 0. No neurologic complications were registered. Primary patency rate of the chimney stent/stent graft was 98.3%. Low-flow type I endoleak was observed in four patients (6.9%). Postoperative chimney graft re-intervention rate was 1.7%. The median follow-up was 32±20 months (range 3-96 months). Overall estimated survival at 12, 50, and 80 months was 100%, 89% and 44%, respectively. Estimated freedom from endoleak at 1, 12, 24, and 36 months was 96.5%, 95%, 95%, and 93%, respectively. One hypogastric artery stent-graft occluded at the 3rd month of follow-up. No reintervention was performed.
CONCLUSIONS
CONCLUSIONS
Our experience with the chimney technique for aortic aneurysms from the aortic arch to the iliac axis shows promising and durable mid- and long-term results. Endograft oversizing, associated with the chimney graft diameter and length choice remain fundamental to reduce the risk of the most frequent procedure complications: type I endoleak and CG occlusion. The wider use of this technique should be justified in patients considered at high risk for open repair and/or not suitable for the custom-made branched/fenestrated endografts.
Identifiants
pubmed: 28548474
pii: S0021-9509.17.09899-8
doi: 10.23736/S0021-9509.17.09899-8
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM