Reversed Auxiliary Flow to Reduce Embolism Risk During TAVI: A Computational Simulation and Experimental Study.
Aorta
/ physiopathology
Aortic Valve
/ physiopathology
Blood Flow Velocity
Computer Simulation
Embolic Protection Devices
Heart Valve Prosthesis
Hemodynamics
Humans
Intracranial Embolism
/ etiology
Models, Anatomic
Models, Cardiovascular
Regional Blood Flow
Subclavian Artery
/ physiopathology
Transcatheter Aortic Valve Replacement
/ adverse effects
Aorta
Cerebral embolization
Computational fluid dynamics
Transcatheter aortic valve implantation
Journal
Cardiovascular engineering and technology
ISSN: 1869-4098
Titre abrégé: Cardiovasc Eng Technol
Pays: United States
ID NLM: 101531846
Informations de publication
Date de publication:
03 2019
03 2019
Historique:
received:
23
02
2018
accepted:
11
10
2018
pubmed:
21
10
2018
medline:
12
2
2020
entrez:
21
10
2018
Statut:
ppublish
Résumé
Endovascular treatments, such as transcatheter aortic valve implantation (TAVI), carry a risk of embolization due to debris dislodgement during various procedural steps. Although embolic filters are already available and marketed, mechanisms underlying cerebral embolism still need to be elucidated in order to further reduce cerebrovascular events. We propose an experimental framework with an in silico duplicate allowing release of particles at the level of the aortic valve and their subsequent capture in the supra-aortic branches, simulating embolization under constant inflow and controlled hemodynamic conditions. The effect of a simple flow modulation, consisting of an auxiliary constant flow via the right subclavian artery (RSA), on the amount of particle entering the brachiocephalic trunk was investigated. Preliminary computational fluid dynamics (CFD) simulations were performed in order to assess the minimum retrograde flow-rate from RSA required to deviate particles. Our results show that a constant reversed auxiliary flow of 0.5 L/min from the RSA under a constant inflow of 4 L/min from the ascending aorta is able to protect the brachiocephalic trunk from particle embolisms. Both computational and experimental results also demonstrate that the distribution of the bulk flow dictates the distribution of the particles along the aortic branches. This effect has also shown to be independent of release location and flow rate. The present study confirms that the integration of in vitro experiments and in silico analyses allows designing and benchmarking novel solutions for cerebral embolic protection during TAVI such as the proposed embo-deviation technique based on an auxiliary retrograde flow from the right subclavian artery.
Identifiants
pubmed: 30341729
doi: 10.1007/s13239-018-00386-y
pii: 10.1007/s13239-018-00386-y
doi:
Types de publication
Journal Article
Research Support, Non-U.S. Gov't
Video-Audio Media
Langues
eng
Sous-ensembles de citation
IM