Intra-arterial pulse wave analysis during thrombectomy for the assessment of collateral status - A feasibility study.
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2019
2019
Historique:
received:
15
05
2018
accepted:
26
12
2018
entrez:
11
1
2019
pubmed:
11
1
2019
medline:
23
10
2019
Statut:
epublish
Résumé
Knowledge of the collateralization of an occluded vessel is important for the risk-benefit analysis of difficult revascularization maneuvers during mechanical thrombectomy. If the territory behind a clot is well perfused, one could desist from performing a risky thrombectomy maneuver. The arterial pulse pressure curve may serve as an indicator for the collateralization of an occluded target vessel. We investigated the feasibility of arterial pulse measurements with a standard microcatheter. We measured the intra-arterial blood pressure proximal and distal to the clot in 40 thrombectomy maneuvers in a porcine stroke model. We used a microcatheter (Trevo Pro 18, Stryker, Kalamazoo, CA, USA), a pressure transducer (MEMSCAP SP844), an AdInstruments Powerlab 16/35 workstation, and LabChart 8 Software (AdInstruments, Dunedin, New Zealand). Median arterial blood pressure proximal and distal to the clot was 96.0 mmHg (IQR, 23.8 mmHg) and 47.5 mmHg (IQR, 43.5 mmHg), respectively (p < .001). The median difference between systolic maximum and diastolic minimum proximal and distal to the clot decreased significantly from 1.8 mmHg (IQR, 3.6 mmHg) to 0.0 mmHg (IQR, 0.5 mmHg) (p < .001). There was loss of the curve in 26 of 40 cases and loss of pressure in 23 of 40 cases (p = .008). There was no significant correlation between vessel diameter and either loss of the pulse pressure curve (p = .20) or overall pressure loss (p = .31). It is possible to measure the pulse pressure proximal and distal to the clot with a standard microcatheter used during mechanical thrombectomy.
Identifiants
pubmed: 30629721
doi: 10.1371/journal.pone.0210572
pii: PONE-D-18-10604
pmc: PMC6328207
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0210572Déclaration de conflit d'intérêts
I have read the journal's policy and the authors of this manuscript have the following competing interests: Martin Wiesmann has the following disclosures: grants: Stryker Neurovascular, Siemens Healthcare; personal fees: Stryker Neurovascular, Silkroad Medical, Siemens Healthcare, Bracco; non-financial support: Codman Neurovascular, Covidien, Abbott, St. Jude Medical, Phenox, Penumbra, Microvention/Terumo, B. Braun, Bayer, Acandis, ab medica. The other authors (JS, TS, FSM, HN, SH, AM, MK, and ON) have nothing to disclose. This does not alter our adherence to PLOS ONE policies on sharing data and materials.
Références
Neuroradiology. 2003 Jan;45(1):11-8
pubmed: 12525948
J Neuroradiol. 2016 Feb;43(1):1-5
pubmed: 26452610
J Neurointerv Surg. 2019 Jul;11(7):653-658
pubmed: 30530771
Stroke. 2013 Jun;44(6 Suppl 1):S7-S10
pubmed: 23709736
AJNR Am J Neuroradiol. 2015 Jun;36(6):1162-6
pubmed: 25678479
Can Assoc Radiol J. 2004 Dec;55(5):326-9
pubmed: 15646463
J Neurointerv Surg. 2016 Feb;8(2):197-202
pubmed: 25540180
J Neurointerv Surg. 2011 Mar;3(1):43-6
pubmed: 21990787
Thromb Haemost. 1997 Mar;77(3):510-5
pubmed: 9066003
AJNR Am J Neuroradiol. 2006 Jun-Jul;27(6):1357-61
pubmed: 16775297
J Neurointerv Surg. 2017 Mar;9(3):253-256
pubmed: 26975839
Clin Neuroradiol. 2018 Sep;28(3):327-338
pubmed: 28194477
Lancet Neurol. 2011 Oct;10(10):909-21
pubmed: 21939900
Comput Math Methods Med. 2017;2017:9295029
pubmed: 28373893
Interv Neuroradiol. 2016 Jun;22(3):325-32
pubmed: 26908591
Br J Radiol. 1999 May;72(857):448-51
pubmed: 10505007
AJNR Am J Neuroradiol. 2012 Feb;33(2):353-8
pubmed: 22173756
Lancet. 2016 Apr 23;387(10029):1723-31
pubmed: 26898852
J Neurosurg. 2005 May;102(5):870-8
pubmed: 15926712