Use of Eye Shields for Mohs Micrographic Surgery of the Eyelids and Periorbital Area.
Journal
Dermatologic surgery : official publication for American Society for Dermatologic Surgery [et al.]
ISSN: 1524-4725
Titre abrégé: Dermatol Surg
Pays: United States
ID NLM: 9504371
Informations de publication
Date de publication:
02 2019
02 2019
Historique:
pubmed:
5
1
2019
medline:
30
4
2019
entrez:
5
1
2019
Statut:
ppublish
Résumé
Internal eye shields are designed for use in periorbital procedures, but their use in Mohs micrographic surgery (MMS) of the eyelids has rarely been reported in the literature. The authors aim to discuss different types of internal eye shields as well as their indication, proper use, and potential complications. The authors performed a literature search on PubMed with the keywords "internal eye shield," "corneal shield," "scleral shield," and "periorbital Mohs micrographic surgery" with no restriction on publication time frame due to the scarcity of relevant literature. Experts seem to agree that use of eye shield for MMS of the eyelids is a reasonable measure to undertake to prevent operative injuries. Although either plastic or stainless steel eye shield can be used, plastic eye shields are often preferred and recommended in procedures where electrosurgical devices need to be used. Although the authors recommend the use of internal eye shields for MMS of the eyelids for preventing operative injuries, this recommendation (Grade C) is based on very limited evidence (Level 5). More research and higher-powered studies are needed for conclusive evidence and to establish clear guidelines for providers.
Sections du résumé
BACKGROUND
Internal eye shields are designed for use in periorbital procedures, but their use in Mohs micrographic surgery (MMS) of the eyelids has rarely been reported in the literature.
OBJECTIVE
The authors aim to discuss different types of internal eye shields as well as their indication, proper use, and potential complications.
MATERIALS AND METHODS
The authors performed a literature search on PubMed with the keywords "internal eye shield," "corneal shield," "scleral shield," and "periorbital Mohs micrographic surgery" with no restriction on publication time frame due to the scarcity of relevant literature.
RESULTS
Experts seem to agree that use of eye shield for MMS of the eyelids is a reasonable measure to undertake to prevent operative injuries. Although either plastic or stainless steel eye shield can be used, plastic eye shields are often preferred and recommended in procedures where electrosurgical devices need to be used.
CONCLUSION
Although the authors recommend the use of internal eye shields for MMS of the eyelids for preventing operative injuries, this recommendation (Grade C) is based on very limited evidence (Level 5). More research and higher-powered studies are needed for conclusive evidence and to establish clear guidelines for providers.
Identifiants
pubmed: 30608286
doi: 10.1097/DSS.0000000000001722
doi:
Types de publication
Journal Article
Review
Langues
eng
Sous-ensembles de citation
IM