High-density characterization of a localized reentry circuit occurred after AF ablation.
atrial fibrillation
atrial tachycardia
defragmentation
mapping
proarrhythmic
Journal
Pacing and clinical electrophysiology : PACE
ISSN: 1540-8159
Titre abrégé: Pacing Clin Electrophysiol
Pays: United States
ID NLM: 7803944
Informations de publication
Date de publication:
02 2019
02 2019
Historique:
received:
18
07
2018
revised:
04
09
2018
accepted:
05
09
2018
pubmed:
19
9
2018
medline:
31
12
2019
entrez:
19
9
2018
Statut:
ppublish
Résumé
We present the case of a localized reentry circuit that developed 24 h after radiofrequency ablation of atrial fibrillation (AF). The circuit was of interest because it overlapped with sites of previous defragmentation during AF. The circuit presented a small funnel that measured only 1.4 mm at its narrowest segment. Fractionated signals, which codify for slow conduction zones, corresponded to the isthmus site. Ablation at this site interrupted the atrial tachycardia.