Multi-observer contouring of male pelvic anatomy: Highly variable agreement across conventional and emerging structures of interest.
contouring
delineation
inter/intra-observer variability
prostate
Journal
Journal of medical imaging and radiation oncology
ISSN: 1754-9485
Titre abrégé: J Med Imaging Radiat Oncol
Pays: Australia
ID NLM: 101469340
Informations de publication
Date de publication:
Apr 2019
Apr 2019
Historique:
received:
05
06
2018
accepted:
27
11
2018
pubmed:
5
1
2019
medline:
14
8
2019
entrez:
5
1
2019
Statut:
ppublish
Résumé
This study quantified inter-observer contouring variations for multiple male pelvic structures, many of which are of emerging relevance for prostate cancer radiotherapy progression and toxicity response studies. Five prostate cancer patient datasets (CT and T2-weighted MR) were distributed to 13 observers for contouring. CT structures contoured included the clinical target volume (CTV), seminal vesicles, rectum, colon, bowel bag, bladder and peri-rectal space (PRS). MR contours included CTV, trigone, membranous urethra, penile bulb, neurovascular bundle and multiple pelvic floor muscles. Contouring variations were assessed using the intraclass correlation coefficient (ICC), Dice similarity coefficient (DSC), and multiple additional metrics. Clinical target volume (CT and MR), bladder, rectum and PRS contours showed excellent inter-observer agreement (median ICC = 0.97; 0.99; 1.00; 0.95; 0.90, DSC = 0.83 ± 0.05; 0.88 ± 0.05; 0.93 ± 0.03; 0.81 ± 0.07; 0.80 ± 0.06, respectively). Seminal vesicle contours were more variable (ICC = 0.75, DSC = 0.73 ± 0.14), while colon and bowel bag contoured volumes were consistent (ICC = 0.97; 0.97), but displayed poor overlap (DSC = 0.58 ± 0.22; 0.67 ± 0.21). Smaller MR structures showed significant inter-observer variations, with poor overlap for trigone, membranous urethra, penile bulb, and left and right neurovascular bundles (DSC = 0.44 ± 0.22; 0.41 ± 0.21; 0.66 ± 0.21; 0.16 ± 0.17; 0.15 ± 0.15). Pelvic floor muscles recorded moderate to strong inter-observer agreement (ICC = 0.50-0.97), although large outlier variations were observed. Inter-observer contouring variation was significant for multiple pelvic structures contoured on MR.
Identifiants
pubmed: 30609205
doi: 10.1111/1754-9485.12844
doi:
Types de publication
Journal Article
Langues
eng
Pagination
264-271Subventions
Organisme : NHMRC
ID : 1077788
Informations de copyright
© 2019 The Royal Australian and New Zealand College of Radiologists.