Results for tricuspid valve surgery in adults with congenital heart disease other than Ebstein's anomaly†.
Adult with congenital heart disease
Atrial septal defect
Congenital heart disease
De Vega
Grown up congenital heart disease
Heart failure
Long-term outcome
Outcomes
Prosthetic ring
Surgery
Tetralogy of Fallot
Tricuspid valve
Valve repair
Journal
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
ISSN: 1873-734X
Titre abrégé: Eur J Cardiothorac Surg
Pays: Germany
ID NLM: 8804069
Informations de publication
Date de publication:
01 Oct 2019
01 Oct 2019
Historique:
received:
16
10
2018
revised:
25
01
2019
accepted:
03
02
2019
pubmed:
29
3
2019
medline:
28
10
2020
entrez:
29
3
2019
Statut:
ppublish
Résumé
Tricuspid valve (TV) surgery in the adult with congenital heart disease (ACHD) is a frequently performed procedure. The aim of this study was to analyse postoperative and medium-term outcomes. We conducted a single-centre retrospective study of patients with ACHD who underwent TV surgery (January 2000-December 2016); patients with Ebstein's anomalies were excluded. Operative and clinical records were reviewed. Outcomes considered were survival, grade of insufficiency/stenosis and TV reoperation at follow-up. A total of 128 patients with ACHD had TV surgery for functional regurgitation (n = 95), dysplasia (n = 23) and systemic TV (n = 10). Median age was 40.8 years [interquartile range (IQR) 25.3]; 55.5% were men. Preoperative regurgitation was classified as mild (n = 8), moderate (n = 47) and severe (n = 70). The TV was repaired in 109 as follows: ring annuloplasty (n = 43), de Vega annuloplasty (n = 29), Wooler annuloplasty (n = 13), commissural plasty (n = 9), Kay annuloplasty (n = 7) and others (n = 8). The TV was replaced in 19 patients with biological (n = 10) and mechanical (n = 9) prostheses. The median hospital stay was 12 days (IQR 10). The overall mortality rate was 8.6% (n = 11): 2 hospital deaths (1.6%) and 9 late deaths. Survival was 93% [95% confidence interval (CI) 85-97%] at 5 years and 83% (95% CI 70-91%) at 10 years. The median follow-up period was 4.95 years (IQR 7.7) with 1 TV reoperation. Echocardiographic assessment showed ≥moderate regurgitation in 34 (34.3%) patients. Suture plasty had a significantly higher incidence of TV regurgitation ≥moderate compared to ring annuloplasty (48.9% vs 26.3%; P = 0.033). TV surgery in the ACHD is frequently associated with other main procedures. Stabilizing the TV annulus with a prosthetic ring guarantees lower recurrence of moderate to severe regurgitation compared to suture plasty repair.
Identifiants
pubmed: 30919906
pii: 5421312
doi: 10.1093/ejcts/ezz093
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
706-713Informations de copyright
© The Author(s) 2019. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.