Automatically configuring the reference point method for automated multi-objective treatment planning.


Journal

Physics in medicine and biology
ISSN: 1361-6560
Titre abrégé: Phys Med Biol
Pays: England
ID NLM: 0401220

Informations de publication

Date de publication:
22 01 2019
Historique:
pubmed: 20 12 2018
medline: 19 12 2019
entrez: 20 12 2018
Statut: epublish

Résumé

Automated treatment planning algorithms have demonstrated capability in generating consistent and high-quality treatment plans. Their configuration (i.e. determining the algorithm's parameters), however, can be a labour-intensive and time-consuming trial-and-error procedure. Previously, we introduced the reference point method (RPM) for fast automated multi-objective treatment planning. The RPM generates a single Pareto optimal plan for each patient. When the RPM is configured appropriately, this plan has clinically favourable trade-offs between all plan objectives. This paper proposes a new procedure to automatically generate a single configuration of the RPM per tumour site. The procedure was tested for prostate cancer. Planning CT scans of 287 previously treated patients were included in a database, together with corresponding Pareto optimal plans generated using our clinically applied two-phase [Formula: see text]-constraint method (part of Erasmus-iCycle) for automated multi-objective treatment planning. The procedure developed acquires plan characteristics observed in a training set. Based on these, an RPM configuration is automatically generated according to user preferences which specify acceptable differences between training set plans and corresponding RPM generated plans. For example, compared to the training set plans, the RPM generated plans need to have similar PTV coverage, and preferably reduced high rectum dose while slight deteriorations in other objectives are allowed. Training sets of different sizes were tested, and the quality of the resulting RPM configurations was evaluated on the test set (subset of the database not used for training). Using the new procedure, an RPM configuration was generated for each training set. The quality of RPM generated plans was similar or slightly better than that of the corresponding test set plans. The proposed automated configuration procedure greatly reduces the manual configuration workload, and thereby improves the efficiency and effectiveness of an automated clinical treatment planning workflow.

Identifiants

pubmed: 30566906
doi: 10.1088/1361-6560/aaf9fe
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

035002

Auteurs

Rens van Haveren (R)

Department of Radiation Oncology, Erasmus MC Cancer Institute, University Medical Center Rotterdam, PO Box 2040, 3000 CA Rotterdam, The Netherlands.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH