An analysis of the impact of fluid overload and fluid depletion for all-cause and cardiovascular mortality.
Aged
Cardiovascular Diseases
/ mortality
Dialysis Solutions
/ adverse effects
Female
Follow-Up Studies
Humans
Male
Middle Aged
Mortality
Prognosis
Proportional Hazards Models
Renal Dialysis
/ adverse effects
Retrospective Studies
Risk
Romania
/ epidemiology
Survival Analysis
Treatment Outcome
Water-Electrolyte Imbalance
/ etiology
cardiovascular
haemodialysis
myocardial infarction
prognosis
survival analysis
Journal
Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
ISSN: 1460-2385
Titre abrégé: Nephrol Dial Transplant
Pays: England
ID NLM: 8706402
Informations de publication
Date de publication:
01 08 2019
01 08 2019
Historique:
received:
27
06
2018
accepted:
15
11
2018
pubmed:
10
1
2019
medline:
7
5
2020
entrez:
10
1
2019
Statut:
ppublish
Résumé
Both baseline fluid overload (FO) and fluid depletion are associated with increased mortality risk and cardiovascular complications in haemodialysis patients. Fluid status may vary substantially over time, and this variability could also be associated with poor outcomes. In our retrospective cohort study, including 4114 haemodialysis patients from 34 Romanian dialysis units, we investigated both all-cause and cardiovascular mortality risk according to baseline pre- and post-dialysis volume status, changes in pre- and post-dialysis fluid status during follow-up (time-varying survival analysis), pre-post changes in volume status during dialysis and pre-dialysis fluid status variability during the first 6 months of evaluation. According to their pre-dialysis fluid status, patients were stratified in the following groups: normovolaemic with an absolute FO (AFO) compartment between -1.1 and 1.1 L, fluid depletion with an AFO below -1.1 L, moderate FO with an AFO compartment >1.1 but <2.5 L and severe FO with the AFO compartment >2.5 L. Baseline pre-dialysis FO and fluid depletion patients had a significantly elevated risk of all-cause mortality risk {hazard ratio [HR] 1.53 [95% confidence interval (CI) 1.22-1.93], HR 2.04 (95% CI 1.59-2.60) and HR 1.88 (95% CI 1.07-3.39) for moderate FO, severe FO and fluid depletion, respectively}. In contrast, post-dialysis fluid depletion was associated with better survival [HR 0.71 (95% CI 0.57-0.89)]. Similar results were found when using changes in pre- or post-dialysis fluid status during follow-up (time-varying values): FO patients had an increased risk of all-cause [moderate FO: HR 1.39 (95% CI 1.11-1.75); severe FO: HR 2.29 (95% CI 2.01-3.31] and cardiovascular (CV) mortality [moderate FO: HR 1.34 (95% CI 1.05-1.70); severe FO: HR 2.34 (95% CI 1.67-3.28)] as compared with normohydrated patients. Using pre-post changes in volume status during dialysis, we categorized the patients into six groups: Group 1, AFO <-1.1 L pre- and post-dialysis; Group 2, AFO between -1.1 and 1.1 L pre-dialysis and <-1.1 L post-dialysis (the reference group); Group 3, AFO between -1.1 and 1.1 L pre- and post-dialysis; Group 4, AFO >1.1 L pre-dialysis and <-1.1 L post-dialysis; Group 5, AFO >1.1 L pre-dialysis and between -1.1 and 1.1 L post-dialysis; Group 6, AFO >1.1 L pre- and post-dialysis. Using the baseline values, only patients in Groups 1, 5 and 6 maintained an increased risk for all-cause mortality as compared with the reference group. Additionally, CV mortality risk was significantly higher for patients in Groups 5 and 6. When we applied the time-varying analysis, patients in Groups 1, 5 and 6 had a significantly higher risk for both all-cause and CV mortality risk. In the last approach, the highest risk for the all-cause mortality outcome was observed for patients with high-amplitude fluctuation during the first 6 months of evaluation [HR 2.75 (95% CI 1.29-5.84)]. We reconfirm the association between baseline pre- and post-dialysis volume status and mortality in dialysis patients; additionally, we showed that greater fluid status variability is independently associated with higher mortality.
Sections du résumé
BACKGROUND
Both baseline fluid overload (FO) and fluid depletion are associated with increased mortality risk and cardiovascular complications in haemodialysis patients. Fluid status may vary substantially over time, and this variability could also be associated with poor outcomes.
METHODS
In our retrospective cohort study, including 4114 haemodialysis patients from 34 Romanian dialysis units, we investigated both all-cause and cardiovascular mortality risk according to baseline pre- and post-dialysis volume status, changes in pre- and post-dialysis fluid status during follow-up (time-varying survival analysis), pre-post changes in volume status during dialysis and pre-dialysis fluid status variability during the first 6 months of evaluation.
RESULTS
According to their pre-dialysis fluid status, patients were stratified in the following groups: normovolaemic with an absolute FO (AFO) compartment between -1.1 and 1.1 L, fluid depletion with an AFO below -1.1 L, moderate FO with an AFO compartment >1.1 but <2.5 L and severe FO with the AFO compartment >2.5 L. Baseline pre-dialysis FO and fluid depletion patients had a significantly elevated risk of all-cause mortality risk {hazard ratio [HR] 1.53 [95% confidence interval (CI) 1.22-1.93], HR 2.04 (95% CI 1.59-2.60) and HR 1.88 (95% CI 1.07-3.39) for moderate FO, severe FO and fluid depletion, respectively}. In contrast, post-dialysis fluid depletion was associated with better survival [HR 0.71 (95% CI 0.57-0.89)]. Similar results were found when using changes in pre- or post-dialysis fluid status during follow-up (time-varying values): FO patients had an increased risk of all-cause [moderate FO: HR 1.39 (95% CI 1.11-1.75); severe FO: HR 2.29 (95% CI 2.01-3.31] and cardiovascular (CV) mortality [moderate FO: HR 1.34 (95% CI 1.05-1.70); severe FO: HR 2.34 (95% CI 1.67-3.28)] as compared with normohydrated patients. Using pre-post changes in volume status during dialysis, we categorized the patients into six groups: Group 1, AFO <-1.1 L pre- and post-dialysis; Group 2, AFO between -1.1 and 1.1 L pre-dialysis and <-1.1 L post-dialysis (the reference group); Group 3, AFO between -1.1 and 1.1 L pre- and post-dialysis; Group 4, AFO >1.1 L pre-dialysis and <-1.1 L post-dialysis; Group 5, AFO >1.1 L pre-dialysis and between -1.1 and 1.1 L post-dialysis; Group 6, AFO >1.1 L pre- and post-dialysis. Using the baseline values, only patients in Groups 1, 5 and 6 maintained an increased risk for all-cause mortality as compared with the reference group. Additionally, CV mortality risk was significantly higher for patients in Groups 5 and 6. When we applied the time-varying analysis, patients in Groups 1, 5 and 6 had a significantly higher risk for both all-cause and CV mortality risk. In the last approach, the highest risk for the all-cause mortality outcome was observed for patients with high-amplitude fluctuation during the first 6 months of evaluation [HR 2.75 (95% CI 1.29-5.84)].
CONCLUSION
We reconfirm the association between baseline pre- and post-dialysis volume status and mortality in dialysis patients; additionally, we showed that greater fluid status variability is independently associated with higher mortality.
Identifiants
pubmed: 30624712
pii: 5280822
doi: 10.1093/ndt/gfy396
doi:
Substances chimiques
Dialysis Solutions
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
1385-1393Informations de copyright
© The Author(s) 2019. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.