Performance of two faecal immunochemical tests for the detection of advanced neoplasia at different positivity thresholds: a cross-sectional study of the Dutch national colorectal cancer screening programme.


Journal

The lancet. Gastroenterology & hepatology
ISSN: 2468-1253
Titre abrégé: Lancet Gastroenterol Hepatol
Pays: Netherlands
ID NLM: 101690683

Informations de publication

Date de publication:
02 2019
Historique:
received: 22 08 2018
revised: 23 09 2018
accepted: 24 09 2018
pubmed: 1 12 2018
medline: 6 5 2020
entrez: 1 12 2018
Statut: ppublish

Résumé

Faecal immunochemical tests (FITs) are recommended for colorectal cancer screening. Two frequently used FIT methods (FOB-Gold, Sentinel Diagnostics, Milan, Italy and OC-Sensor, Eiken Chemical, Tokyo, Japan) perform similarly in detecting advanced neoplasia (ie, colorectal cancer and advanced adenoma) at a fixed positivity cutoff for faecal haemoglobin concentration. It is unclear whether the performance of the two methods is also comparable at other thresholds. We compared the accuracy of the two assays in detecting advanced neoplasia across various thresholds. In a cross-sectional study in the Dutch national screening programme, individuals who were screening naive in 2016 (aged 55-75 years) living in the southwest region of the Netherlands were invited to use two different FIT assays on the same bowel movement. Eligible participants were randomly selected from municipal registers. Participants were referred for colonoscopy if either FIT assay result met the predefined positivity threshold (≥15 μg haemoglobin per g faeces). We compared the respective distributions of reported haemoglobin concentration and positivity rates with various FIT positivity thresholds. The performance of each FIT for identifying advanced neoplasia at colonoscopy in FIT-positive assays was compared with the area under the receiver operating characteristic curve. 21 078 (50·0%) of 42 179 invitees completed both FIT assays. The distribution of haemoglobin concentrations differed significantly between the two FITs (p<0·0001), with higher positivity rates for OC-Sensor at FIT thresholds of 5 and 10 μg haemoglobin per g faeces, similar positivity rates at 15 and 20 μg haemoglobin per g faeces, and higher rates for FOB-Gold at FIT thresholds of 25-150 μg haemoglobin per g faeces. 2046 (9·7%) of 21 078 participants had at least one FIT assay that was positive and of these, 1724 (84·3%) attended colonoscopy. The accuracy of results in individuals undergoing colonoscopy did not significantly differ between the FITs, with an area under the receiver operating characteristic curve of 0·675 (95% CI 0·649 to 0·702) for FOB-Gold and 0·686 (0·661 to 0·712) for OC-Sensor (p=0·40). At identical positivity rates, the positive predictive value of the two FIT assays was similar (difference varying from 0·5% [95% CI -2·6 to 3·7] at a positivity rate of 3·5% to 2·4% [-2·5 to 7·3] at a positivity rate of 2·0%). The two widely used FITs have significantly different distributions of reported haemoglobin concentration and yield different positivity rates at equal thresholds. However, they perform similarly in detecting advanced neoplasia at a preset positivity rate. When implementing either FIT in a screening programme, the desired positivity rate that identifies participants to be referred for colonoscopy should first be set, guided by available resources and feasibility. The Netherlands Organisation for Health Research and Development.

Sections du résumé

BACKGROUND
Faecal immunochemical tests (FITs) are recommended for colorectal cancer screening. Two frequently used FIT methods (FOB-Gold, Sentinel Diagnostics, Milan, Italy and OC-Sensor, Eiken Chemical, Tokyo, Japan) perform similarly in detecting advanced neoplasia (ie, colorectal cancer and advanced adenoma) at a fixed positivity cutoff for faecal haemoglobin concentration. It is unclear whether the performance of the two methods is also comparable at other thresholds. We compared the accuracy of the two assays in detecting advanced neoplasia across various thresholds.
METHODS
In a cross-sectional study in the Dutch national screening programme, individuals who were screening naive in 2016 (aged 55-75 years) living in the southwest region of the Netherlands were invited to use two different FIT assays on the same bowel movement. Eligible participants were randomly selected from municipal registers. Participants were referred for colonoscopy if either FIT assay result met the predefined positivity threshold (≥15 μg haemoglobin per g faeces). We compared the respective distributions of reported haemoglobin concentration and positivity rates with various FIT positivity thresholds. The performance of each FIT for identifying advanced neoplasia at colonoscopy in FIT-positive assays was compared with the area under the receiver operating characteristic curve.
FINDINGS
21 078 (50·0%) of 42 179 invitees completed both FIT assays. The distribution of haemoglobin concentrations differed significantly between the two FITs (p<0·0001), with higher positivity rates for OC-Sensor at FIT thresholds of 5 and 10 μg haemoglobin per g faeces, similar positivity rates at 15 and 20 μg haemoglobin per g faeces, and higher rates for FOB-Gold at FIT thresholds of 25-150 μg haemoglobin per g faeces. 2046 (9·7%) of 21 078 participants had at least one FIT assay that was positive and of these, 1724 (84·3%) attended colonoscopy. The accuracy of results in individuals undergoing colonoscopy did not significantly differ between the FITs, with an area under the receiver operating characteristic curve of 0·675 (95% CI 0·649 to 0·702) for FOB-Gold and 0·686 (0·661 to 0·712) for OC-Sensor (p=0·40). At identical positivity rates, the positive predictive value of the two FIT assays was similar (difference varying from 0·5% [95% CI -2·6 to 3·7] at a positivity rate of 3·5% to 2·4% [-2·5 to 7·3] at a positivity rate of 2·0%).
INTERPRETATION
The two widely used FITs have significantly different distributions of reported haemoglobin concentration and yield different positivity rates at equal thresholds. However, they perform similarly in detecting advanced neoplasia at a preset positivity rate. When implementing either FIT in a screening programme, the desired positivity rate that identifies participants to be referred for colonoscopy should first be set, guided by available resources and feasibility.
FUNDING
The Netherlands Organisation for Health Research and Development.

Identifiants

pubmed: 30497962
pii: S2468-1253(18)30319-4
doi: 10.1016/S2468-1253(18)30319-4
pii:
doi:

Substances chimiques

Hemoglobins 0

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

111-118

Commentaires et corrections

Type : CommentIn

Informations de copyright

Copyright © 2019 Elsevier Ltd. All rights reserved.

Auteurs

Clasine M de Klerk (CM)

Department of Gastroenterology and Hepatology, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands.

Els Wieten (E)

Department of Gastroenterology and Hepatology, Erasmus University Medical Center, Rotterdam, Netherlands.

Iris Lansdorp-Vogelaar (I)

Department of Public Health, Erasmus University Medical Center, Rotterdam, Netherlands.

Patrick M Bossuyt (PM)

Department of Clinical Epidemiology, Biostatistics and Bioinformatics, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands.

Manon Cw Spaander (MC)

Department of Gastroenterology and Hepatology, Erasmus University Medical Center, Rotterdam, Netherlands.

Evelien Dekker (E)

Department of Gastroenterology and Hepatology, Amsterdam University Medical Center, University of Amsterdam, Amsterdam, Netherlands. Electronic address: e.dekker@amc.uva.nl.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH