Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
Publications dans "Mesure de la pression artérielle" :
Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
Publications dans "Mesure de la pression artérielle" :
Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
Publications dans "Mesure de la pression artérielle" :
Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Science, King's College London, King's Health Partners, London, United Kingdom.
World-Class Research Centre, Digital Biodesign and Personalized Healthcare, Sechenov University, Moscow, Russia.
Publications dans "Mesure de la pression artérielle" :
From the Institute for Stroke and Dementia Research (ISD), University Hospital (M.K.G., R.M., M.D.), and Graduate School for Systemic Neurosciences (M.K.G.), Ludwig-Maximilians-Universität LMU, Munich, Germany; Department of Biostatistics and Epidemiology, School of Public Health (D.G., E.E., C.L.M.S., A.D., I.T.), UK Dementia Research Institute (P.E., A.D.), Health Data Research-UK London (P.E.), and MRC-PHE Centre for Environment, School of Public Health (I.T.), Imperial College London; Centre for Prevention of Stroke and Dementia, Department of Clinical Neurosciences (A.J.S.W.), University of Oxford, UK; Department of Hygiene and Epidemiology (E.E., I.T.), University of Ioannina Medical School, Greece; National Institute for Health Research Imperial College Biomedical Research Centre (P.E.), London; Institute for Genetics and Molecular Medicine (C.L.M.S.), University of Edinburgh, UK; Munich Cluster for Systems Neurology (SyNergy) (M.D.); and German Centre for Neurodegenerative Diseases (DZNE) (M.D.), Munich, Germany.
Publications dans "Mesure de la pression artérielle" :
From the Institute for Stroke and Dementia Research (ISD), University Hospital (M.K.G., R.M., M.D.), and Graduate School for Systemic Neurosciences (M.K.G.), Ludwig-Maximilians-Universität LMU, Munich, Germany; Department of Biostatistics and Epidemiology, School of Public Health (D.G., E.E., C.L.M.S., A.D., I.T.), UK Dementia Research Institute (P.E., A.D.), Health Data Research-UK London (P.E.), and MRC-PHE Centre for Environment, School of Public Health (I.T.), Imperial College London; Centre for Prevention of Stroke and Dementia, Department of Clinical Neurosciences (A.J.S.W.), University of Oxford, UK; Department of Hygiene and Epidemiology (E.E., I.T.), University of Ioannina Medical School, Greece; National Institute for Health Research Imperial College Biomedical Research Centre (P.E.), London; Institute for Genetics and Molecular Medicine (C.L.M.S.), University of Edinburgh, UK; Munich Cluster for Systems Neurology (SyNergy) (M.D.); and German Centre for Neurodegenerative Diseases (DZNE) (M.D.), Munich, Germany.
Publications dans "Mesure de la pression artérielle" :
Department of Health, Exercise Science, and Recreation Management. Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, 231 Turner Center, University, MS, 38677, USA.
Publications dans "Mesure de la pression artérielle" :
Department of Health, Exercise Science, and Recreation Management. Kevser Ermin Applied Physiology Laboratory, The University of Mississippi, 231 Turner Center, University, MS, 38677, USA. jploenne@olemiss.edu.
Publications dans "Mesure de la pression artérielle" :
Automated cuff measured blood pressure (BP) is the global standard used for diagnosing hypertension, but there are concerns regarding the accuracy of the method. Individual variability in systolic BP ...
Blood pressure (BP) is the main biomarker for monitoring patients, as its lack of control above values considered normal is a modifiable risk factor for target organ damage. The aim of this study is t...
The Veterans Affairs (VA) medical centers provide care for millions of Veterans at high risk of cardiovascular disease and accurate BP measurement in this population is vital for optimal BP control. F...
Accurate arm circumference (AC) measurement is required for accurate blood pressure (BP) readings. Standards stipulate measuring arm circumference at the midpoint between the acromion process (AP) and...
To compare blood pressure (BP) in tonometric radial artery recordings during passive head-up tilt with ambulatory recordings and evaluate possible laboratory cutoff values for hypertension....
Laboratory BP and ambulatory BP were recorded in normotensive (n = 69), unmedicated hypertensive (n = 190), and medicated hypertensive (n = 151) subjects....
Mean age was 50.2 years, BMI 27.7 kg/m 2 , ambulatory daytime BP 139/87 mmHg, and 276 were male (65%). As supine-to-upright changes in SBP ranged from -52 to +30 mmHg, and in DBP from -21 to +32 mmHg,...
BP responses to upright posture were variable. When compared with ambulatory BP, mean(supine+upright) laboratory cutoff 136/82 mmHg classified 76% of subjects similarly as normotensive or hypertensive...
We used our established database to investigate predialysis blood pressure (BP) measurements at different time points....
Our study period spanned from 1 January 2019 to 31 December 2019. The different time points included: the long interdialytic interval versus the short interdialytic interval; different hemodialysis sh...
A total of 37 081 cases of hemodialysis therapies were included. After a long interdialytic interval, predialysis SBP and DBP were significantly elevated. Predialysis BP was 147.72/86.73 mmHg on Monda...
The long interdialytic interval and different hemodialysis shifts have a significant effect on predialysis BP in patients with hemodialysis. When interpreting BP in patients with hemodialysis, differe...
Hypertension is among the most common chronic conditions in older adults. Effective treatment exists, yet many older adults do not achieve recommended control of their blood pressure (BP). Self-measur...
Continuous, comfortable, convenient (C3), and accurate blood pressure (BP) measurement and monitoring are needed for early diagnosis of various cardiovascular diseases. To supplement the limited C3 BP...
Smart devices that are able to measure blood pressure (BP) are valuable for hypertension or heart failure management using digital technology. Data regarding their diagnostic accuracy in comparison to...
Therefore, 159 consecutive patients (84 male, 75 female, mean age 64.33 ± 16.14 years) performed observed single measurements with the smart device compared to auscultatory sphygmomanometry (n = 109) ...
The intraclass correlation coefficient (ICC) between the difference and the mean of the oscillometric Omron HeartGuide and the conventional method for the single measurement was calculated for both sy...
The Omron HeartGuide device provided comparable BP values to the standard devices for single and long-term measurements. The infrared smart device failed to acquire valid measurement data....
Beat-to-beat (B2B) variability in biomedical signals has been shown to have high diagnostic power in the treatment of various cardiovascular and autonomic disorders. In recent years, new techniques an...